Two-dimensional Ultrasound (two-dimensional + ultrasound)

Distribution by Scientific Domains


Selected Abstracts


Diagnostic performance of three-dimensional ultrasound extended imaging at scrotal mass lesions

INTERNATIONAL JOURNAL OF UROLOGY, Issue 11 2007
Salah Elwagdy
Objectives: High resolution two-dimensional ultrasound (2D US) difficulty in evaluation of some scrotal mass lesions is not frequent. The aim of the present study was to prospectively evaluate the diagnostic performance of three-dimensional ultrasound extended imaging (3D XI) in characterization of those lesions. Methods: The study protocol had the approval of the University's review board all participants' informed consents were obtained. The study included 28 selected patients (12 testicular and 16 para-testicular mass lesions) examined by 2D US and 3D XI applications including computed multi-slice view (MSV) and multi-resolution enhanced images (XI MR). Results were correlated with histopathological findings. Results: Two-dimensional ultrasound did not adequately characterize 28 patients out of 329 (8.5%). 3D XI interrogation was an easy procedure and distinctive of the pathological findings in 27 patients out of 28 (96.4%). The performance of XI MR with respect to characterization provided additional diagnostic information over MSV. Conclusions: The performance of 3D XI with respect to testicular mass characterization proved better than static 2D US. Subsequently, the results of this study suggest that the routine use of 2D US in diagnosis of scrotal mass lesions should preferably be upgraded to 3D XI methods. [source]


Comparison between three-dimensional volume-selective turbo spin-echo imaging and two-dimensional ultrasound for assessing carotid artery structure and function

JOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 3 2005
Lindsey A. Crowe PhD
Abstract Purpose To compare a volume-selective three-dimensional turbo spin echo (TSE) technique with ultrasound (US) for assessing carotid artery wall structure and function. Materials and Methods A three-dimensional volume-selective TSE technique was used to image the carotid artery in 10 healthy subjects and five hypertensive subjects (each of whom were scanned three times while they received different hypertension treatments). Lumen and wall area were measured on MR images. Two-dimensional US measurements of the intima-media thickness (IMT) and lumen diameter were taken in three orientations through a single cross section. The lumen area change over the cardiac cycle was used to determine distension. For validation, a Bland-Altman analysis was used to compare the vessel wall and lumen areas measured by three-dimensional MRI volumes with those obtained by US scans. Results Agreement between the two methods was found. The mean difference in distension between US and MRI was 1.2% (±5.1%). For the wall area measurements, good agreement was shown, but there was a systematic difference due to the visualization of the adventitia by MRI. Both techniques offer an easy way to objectively measure lumen indices. MRI can provide the complete circumference over the length of a vessel, while US is flexible and relatively inexpensive. The application of US is limited, however, when subjects are poorly echogenic. A difference between hypertensive and healthy subjects was found. Conclusion There was a good agreement between MRI and the clinically established two-dimensional US method. The MRI method has the advantage of providing increased vessel coverage, which permits one to assess localized abnormalities without assuming vessel uniformity. J. Magn. Reson. Imaging 2005;21:282,289. © 2005 Wiley-Liss, Inc. [source]


Three-dimensional sonographic volume measurement of the fetal spleen

JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH (ELECTRONIC), Issue 5 2007
Toshiyuki Hata
Abstract Aim:, The objective of this longitudinal study was to evaluate the growth of the fetal spleen in normal pregnancies, using three-dimensional ultrasound. Methods:, Three-dimensional sonographic examinations were performed on 14 appropriate-for-gestational-age fetuses. Fetal splenic volume was measured every 2,3 weeks after 20 weeks of gestational age until delivery. Results:, Curvilinear relationships were found between the gestational age and splenic volume (R2 = 80.2%, P < 0.0001), and normal ranges of splenic volume measurements for estimating the growth of the fetal spleen during normal pregnancy were generated. We found that the splenic volume calculation based on the equation for the volume of the ellipsoid by conventional two-dimensional ultrasound in previous investigations is about twice as large as that using three-dimensional ultrasound in our study, whereas the present data described in this study is quite comparable with previous data from an autopsy series. Conclusion:, Our findings suggest that the standard curve for the fetal splenic volume using three-dimensional ultrasound provides a superior means for evaluating the normal splenic growth in the fetus and for identifying splenic abnormalities in utero. However, the data and its interpretation in our study should be taken with some degree of caution because of the small number of subjects studied. Further studies involving a larger sample size would be needed to confirm these findings. [source]