Intracardiac Ultrasound Detection of Thrombus on Transseptal Sheath: Incidence, Treatment, and Prevention

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 6 2005
KATANEH MALEKI M.D.
Background: Transseptal (TS) catheterization is used for left atrial (LA) ablation procedures and a major risk is thromboembolism. The purpose of this study was to assess (1) the value of intracardiac ultrasound (ICUS) monitoring during LA ablation procedures, and (2) a new technique to reduce the risk of thrombus formation. Methods and Results: One hundred and eighty consecutive patients underwent TS catheterization under ICUS guidance with two sheaths for atrial fibrillation ablation and one for other LA procedures. Group I included the initial 90 patients in whom TS sheaths were flushed with a standard 2 U/cc concentration of heparin; group II consisted of the next 90 patients in whom sheaths were flushed with 1,000 U/cc concentration. All patients received bolus and infusion of heparin to maintain ACT between 250,300 seconds. ICUS was monitored throughout. In group I, echodense material at the tip of the sheath consistent with thrombus was observed on ICUS in 8 of 90 patients (9%) within 5,15 minutes of entering the LA. In group II, only 1 of 90 patient (1%) demonstrated thrombus (P < 0.001). There were no significant clinical differences in group I patients with and without thrombus. In all nine patients, the clot was removed with vigorous aspiration. No patients suffered a neurological event. Conclusion: Thrombus formation on TS sheath, detected by ICUS, may be more common than expected despite adequate anticoagulation. Using a higher concentration of heparin for the TS system before deployment reduced the risk. The thrombus was retrieved with aspiration without the need to abort the procedure. [source]


Ultrasound detection of non-Hodgkin's lymphoma in three cynomolgus monkeys after renal transplantation and cyclosporine immunosuppression

JOURNAL OF MEDICAL PRIMATOLOGY, Issue 2 2001
Lorrie Gaschen
Purpose: To describe the early detection of non-Hodgkin's lymphoma (NHL) with ultrasound in three clinically normal cynomolgus monkeys post-renal transplantation and immunosuppression with cyclosporine. Materials and methods: The monkeys in this report were treated with cyclosporine (Neoral®) after receiving renal transplants. In addition to clinical and laboratory (hematology, serum chemistry) monitoring, renal allografts were monitored every 2 weeks with ultrasound and ultrasound-guided allograft biopsies were performed. Results: Enlarged renal hilar and mesenteric lymph nodes were detected with ultrasound in three monkeys on days 36, 49 and 134 post-transplantation. Sonographically the lymph nodes were inhomogeneous, of low echogenity and rounded. In two animals, the spleen was sonographically enlarged and inhomogeneous. All three monkeys were symptom-free at the time of ultrasound detection and NHL was diagnosed histologically. Conclusion: Ultrasound provides a rapid, non-invasive means of early detection of NHL in animal transplantation models prior to the onset of clinical symptoms of disease. [source]


Ultrasound detection of spontaneous hepato-cellular carcinomas in X/myc bitransgenic mice

LIVER INTERNATIONAL, Issue 6 2004
W. Mai
Abstract: Aims: To evaluate trans-abdominal ultrasound for the detection of Hepatocellular carcinoma (HCC) in a bitrasgenic murine (X/myc) model using a commercially available high-frequency ultrasound unit. Methods: Sixty-one female animals were included in this study. These animals were submitted to a single ultrasound examination of the liver under general anesthesia (isoflurane), and then euthanized. Results of ultrasound were compared with necropsy and histopathology. Results: The lesions demonstrated a fairly consistent aspect (oval- or round-shaped, well-defined hypoechoic homogeneous lesions), and lesions as small as 2 mm were identified. For detection of hepatic nodules per mouse the sensitivity was 75%, the specificity was 100% and the accuracy was 88.5%. For detection of hepatic focal lesions per lesions the overall sensitivity was 60%, the specificity was 97%, and the accuracy was 75.9%. Contrast-enhanced harmonic ultrasound imaging did not improve the identification of the lesions in our experimental conditions. Conclusion: High-frequency ultrasound appears to be an efficient tool allowing new possibilities to use this animal model and evaluate new therapies in longitudinal studies, which are much more powerful. [source]


Ultrasound detection of non-Hodgkin's lymphoma in three cynomolgus monkeys after renal transplantation and cyclosporine immunosuppression

JOURNAL OF MEDICAL PRIMATOLOGY, Issue 2 2001
Lorrie Gaschen
Purpose: To describe the early detection of non-Hodgkin's lymphoma (NHL) with ultrasound in three clinically normal cynomolgus monkeys post-renal transplantation and immunosuppression with cyclosporine. Materials and methods: The monkeys in this report were treated with cyclosporine (Neoral®) after receiving renal transplants. In addition to clinical and laboratory (hematology, serum chemistry) monitoring, renal allografts were monitored every 2 weeks with ultrasound and ultrasound-guided allograft biopsies were performed. Results: Enlarged renal hilar and mesenteric lymph nodes were detected with ultrasound in three monkeys on days 36, 49 and 134 post-transplantation. Sonographically the lymph nodes were inhomogeneous, of low echogenity and rounded. In two animals, the spleen was sonographically enlarged and inhomogeneous. All three monkeys were symptom-free at the time of ultrasound detection and NHL was diagnosed histologically. Conclusion: Ultrasound provides a rapid, non-invasive means of early detection of NHL in animal transplantation models prior to the onset of clinical symptoms of disease. [source]


Increased nuchal translucency in euploid fetuses,what should we be telling the parents?

PRENATAL DIAGNOSIS, Issue 2 2010
C.M. Bilardo
Abstract Nuchal translucency (NT) measurement between 11 and 14 weeks' gestation is an undisputed marker for aneuploidies. When conventional karyotyping is normal, enlarged NT is a strong marker for adverse pregnancy outcome, associated with miscarriage, intrauterine death, congenital heart defects, and numerous other structural defects and genetic syndromes. The risk of adverse outcome is proportional to the degree of NT enlargement. Although the majority of structural anomalies are amenable to ultrasound detection, unspecified genetic syndromes involving developmental delay may only emerge after birth. Concern over these prenatally undetectable conditions is a heavy burden for parents. However, following detection of enlarged NT the majority of babies with normal detailed ultrasound examination and echocardiography will have an uneventful outcome with no increased risk for developmental delay when compared to the general population. Counseling should emphasize this to help parents restore hope in normal pregnancy outcome and infant development. Copyright © 2010 John Wiley & Sons, Ltd. [source]


Evaluation of Membrane Oxygenators and Reservoirs in Terms of Capturing Gaseous Microemboli and Pressure Drops

ARTIFICIAL ORGANS, Issue 11 2009
Yulong Guan
Abstract An increasing amount of evidence points to cerebral embolization during cardiopulmonary bypass (CPB) as the principal etiologic factor of neurologic complications. In this study, the capability of capturing and classification of gaseous emboli and pressure drop of three different membrane oxygenators (Sorin Apex, Terumo Capiox SX25, Maquet QUADROX) were measured in a simulated adult model of CPB using a novel ultrasound detection and classification quantifier system. The circuit was primed with 1000 mL heparinized human packed red blood cells and 1000 mL lactated Ringer's solution (total volume 2000 mL, corrected hematocrit 26,28%). After the injection of 5 mL air into the venous line, an Emboli Detection and Classification Quantifier was used to simultaneously record microemboli counts at post-pump, post-oxygenator, and post-arterial filter sites. Trials were conducted at normothermic (35°C) and hypothermic (25°C) conditions. Pre-oxygenator and post-oxygenator pressure were recorded in real time and pressure drop was calculated. Maquet QUADROX membrane oxygenator has the lowest pressure drops compared to the other two oxygenators (P < 0.001). The comparison among the three oxygenators indicated better capability of capturing gaseous emboli with the Maquet QUADROX and Terumo Capiox SX25 membrane oxygenator and more emboli may pass through the Sorin Apex membrane oxygenator. Microemboli counts uniformly increased with hypothermic perfusion (25°C). Different types of oxygenators and reservoirs have different capability of capturing gaseous emboli and transmembrane pressure drop. Based on this investigation, Maquet QUADROX membrane oxygenator has the lowest pressure drop and better capability for capturing gaseous microemboli. [source]