Home About us Contact | |||
Simple Operation (simple + operation)
Selected AbstractsBioprocesses for the removal of nitrogen oxides from polluted airJOURNAL OF CHEMICAL TECHNOLOGY & BIOTECHNOLOGY, Issue 5 2005Yaomin Jin Abstract Nitrogen oxides (NOx) of environmental concern are nitrogen monoxide (NO) and nitrogen dioxide (NO2). They are hazardous air pollutants that lead to the formation of acid rain and tropospheric ozone. Both pollutants are usually present simultaneously and are, therefore, called NOx. Another compound is N2O which is found in the stratosphere where it plays a role in the greenhouse effect. Concern for environmental and health issues coupled with stringent NOx emission standards generates a need for the development of efficient low-cost NOx abatement technologies. Under such circumstances, it becomes mandatory for each NOx-emitting industry or facility to opt for proper NOx control measures. Several techniques are available to control NOx emissions: selective catalytic reduction (SCR), selective non-catalytic reduction (SNCR), adsorption, scrubbing, and biological methods. Each process offers specific advantages and limitations. Since bioprocesses present many advantages over conventional technologies for flue gas cleaning, a lot of interest has recently been shown for these processes. This article reviews the major characteristics of conventional non-biological technologies and recent advances in the biological removal of NOx from flue gases based on the catalytic activity of either eucaryotes or procaryotes, ie nitrification, denitrification, the use of microalgae, and a combined physicochemical and biological process (BioDeNOx). Relatively uncomplicated design and simple operation and maintenance requirements make biological removal a good option for the control of NOx emissions in stationary sources. Copyright © 2005 Society of Chemical Industry [source] Recovery of lipase by adsorption at the n -hexadecane,water interfaceJOURNAL OF CHEMICAL TECHNOLOGY & BIOTECHNOLOGY, Issue 11 2003Hui-Min Wang Abstract A novel separation process based on the hydrophobic adsorption at the n -hexadecane,water interface was developed for the recovery of Acinetobacter radioresistens lipase from a pre-treated fermentation broth. In a mixture containing water, lipase and n -hexadecane, a water-in-oil emulsion was formed when the n -hexadecane-to-water ratio (o/w ratio) was larger than 3, and a large amount of lipase was found to be adsorbed at the interface. Compared with the oil-in-water emulsion (occurring when o/w ratio < 3), the water-in-oil emulsion generated smaller droplets and larger interfacial area, and was more stable. The harvested emulsion phase could be centrifuged to give an aqueous, concentrated lipase solution. Adsorption of lipase at the interface could be described by the Langmuir isotherm. For lipase concentrations ranging from 8.4 to 87.2 U cm,3, a single-stage adsorption resulted in a six- to four-fold concentration and 16,45% activity recovery, where lipase concentration was the dominant factor. A method using data from a single-stage adsorption to predict multiple-stage operation was described, and the agreement between the experimental and the predicted results was good. To improve the enzyme recovery, a multiple-run adsorption process was proposed. The use of salts enhanced the hydrophobic interaction between lipase and n -hexadecane. Advantages of the proposed process include simple operation, low operational cost, environmentally friendly, no requirement for pre-concentration of the enzyme solution, and negligible enzyme denaturation. Copyright © 2003 Society of Chemical Industry [source] Analysis of an antibody pharmaceutical, tocilizumab, by capillary electrophoresis using a carboxylated capillaryJOURNAL OF SEPARATION SCIENCE, JSS, Issue 5 2008Atsushi Taga Abstract Antibody pharmaceuticals are becoming more and more prevalent due to their excellent effectiveness in clinical medications, and are expected to allow tailor-made medical treatment for rheumatic diseases, immunosuppression in cardiac transplantation, and cancer. Antibody-type pharmaceuticals of immunoglobulin G (IgG) commonly have N -glycosylated carbohydrate chains attached to heavy chains. The carbohydrate chains play important roles in the effectiveness of antibodies. Therefore evaluation of a glycosylated species is important in the first step of quality control of antibody pharmaceuticals. In the present work, we examined capillary electrophoresis with a newly developed, chemically modified capillary, the inner surface of which is modified with carboxyl groups, for evaluation of IgG molecular species which have carbohydrate chains; tocilizumab was used as a model. The analytical system developed in the present study is useful for determining the content of non-glycosylated peptides. In the analysis of tocilizumab, the ratio of non-glycosylated peptide was estimated to be 1.23% with a relative standard deviation of 3.05%. The method affords high reproducibility with simple operation, and analysis can be completed within 6 min. [source] Protein thermal stability and phospholipid,protein interaction investigated by capillary isoelectric focusing with whole column imaging detectionJOURNAL OF SEPARATION SCIENCE, JSS, Issue 7 2006Tao Bo Abstract CIEF with whole column imaging detection (WCID) is an attractive technique for studying protein reaction and protein,ligand interaction due to its fast separation, simple operation, and high efficiency. In this study, two interesting applications by the CIEF-WCID were developed, involving the study of protein thermal stability and phospholipid,protein interaction. Four proteins (,-lactoglobulin B, trypsin inhibitor, phosphorylase b, and trypsinogen) with different pI, and two types of phospholipids, including phosphatidylcholine (PC) and phosphatidylserine (PS), were used for this purpose. First, the altered CIEF profiles of four proteins were exhibited due to conformational changes resulting from protein denaturation induced by a high incubation temperature at 60°C. It was demonstrated that the addition of a zwitterionic phospholipid (PC) played a crucial role in the thermal stability of targeted proteins, especially for trypsin inhibitor whose thermal stability was promoted with the addition of the PC vesicles at 60°C. Second, the zwitterionic (PC) and acidic (PS) phospholipids displayed completely different interactions with the proteins. The addition of PS vesicles modified the zwitterionic phospholipids to carry negative charges, which correspondingly changed the interaction between the phospholipid and the protein. Our study demonstrates that the CIEF-WCID is a powerful approach to study protein reaction and protein,ligand interaction with high efficiency, high selectivity, and fast separation. [source] The XMaS beamline at ESRF: instrumental developments and high-resolution diffraction studiesJOURNAL OF SYNCHROTRON RADIATION, Issue 6 2001S. D. Brown The beamline, which is situated on a bending magnet at ESRF, comprises a unique combination of instrumentation for high-resolution and magnetic single-crystal diffraction. White-beam operation is possible, as well as focused and unfocused monochromatic modes. In addition to an eleven-axis Huber diffractometer, which facilitates simple operation in both vertical and horizontal scattering geometries, there is an in-vacuum polarization analyser and slit system, mirrors for harmonic rejection, sub 4.2,K and 1,Tesla magnetic field sample environment, plus a diamond phase plate for polarization conditioning. The instrumentation developed specifically for this beamline is described, and its use illustrated by recent scientific results. [source] Flow-injection,chemiluminescence method for the determination of penicillin G potassiumLUMINESCENCE: THE JOURNAL OF BIOLOGICAL AND CHEMICAL LUMINESCENCE, Issue 4-5 2005Wei Cao Abstract The degradation product of penicillin G potassium can react with potassium permanganate in acidic medium and produce chemiluminescence, which is greatly enhanced by formaldehyde. The optimum conditions for this chemiluminescent reaction were studied in detail using a flow-injection system. The experiments indicated that under optimum conditions, the chemiluminescence intensity was linearly related to the concentration of penicillin G potassium within the range 1.0 × 10,7,1.0 × 10,5 g/mL, with a detection limit (3,) of 7 × 10,8 g/mL. The relative standard deviation was 1.0% for 4.0 × 10,7 g/mL penicillin G potassium solution (n = 11). This method has the advantages of simple operation, fast response and high sensitivity. The method was successfully applied to the analysis of penicillin G potassium in raw medicines. Copyright © 2005 John Wiley & Sons, Ltd. [source] An integrated simultaneous distillation,extraction apparatus for the extraction of essential oils from herb materials and its application in Flos MagnoliaeBIOMEDICAL CHROMATOGRAPHY, Issue 3 2010Yuhui Wei Abstract A large number of herb materials contain essential oils with extensive bioactivities. In this work, an integrated simultaneous distillation,extraction (ISDE) apparatus was developed. To demonstrate its feasibility, the performance of ISDE was evaluated for the extraction of essential oil from Flos Magnoliae and compared with conventional techniques including steam distillation (SD) and simultaneous distillation,extraction (SDE). According to the product yield, the time consumed and the composition of oil, the essential oils isolated by ISDE were better than that obtained by SD and similar to those obtained by SDE. ISDE was also better than SDE due to its simple operation and lower consumption of energy and organic solvent. Copyright © 2009 John Wiley & Sons, Ltd. [source] Samarium-promoted Chemoselective Reduction of Aromatic Nitro Compounds in Ionic LiquidCHINESE JOURNAL OF CHEMISTRY, Issue 9 2002Xing-Liaiig Zheng Abstract The differently substituted aromatic nitro compounds were chemoselectively reduced by Sm/HOAc system in an ionic liquid medium to afford aromatic amines. Under these conditions the other substituents, such as -X, -CHO, -COOH, -CN, -NHTos and -alkyl, remained intact. The notable advantages of this reaction are its mild conditions, simple operation, short reaction time, high yields and easy recycling of ionic liquid. [source] |