Accelerating aging of zirconia femoral head implants: Change of surface structure and mechanical properties

JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, Issue 2 2007
S. Chowdhury
Abstract Recently, alternations of zirconia ceramic femoral heads of total hip prostheses during in vivo conditions have caused concern in the medical disciplines regarding phase transformation of zirconia prosthetic components. In this paper, we have investigated the mechanical and structural properties of different laboratory aged zirconia femoral heads and correlated changes in mechanical properties with the phase compositions of the sample. From laser microscope observation, cross-sectional Scanning electron microscopy imaging, and X-ray diffraction analysis on the surface of the zirconia femoral heads, we found monoclinic to tetragonal phase transformation in zirconia prostheses over time during the aging process in the laboratory. Mechanical properties, mainly hardness (H) and Young's modulus (E) values, were measured by nanoindentation technique on the surface of these implants. The results showed that both H and E values decreased with increased monoclinic phase in zirconia, thus confirming a phase transformation over time during aging. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006 [source]


Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements

JOURNAL OF ORTHOPAEDIC RESEARCH, Issue 2 2003
Christian Lhotka
Abstract Background: Metal-on-metal total hip prostheses will produce a certain amount of wear debris. This results in increased whole-blood metal levels, which may cause adverse effects. It is not known to what extent the problem has been overcome by advances in alloy technology. Methods: In 259 patients who with total hip replacement, blood cobalt and chromium concentrations were measured with atomic absorption spectrophotometry over a period of four years after arthroplasty. Of the patients enrolled in the study, 131 had been managed with a METASUL® cobalt-chromium alloy metal-on-metal bearing combination, while 128 had been given a SIKOMET®-SM21® cobalt-chromium alloy metal-on-metal combination. The control group consisted of 31 age- and gender-matched subjects. Results: Compared with the controls, all the patients had higher cobalt and chromium levels. Cobalt concentrations were up to 50 times higher, while chromium concentrations were up to 100 times higher. Conclusions: Both systems showed evidence, in the whole-blood samples, of wear debris production by the implants. Therefore, patients managed with metal-on-metal bearing combinations should be carefully monitored in order to ensure that any local or systemic complications are detected early on. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved. [source]


Wear Simulation of Alumina-on-Alumina Prosthetic Hip Joints Using a Multidirectional Motion Pin-on-Disk Device

JOURNAL OF THE AMERICAN CERAMIC SOCIETY, Issue 11 2002
Vesa Saikko
The wear of a state-of-the-art implant alumina against itself was studied with a circularly translating pin-on-disk (CTPOD) device, a wear simulator for prosthetic hip joint materials. The direction of sliding changed continually relative to the pin, preventing erroneous uniaxial grooving typical of ordinary pin-on-disk devices. The dominating wear mechanism was mild abrasion manifested as a relieflike surface, which agreed with clinical findings. The wear factor ranged from 1 × 10,8 to 6 × 10,8 mm3/(N·m). The CTPOD device, validated earlier for ultrahigh molecular weight polyethylene, was shown to be the first simple wear test device to produce wear similar to that known to occur clinically in alumina-on-alumina total hip prostheses. [source]


Cross-linked N-telopeptide of type I collagen (NTx) in urine as a predictor of periprosthetic osteolysis

JOURNAL OF ORTHOPAEDIC RESEARCH, Issue 7 2006
Thord von Schewelov
Abstract Periprosthetic osteolysis is often nonsymptomatic and hard to visualize by conventional radiography. Cross-linked N-telopeptide of type I collagen (NTx), a marker of osteoclast mediated bone resorption, has been suggested to evaluate local particulate-induced osteolysis in patients operated on with a total hip prosthesis. Urine specimens were sampled after hip joint replacement in 160 patients. NTx was analyzed by a commercially available ELISA kit. Osteolysis was identified in the acetabulum and confirmed at operation. Using analysis of covariance to correct for differences in age, gender, and time after operation, NTx (mean SD) was 36,±,12 BCE/nM creatinine in patients with osteolysis (n,=,33) and 27,±,13 BCE/nM creatinine in patients without osteolysis (n,=,127) (p,=,0.003). Eighteen hips of 38 (47%), demonstrating an annual wear of more than 0.2 mm and an NTx value above 29 BCE/nM creatinine, had been revised due to osteolysis. The osteolysis prevalence in this group was increased 10 times (CI 4-23, p,<,0.05). Indeed, NTx release and annual wear were both associated with increased prevalence of osteolysis, however, independently of each other. NTx seems a feasible marker of periprosthetic osteolysis. A preoperative baseline NTx level is likely needed for its use as a predictor of periprosthetic osteolysis in individual cases. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 24:1342,1348, 2006 [source]


Infection of a total hip prosthesis in a dog caused by Achromobacter(Alcaligenes) xylosoxidans

JOURNAL OF SMALL ANIMAL PRACTICE, Issue 12 2006
S. L. Girling
A four-year-old male, neutered Labrador retriever was presented with progressive left hindlimb lameness 10 months following total hip replacement. Radiography revealed changes consistent with infection and culture of joint fluid from the left coxofemoral joint revealed Achromobacter (Alcaligenes) xylosoxidans. The prosthesis was removed. Culture of the acetabular cup confirmed Achromobacter xylosoxidans. Achromobacter xylosoxidans is an uncommon but serious cause of nosocomial epidemics in hospitals for human beings. To the authors' knowledge, this is the first report of total hip prosthetic infection with Achromobacter xylosoxidans. Little is reported about its pathogenicity in human beings and the authors failed to retrieve any reports of its clinical significance in animals. [source]


Is Laterality Associated With a Higher Rate of Hip Arthroplasty on the Dominant Side?

ARTIFICIAL ORGANS, Issue 1 2008
Susanna Stea
Abstract:, The authors analyzed data collected by the Registry of the Orthopedic Prosthetic Implantology in Italy. They found a higher rate of total hip arthroplasty on the right side (58%) in comparison with the left side in patients affected by primary coxarthrosis. To test whether laterality was the cause of this, they checked the prevalence of the upper and lower limbs in 262 patients treated for monolateral total hip prosthesis. They found that the percentage of left-handed patients was very low (0.8,6.5%). The percentage of left-footed patients was, instead, 26.5% for power tasks. They observed that, while the rate of arthroplasties on the right side was similar to that of the left side (50.7 and 49.3%) in the right-footed patients, there was a clear-cut prevalence in the number of operations on the right hip (76.8%) in comparison to the left one (23.2%) in the left-footed patients. The authors suggested that, in left-footed patients, the right side was subjected to greater stress. [source]