Signal Acquisition (signal + acquisition)

Distribution by Scientific Domains


Selected Abstracts


Multichannel surface electromyography in ergonomics: Potentialities and limits

HUMAN FACTORS AND ERGONOMICS IN MANUFACTURING & SERVICE INDUSTRIES, Issue 4 2010
Marco Gazzoni
Abstract The prevention of work-related musculoskeletal disorders is one of the main goals in ergonomics. Among others, surface electromyography (sEMG) is an important tool for the evaluation of risks related to work activity. Three main issues have been approached in ergonomics via sEMG: 1) the analysis of muscle activation, 2) the analysis of exerted forces and torques, and 3) the analysis of muscle fatigue. Many studies have been carried out in static conditions. In ergonomics, however, it is more relevant to study muscle activity and fatigue during real tasks that are, in general, dynamic. From isometric to dynamic contractions, the complexity of the interpretation of sEMG signals increases considerably. Changes in sEMG signals are related to the continuous modifications in force output, muscle fiber length, and relative position of surface electrodes and sources. To increase the reliability of the information extracted from sEMG, multichannel detection systems have been applied, showing the possibility of overcoming some limits of the standard technique. Some illustrative laboratory and field studies are reported in this work to illustrate the potentialities and the open problems in the use of multichannel sEMG in ergonomics. Case 1 is a laboratory study investigating the myoelectric manifestations of fatigue in the biceps brachii (BB) during dynamic elbow flexion/extension. Case 2 is a laboratory study investigating the myoelectric manifestations of fatigue during a repetitive lifting task. Case 3 is a field study, carried out in an automotive plant, investigating muscle activation during the welding of a car door. Many factors play a leading role in the correct interpretation of information provided by sEMG. Even though multichannel sEMG provides information able to improve the estimation of force and/or fatigue during working tasks, many problems related to the signal acquisition and interpretation are still open. Further improvements are necessary to develop multichannel sEMG into an effective tool supporting other methodologies for the evaluation of work-related risks. © 2010 Wiley Periodicals, Inc. [source]


ACE4k: An analog I/O 64×64 visual microprocessor chip with 7-bit analog accuracy

INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, Issue 2-3 2002
G. Liñán
Abstract This paper describes a full-custom mixed-signal chip which embeds distributed optical signal acquisition, digitally-programmable analog parallel processing, and distributed image memory cache on a common silicon substrate. This chip, designed in a 0.5 µm standard CMOS technology contains around 1.000.000 transistors, of which operate in analog mode; it is hence one the most complex mixed-signal chip reported to now. Chip functional features are: local interactions, spatial-invariant array architecture; programmable local interactions among cells; randomly-selectable memory of instructions (elementary instructions are defined by specific values of the cell local interactions); random storage/retrieval of intermediate images; capability to complete algorithmic image processing tasks controlled by the user-selected stored instructions and interacting with the cache memory, etc. Thus, as illustrated in this paper, the chip is capable to complete complex spatio-temporal image processing tasks within short computation time (<300 ns for linear convolutions) and using a low power budget (<1.2 W for the complete chip). The internal circuitry of the chip has been designed to operate in robust manner with >7-bits equivalent accuracy in the internal analog operations, which has been confirmed by experimental measurements. Such 7-bits accuracy is enough for most image processing applications. ACE4k has been demonstrated capable to implement up to 30 template,-either directly or through template decomposition. This means the 100% of the 3×3 linear templates reported in Roska et al. 1998, [1]. Copyright © 2002 John Wiley & Sons, Ltd. [source]


Fast proton spectroscopic imaging using steady-state free precession methods

MAGNETIC RESONANCE IN MEDICINE, Issue 3 2003
Wolfgang Dreher
Abstract Various pulse sequences for fast proton spectroscopic imaging (SI) using the steady-state free precession (SSFP) condition are proposed. The sequences use either only the FID-like signal S1, only the echo-like signal S2, or both signals in separate but adjacent acquisition windows. As in SSFP imaging, S1 and S2 are separated by spoiler gradients. RF excitation is performed by slice-selective or chemical shift-selective pulses. The signals are detected in absence of a B0 gradient. Spatial localization is achieved by phase-encoding gradients which are applied prior to and rewound after each signal acquisition. Measurements with 2D or 3D spatial resolution were performed at 4.7 T on phantoms and healthy rat brain in vivo allowing the detection of uncoupled and J-coupled spins. The main advantages of SSFP based SI are the short minimum total measurement time (Tmin) and the high signal-to-noise ratio per unit measurement time (SNRt). The methods are of particular interest at higher magnetic field strength B0, as TR can be reduced with increasing B0 leading to a reduced Tmin and an increased SNRt. Drawbacks consist of the limited spectral resolution, particularly at lower B0, and the dependence of the signal intensities on T1 and T2. Further improvements are discussed including optimized data processing and signal detection under oscillating B0 gradients leading to a further reduction in Tmin. Magn Reson Med 50:453,460, 2003. © 2003 Wiley-Liss, Inc. [source]


Rapid and sensitive magnetometer surveys of large areas using SQUIDs , the measurement system and its application to the Niederzimmern Neolithic double-ring ditch exploration

ARCHAEOLOGICAL PROSPECTION, Issue 2 2008
Volkmar Schultze
Abstract A geomagnetic field measurement system for the detection of archaeological signatures in the subsoil is presented based on the superconducting quantum interference device (SQUID). The system provides fast mapping of large areas with high magnetic field gradient resolution as well as lateral precision. The acquired data are geographically referenced and also the altitude profile is given. The properties of the system were tested intensively at the large Neolithic double-ring ditch enclosure of Niederzimmern near Weimar, Germany. Differences of the signal acquisition compared with caesium magnetometers are discussed. In the Niederzimmern double-ring ditch enclosure, with an area of 27,ha, archaeological patterns were found only near the gates. These SQUID measurements, together with accompanying excavations, provide a complex picture of the double-ring ditch enclosure, dated about 5600 years old. Copyright © 2008 John Wiley & Sons, Ltd. [source]