Width Measurements (width + measurement)

Distribution by Scientific Domains


Selected Abstracts


Altered volume and hemispheric asymmetry of the superficial cortical layers in the schizophrenia planum temporale

EUROPEAN JOURNAL OF NEUROSCIENCE, Issue 3 2009
John F. Smiley
Abstract In vivo structural MRI studies in schizophrenia auditory cerebral cortex have reported smaller volumes and, less consistently, have reported altered hemispheric asymmetry of volumes. We used autopsy brains from 19 schizophrenia and 18 nonpsychiatric male subjects to measure the volume asymmetry of the planum temporal (PT). We then used the most recently autopsied 11 schizophrenia and 10 nonpsychiatric brains to measure the widths and fractional volumes of the upper (I,III) and lower (IV,VI) layers. Measurements of whole PT gray matter volumes did not show significant changes in schizophrenia. Nevertheless, laminar volume measurements revealed that the upper layers of the PT comprise a smaller fraction of the total cortex in schizophrenia than in nonpsychiatric brains. Subdivision of the PT showed that this change was especially prominent caudally, beyond Heschl's gyrus, whereas similar but less pronounced changes were found in the rostral PT and Heschl's gyrus. Complementary measures of laminar widths showed that the altered fractional volume in the caudal left PT was due mainly to ,8% thinner upper layers. However, the caudal right PT had a different profile, with thicker lower layers and comparatively unchanged upper layers. Thus, in the present study, laminar measurements provided a more sensitive method for detecting changes than measurement of whole PT volumes. Besides findings in schizophrenia, our cortical width measurements revealed normal hemispheric asymmetries consistent with previous reports. In schizophrenia, the thinner upper layers of the caudal PT suggest disrupted corticocortical processing, possibly affecting the multisensory integration and phonetic processing of this region. [source]


A precise water displacement method for estimating egg volume

JOURNAL OF FIELD ORNITHOLOGY, Issue 2 2009
Scott A. Rush
ABSTRACT Relationships between egg volume and an array of life-history traits have been identified for many bird species. Despite the importance of egg volume and the need for precise and accurate measurements, egg volume is usually estimated using a mathematical model that incorporates length and width measurements along with a shape variable. We developed an instrument that provides precise estimates of egg volume and can be easily used in the field. Using Clapper Rail (Rallus longirostris) eggs, we compared egg volumes measured using our instrument with estimates based on linear measurements. We found our instrument to be both precise and accurate. Compared with a method based on linear measurements of eggs, use of our instrument reduced variation in egg volume estimates by 1.6 cm3, approximately 8% of the volume of a Clapper Rail's egg. Further advantages of our technique include ease of use, increased accuracy of field-based volume estimates, and increased resolution of variation in egg volume estimates. In addition, our technique does not require postdata collection processing time and did not influence hatching success. Also, for Clapper Rails and similar species, our technique can be combined with other techniques (e.g., egg flotation) so that both egg volume and embryonic stage can be estimated at the same time. SINOPSIS Las relaciones entre el volumen del huevo y una gran cantidad de caracteres en las historias de vida han sido identificadas para muchas especies de aves. A pesar de la importancia del volumen del huevo y la necesidad de medidas más precisas, el volumen del huevo es comúnmente estimado usando modelos matemáticos que incorporan medidas del largo, ancho y forma del huevo. Nosotros creamos un instrumento que proporciona estimativos precisos del volumen del huevo y puede ser fácilmente usado en el campo. Usando huevos de Rallus longirostris comparamos las medidas de los volúmenes de los huevos usando nuestro instrumento con estimados obtenidos mediante mediadas lineales. Encontramos que nuestro instrumento fue preciso. Comparado con métodos que se basan en medidas lineales de los huevos, el uso de nuestro instrumento reduce la variación de los estimativos del volumen de los huevos en 1.6 cm3, aproximadamente 8% del volumen de los huevos de Rallus longirostris. Ventajas adicionales de nuestra técnica incluye facilidades de uso, incremento en la precisión en los estimativos de volumen realizados en el campo y un incremento en la disminución de la variación de los estimativos del volumen del huevo. Adicionalmente, nuestra técnica no requiere tiempo de manejo después de la colección de los datos, y no afecta el éxito de eclosión. También, para Rallus longirostris y especies similares, nuestra técnica puede ser combinada con otras técnicas (e. g., flotación de los huevos) de tal forma que simultáneamente se puedan estimar el volumen del huevo y el estadio embrionario. [source]


Measuring egg size using digital photography: testing Hoyt's method using Florida Scrub-Jay eggs

JOURNAL OF FIELD ORNITHOLOGY, Issue 1 2007
Eli S. Bridge
ABSTRACT Egg volumes are most often estimated using a mathematical model that incorporates length and width measurements and a species-specific shape variable. Although adequate in many respects, this technique does not account for intraspecific variation in egg shape. We developed a computer-automated technique that uses calibrated digital photographs to render precise measurements of several egg-size parameters including length, width, volume, and surface area. The system extracts egg outlines from photographs, and divides each egg into latitudinal slices that are subsequently regarded as simple geometric shapes (cylinders or cone frustra) with volumes and surface areas that can be summed to generate size parameters for the entire egg. We tested this technique using 491 eggs from Florida Scrub-Jay (Aphelocoma coerulescens) nests and compared the resulting egg volumes with volumes calculated using the preeminent method of estimating volume from linear measurements. Our method was highly accurate, and differences between the volumes from our method and the alternative method were strongly associated with variation in egg shape. Advantages of our technique include decreased handling of eggs and increased accuracy. Software resources and additional information regarding the technique are available at http://www.archbold-station.org/abs/data/birddata/Bridge-JFO-eggsize.htm. SINOPSIS El volumen de los huevos comunmente es estimado utilizando un modelo matemático en donde se incorpora el ancho y el largo del huevo y la variable de la forma de este. Aunque es un método adecuado en muchos aspectos, esta técnica no toma enconsideracion las variaciones intraespecificas de la forma de los huevos. Desarrollamos una técnica automática con computadora, que usa fotografia digital calibrada para ofrecer medidas de los huevos incluyendo largo, ancho, volumen y área superficial. El sistema extrae parámetros de los huevos de fotografías y divide cada huevo en rebanadas latitudinales, que subsecuentemente son tomadas como formas geométricas (e.g., cilindros o conos) con volumenes y áreas superficiales, que a su vez pueden ser utilizadas para obtener el largo y el ancho. Pusimos a prueba esta técnica con 491 huevos del Azulejón (Aphelocoma coerulescens) y comparamos el volumen de los huevos obtenidos con el computador con volumenes calculados con el método usual de medidas lineales. Nuestro método fue preciso y las diferencias en los volumenes usando nuestro método y las del método clásico estuvieron asociadas a la variación en la forma de los huevos. Entre las ventajas de nuestra técnica encontramos una disminución en la manipulación de los huevos y un aumento en la presición de los datos tomados. Los recursos computacionales que se necesitan e información adicional sobre esta técnica se encuentra disponible en: http://www.archbold-station.org/abs/data/birddata/Bridge-JFO-eggsize.htm. [source]


Be/X-ray binary SXP6.85 undergoes large Type II outburst in the Small Magellanic Cloud

MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, Issue 3 2010
L. J. Townsend
ABSTRACT The Small Magellanic Cloud (SMC) Be/X-ray binary pulsar SXP6.85 = XTE J0103,728 underwent a large Type II outburst beginning on 2008 August 10. The source was consistently seen for the following 20 weeks (MJD = 54688,54830). We present X-ray timing and spectroscopic analysis of the source as a part of our ongoing Rossi X-ray Timing Explorer (RXTE) monitoring campaign and INTEGRAL key programme monitoring the SMC and 47 Tuc. A comparison with the Optical Gravitational Lensing Experiment (OGLE) III light curve of the Be counterpart shows the X-ray outbursts from this source coincide with times of optical maximum. We attribute this to the circumstellar disc increasing in size, causing mass accretion on to the neutron star. Ground based infrared photometry and H, spectroscopy obtained during the outburst are used as a measure of the size of the circumstellar disc and lend support to this picture. In addition, folded RXTE light curves seem to indicate complex changes in the geometry of the accretion regions on the surface of the neutron star, which may be indicative of an inhomogeneous density distribution in the circumstellar material causing a variable accretion rate on to the neutron star. Finally, the assumed inclination of the system and H, equivalent width measurements are used to make a simplistic estimate of the size of the circumstellar disc. [source]


A catalogue of absorption lines in eight Hubble Space Telescope/STIS E230M 1.0 < z < 1.7 quasar spectra,

MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, Issue 3 2007
N. Milutinovi
ABSTRACT We have produced a catalogue of line identifications and equivalent width measurements for all absorption features in eight ultraviolet echelle quasar spectra. These spectra were selected as having the highest signal-to-noise ratio among the Hubble Space Telescope/STIS spectra obtained with the E230M grating. We identify 56 metal-line systems towards the eight quasars, and present plots of detected transitions, aligned in velocity space. We found that about 1/4,1/3 of the features in the Ly, forest region, redward of the incidence of the Ly, forest, are metal lines. High-ionization transitions are common. At the redshift range we study, z < 1.7, we see both O vi and C iv in 88,90 per cent of the metal-line systems for which the spectra cover the expected wavelength. Si iii is seen in 58 per cent, while low-ionization absorption in C ii, Si ii and/or Al ii is detected in 50 per cent of the systems for which they are covered. This catalogue will facilitate future studies of the Ly, forest and of metal-line systems of various types. [source]


Large cava septi pellucidi in schizophrenic patients, alcoholics, head-traumatized, and normal individuals: morpholgical features and forensic implications.

ACTA NEUROPSYCHIATRICA, Issue 1 2006
A postmortem study
Background:, The enlarged cava septi pellucidi (CSP = 6 mm in length) have been reported as a reliable marker of an underlying neuropsychiatric disease or disorder. Differences in the dimensions of cava longer than 6 mm associated with a neuropsychiatric impairment could be of possible clinical and forensic significance. Methods:, We obtained 479 brains from autopsied persons (310 males and 169 females, aged 22,89 years) and observed that 110 brains (75 males and 35 females) had CSP, of which the length of CSP was equal to or longer than 6 mm on 69 (49 males and 20 females) of them. These cava were classified into four groups depending on the past medical histories of the autopsied person: five without neuropsychiatric history (asymptomatic CSP), 25 schizophrenic patients, 22 alcoholics, and 17 with a past head trauma (symptomatic CSP). Results:, The linear parameters of CSP (i.e. length, width) of the symptomatic and asymptomatic groups were measured and were statistically analyzed. Analysis revealed that the cava in the group of schizophrenic patients were significantly longer and wider. Conclusions:, Discriminant function analysis was used to derive a mathematical formula to classify CSP into one of the groups obtained based on width measurements of the cavum. [source]