Home About us Contact | |||
Steady-state Precession (steady-state + precession)
Selected AbstractsMR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequenceMAGNETIC RESONANCE IN MEDICINE, Issue 5 2002D. Germain Abstract MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal flip angle for the TrueFISP sequence was calculated for the best temperature sensitivity in the image signal from liver tissue, and verified from the images acquired during the thermocoagulation of excised pig liver. Factors influencing the accuracy of the measured temperatures are discussed. The TrueFISP results are compared to the calculated values of optimized SE and 3D GRE sequences. The accuracy of TrueFISP in the liver at 0.23 T, in imaging conditions used during thermocoagulation procedures, is estimated to be ±3.3°C for a voxel of 2.5 × 2.5 × 6 mm3 and acquisition time of 18 s. For the SE and GRE sequences, with similar resolution and somewhat longer imaging time, the uncertainty in the temperature is estimated to be larger by a factor of 2 and 1.2, respectively. Magn Reson Med 47:940,947, 2002. © 2002 Wiley-Liss, Inc. [source] Measurement of deep gray matter perfusion using a segmented true,fast imaging with steady-state precession (True-FISP) arterial spin-labeling (ASL) method at 3TJOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 6 2009Elan J. Grossman MS Abstract Purpose To study the feasibility of using the MRI technique of segmented true,fast imaging with steady-state precession arterial spin-labeling (True-FISP ASL) for the noninvasive measurement and quantification of local perfusion in cerebral deep gray matter at 3T. Materials and Methods A flow-sensitive alternating inversion-recovery (FAIR) ASL perfusion preparation was used in which the echo-planar imaging (EPI) readout was replaced with a segmented True-FISP data acquisition strategy. The absolute perfusion for six selected regions of deep gray matter (left and right thalamus, putamen, and caudate) were calculated in 11 healthy human subjects (six male, five female; mean age = 35.5 years ± 9.9). Results Preliminary measurements of the average absolute perfusion values at the six selected regions of deep gray matter are in agreement with published values for mean absolute cerebral blood flow (CBF) baselines acquired from healthy volunteers using positron emission tomography (PET). Conclusion Segmented True-FISP ASL is a practical and quantitative technique suitable to measure local tissue perfusion in cerebral deep gray matter at a high spatial resolution without the susceptibility artifacts commonly associated with EPI-based methods of ASL. J. Magn. Reson. Imaging 2009;29:1425,1431. © 2009 Wiley-Liss, Inc. [source] Image-guided and -monitored renal artery stenting using only MRIJOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 5 2006Daniel R. Elgort PhD Abstract Purpose To demonstrate the ability of a unique interventional MR system to be used safely and effectively as the only imaging modality for all phases of MR-guided stent-supported angioplasty. Materials and Methods An experimental disease model of renal stenosis was created in six pigs. An interventional MR system, which employed previously reported tools for real-time catheter tracking with automated scan-plane positioning, adaptive image parameters, and radial true,FISP imaging with steady-state precession (True-FISP) imaging coupled with a high-speed reconstruction technique, was then used to guide all phases of the intervention, including: guidewire and catheter insertion, stent deployment, and confirmation of therapeutic success. Pre- and postprocedural X-ray imaging was used as a gold standard to validate the experimental results. Results All of the stent-supported angioplasty interventions were a technical success and were performed without complications. The average postoperative residual stenosis was 14.9%. The image guidance enabled the stents to be deployed with an accuracy of 0.98 ± 0.69 mm. Additionally, using this interventional MRI system to guide renal artery stenting significantly reduces the procedure time, as compared to using X-ray fluoroscopy. Conclusion This study has clearly demonstrated the first successful treatment of renal artery stenting in an experimental animal model solely under MRI guidance and monitoring. J. Magn. Reson. Imaging 2006. © 2006 Wiley-Liss, Inc. [source] Comparison of relative forced expiratory volume of one second with dynamic magnetic resonance imaging parameters in healthy subjects and patients with lung cancer,JOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 3 2005Christian Plathow MD Abstract Purpose To assess relative forced expiratory volume in one second (FEV1/vital capacity (VC)) in healthy subjects and patients with a lung tumor using dynamic magnetic resonance imaging (dMRI) parameters. Materials and Methods In 15 healthy volunteers and 31 patients with a non-small-cell lung carcinoma stage I (NSCLC I), diaphragmatic length change (LE1) and craniocaudal (CC) intrathoracic distance change within one second from maximal inspiration (DE1) were divided by total length change (LEtotal, DEtotal) as a surrogate of spirometric FEV1/VC using a true fast imaging with steady-state precession (trueFISP) sequence (TE/TR = 1.7/37.3 msec, temporal resolution = 3 images/second). Influence of tumor localization was examined. Results In healthy volunteers FEV1/VC showed a highly significant correlation with LE1/LEtotal and DE1/DEtotal (r > 0.9, P < 0.01). In stage IB tumor patients, comparing tumor-bearing with the non-tumor-bearing hemithorax, there was a significant difference in tumors of the middle (LE1/LEtotal = 0.63 ± 0.05 vs. 0.73 ± 0.04, DE1/DEtotal = 0.66 ± 0.05 vs. 0.72 ± 0.04; P < 0.05) and lower (P < 0.05) lung region. Stage IA tumor patients showed no significant differences with regard to healthy subjects. Conclusion dMRI is a simple noninvasive method to locally determine LE1/LEtotal and DE1/DEtotal as a surrogate of FEV1/VC in volunteers and patients. Tumors of the middle and lower lung regions have a significant influence on these MRI parameters. J. Magn. Reson. Imaging 2005;21:212,218. © 2005 Wiley-Liss, Inc. [source] 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteriesMAGNETIC RESONANCE IN MEDICINE, Issue 3 2001Vibhas S. Deshpande Abstract The purpose of this work was to develop an ECG-triggered, segmented 3D true-FISP (fast imaging with steady-state precession) technique to improve the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of breath-hold coronary artery imaging. The major task was to optimize an appropriate magnetization preparation scheme to permit saturation of the epicardial fat signal. An ,/2 preparation pulse was used to speed up the approach to steady-state following a frequency-selective fat-saturation pulse in each heartbeat. The application of dummy cycles was found to reduce the oscillation of the magnetization during data acquisition. The fat saturation and magnetization preparation scheme was validated with simulations and phantom studies. Volunteer studies demonstrated substantially increased SNR (55%) and CNR (178%) for coronary arteries compared to FLASH (fast low-angle shot) with the same imaging time. In conclusion, true-FISP is a promising technique for coronary artery imaging. Magn Reson Med 46:494,502, 2001. © 2001 Wiley-Liss, Inc. [source] |