Volume Estimates (volume + estimate)

Distribution by Scientific Domains


Selected Abstracts


The Relationship Between Self-Reported Drinking and BAC Level in Emergency Room Injury Cases: Is it a Straight Line?

ALCOHOLISM, Issue 6 2010
Jason Bond
Background:, While the validity of self-reported consumption based on blood alcohol concentration (BAC) has been found to be high in emergency room (ER) samples, little research exists on the estimated number of drinks consumed given a BAC level. Such data would be useful in establishing a dose,response relationship between drinking and risk (e.g., of injury) in those studies for which the number of drinks consumed is not available but BAC is. Methods:, Several methods were used to estimate the number of drinks consumed in the 6 hours prior to injury based on BAC obtained at the time of ER admission of n = 1,953 patients who self-reported any drinking 6 hours prior to their injury and who arrived to the ER within 6 hours of the event, from the merged Emergency Room Collaborative Alcohol Analysis Project (ERCAAP) and the World Health Organization Collaborative Study on Alcohol and Injury across 16 countries. Results:, The relationship between self-reported consumption and averaged BAC within each consumption level appeared to be fairly linear up to about 7 drinks and a BAC of approximately 100 mg/dl. Above about 7 reported drinks, BAC appeared to have no relationship with drinking, possibly representing longer consumption periods than only the 6 hours before injury for those reporting higher quantities consumed. Both the volume estimate from the bivariate BAC to self-report relationship as well as from a Widmark calculation using BAC and time from last drink to arrival to the ER indicated a somewhat weak relationship to actual number of self-reported drinks. Conclusions:, Future studies may benefit from investigating the factors suspected to be driving the weak relationships between these measures, including the actual time over which the reported alcohol was consumed and pattern of drinking over the consumption period. [source]


Thymic size in preterm neonates: a sonographic study

ACTA PAEDIATRICA, Issue 7 2003
DL Jeppesen
Aim: To assess the variation in size of the thymus in vivo in preterm neonates and to identify relations between thymic size and gestational age (GA), birthweight, occurrence of postnatal infections and maternal alcohol and tobacco intake during pregnancy. Methods: Eighty preterm neonates with a GA between 24 and 36 wk, and a birthweight between 490 and 4110 g were examined between days 0 and 19 after birth. The thymic size was assessed by sonography as a volume estimate, the so-called thymic index (Ti). The median Ti was 5.2 (1.2,17.9). Ti was positively correlated with birthweight and GA and negatively correlated with occurrence of postnatal infection (p < 0.01, p= 0.03, p= 0.05, R2= 0.68). A correlation between thymic size and maternal alcohol and tobacco intake was not demonstrated. Conclusion: It is possible to assess the size of the thymus by sonography in very low-birthweight and preterm neonates. A normal range for Ti in preterm neonates has been established. The sonographic method is a safe and effective technique for measuring the size of the thymus in preterm infants. [source]


The application of structured-light illumination microscopy to hydrocarbon-bearing fluid inclusions

GEOFLUIDS (ELECTRONIC), Issue 2 2008
N. J. F. BLAMEY
Abstract Structured-light illumination (SLI)-based microscopy offers geologists a new perspective for screening of hydrocarbon-bearing (HCFI) and small aqueous fluid inclusion (AFI) assemblages. This optical-sectioning technique provides rapid, confocal-like imaging, using relatively simple and inexpensive instrumentation. The 3D fluorescent images of HCFI planes and large single HCFIs permit the visualization of the relationships between HCFI assemblages, examination of HCFI morphology, and volume estimates of the fluorescent components within HCFIs. By the use of normal white light illumination, SLI image capture, and varying acquisition time it is also possible to image AFI because of the random movements of vapour bubbles within the inclusions. This allows the near-simultaneous visualization of hydrocarbon and AFI which is of significant importance for the study of sedimentary basins and petroleum reservoirs. SLI is a unique and accessible 3D petrographic tool, with practical advantages over conventional epifluorescence and confocal laser scanning microscopy. [source]


Volumetric analysis of extraction sockets using cone beam computed tomography: a pilot study on ex vivo jaw bone

JOURNAL OF CLINICAL PERIODONTOLOGY, Issue 11 2007
Jimoh Olubanwo Agbaje
Abstract Aim: The aim of this study was to determine the accuracy of volumetric analysis of extraction sockets using cone beam computed tomography (CBCT). Material and Methods: The volume of 40 dental alveoli in nine dry skull specimens (four mandibles and five maxillae) was determined by measuring the volume of the tooth socket impression using the water displacement technique. This was considered as the gold standard. Then, the tooth socket was scanned with CBCT and data were uploaded in the semi-automated Livewire® segmentation software. The software segments the tooth socket in consecutive 1 mm-thick two-dimensional slices. After segmentation, the total volume of the delineated socket was computed. The statistical difference between direct volumetric measurements and those obtained with CBCT imaging was assessed using the Student paired t -test. Result: The mean socket volume of the skull specimens was 227±91 mm3 when obtained by direct measurement and 225±90 mm3 when obtained by CBCT imaging. Student paired t -test showed no significant differences between both volume measurements (p>0.1). Conclusions: CBCT permits imaging of anatomical structures in three planes and allows for reliable volume estimates. The results should be verified in clinical circumstances and might have potential applicability for evaluation of extraction socket healing under different conditions. [source]


A precise water displacement method for estimating egg volume

JOURNAL OF FIELD ORNITHOLOGY, Issue 2 2009
Scott A. Rush
ABSTRACT Relationships between egg volume and an array of life-history traits have been identified for many bird species. Despite the importance of egg volume and the need for precise and accurate measurements, egg volume is usually estimated using a mathematical model that incorporates length and width measurements along with a shape variable. We developed an instrument that provides precise estimates of egg volume and can be easily used in the field. Using Clapper Rail (Rallus longirostris) eggs, we compared egg volumes measured using our instrument with estimates based on linear measurements. We found our instrument to be both precise and accurate. Compared with a method based on linear measurements of eggs, use of our instrument reduced variation in egg volume estimates by 1.6 cm3, approximately 8% of the volume of a Clapper Rail's egg. Further advantages of our technique include ease of use, increased accuracy of field-based volume estimates, and increased resolution of variation in egg volume estimates. In addition, our technique does not require postdata collection processing time and did not influence hatching success. Also, for Clapper Rails and similar species, our technique can be combined with other techniques (e.g., egg flotation) so that both egg volume and embryonic stage can be estimated at the same time. SINOPSIS Las relaciones entre el volumen del huevo y una gran cantidad de caracteres en las historias de vida han sido identificadas para muchas especies de aves. A pesar de la importancia del volumen del huevo y la necesidad de medidas más precisas, el volumen del huevo es comúnmente estimado usando modelos matemáticos que incorporan medidas del largo, ancho y forma del huevo. Nosotros creamos un instrumento que proporciona estimativos precisos del volumen del huevo y puede ser fácilmente usado en el campo. Usando huevos de Rallus longirostris comparamos las medidas de los volúmenes de los huevos usando nuestro instrumento con estimados obtenidos mediante mediadas lineales. Encontramos que nuestro instrumento fue preciso. Comparado con métodos que se basan en medidas lineales de los huevos, el uso de nuestro instrumento reduce la variación de los estimativos del volumen de los huevos en 1.6 cm3, aproximadamente 8% del volumen de los huevos de Rallus longirostris. Ventajas adicionales de nuestra técnica incluye facilidades de uso, incremento en la precisión en los estimativos de volumen realizados en el campo y un incremento en la disminución de la variación de los estimativos del volumen del huevo. Adicionalmente, nuestra técnica no requiere tiempo de manejo después de la colección de los datos, y no afecta el éxito de eclosión. También, para Rallus longirostris y especies similares, nuestra técnica puede ser combinada con otras técnicas (e. g., flotación de los huevos) de tal forma que simultáneamente se puedan estimar el volumen del huevo y el estadio embrionario. [source]