Home About us Contact | |||
Sensor Probe (sensor + probe)
Selected AbstractsPeptide vector for gene delivery with high affinity for phosphatidylserineJOURNAL OF PEPTIDE SCIENCE, Issue 10 2006Shinichi Kuriyama Abstract Since phosphatidylserine (PS) is known to translocate to the external face of the plasma membrane when the cell membrane becomes disordered, we decided to focus our attention on PS as a target molecule for gene delivery. In this paper, the novel peptide Td3701 was designed, synthesized, and characterized for its physico-chemico-biological properties. Td3701 simultaneously exhibited both characters as a DNA carrier and a sensor probe for active targeting, which seemed to be triggered by structural changes in the presence of PS. This is a very unique character among nonviral vectors, and it is believed that Td3701 could be used for selective gene delivery. Copyright © 2006 European Peptide Society and John Wiley & Sons, Ltd. [source] Direction sensitive sensor probe for the evaluation of voluntary and reflex pelvic floor contractions,NEUROUROLOGY AND URODYNAMICS, Issue 3 2007Christos E. Constantinou Abstract Aims The development of a vaginal probe for the evaluation of the dynamics of pelvic floor function is described. Fundamental criteria in the design of this probe involves the incorporation of a means of assessing whether the isotonic forces closing the vagina are equally distributed or whether they are greater in some directions than others. The aim of this study is to present the design of directionally sensitive multi-sensor probe, having circumferential spatial resolution, constructed to identify the distribution of anisotropic forces acting on the vagina following voluntary and reflex pelvic floor contractions. Materials and Methods Probe system consists of four pairs of force/displacement sensors mounted on leaf springs enabling isotonic measurements of voluntary and reflex contractions. Assembly is retractable to 23 mm for insertion, and expandable to 60 mm for measurement. Simultaneous measurements were made of force and displacement with the sensors oriented in the anterior/posterior and left/right orientation of the vagina. Using this probe, measurements were carried out to identify the temporal and spatial characteristic response of the vaginal wall. Data were analyzed with respect to voluntary pelvic floor and cough-induced contractions of nine subjects having a mean age of 64 years. Results A robust probe system was developed and measurements were successfully made. Initial results show that the maximum force and displacement occurs during reflex contractions in the anterior aspect of the vagina validating the anisotropic nature of the forces acting on the vaginal wall. The data also show that both the force and displacement produced by the cough-induced has a higher magnitude than voluntary pelvic floor contraction. Conclusions A directional multi-sensor vaginal probe has been developed to evaluate the force and displacement produced during isotonic pelvic floor contractions. Analysis of the results provided new biomechanical data demonstrating the anisotropic nature of vaginal closure as a consequence of pelvic floor contractions. Neurourol. Urodynam. 26:386,391, 2007. © 2007 Wiley-Liss, Inc. [source] Assessing regional hypoxia in human renal tumours using 18F-fluoromisonidazole positron emission tomographyBJU INTERNATIONAL, Issue 4 2005Nathan Lawrentschuk OBJECTIVE To assess renal tumours for hypoxic regions using 18F-fluoromisonidazole (18F-FMISO) positron emission tomography (PET), a recognized noninvasive method for detecting hypoxia in tumours, as renal cell carcinoma (RCC) can be potentially cured with nephrectomy but recurrence develops in most patients, who then respond poorly to treatments such as chemotherapy, and hypoxia is known to confer resistance to radiotherapy and chemotherapy in many solid tumours. PATIENTS AND METHODS In all, 17 patients had 18F-FMISO PET scans before nephrectomy for presumed RCC. Specimens were examined histologically, and immunohistochemistry was used to compare the microvessel density (MVD) as an indicator of angiogenesis in the tumour and normal parenchyma, in 15 patients. Tumour oxygenation was measured invasively in three patients using a polarographic oxygen sensor probe. RESULTS Of the 15 patients with histological results, 11 had RCC and four had other tumours. Although there was a trend there was no statistically significant (P = 0.14) difference in the maximum standardized uptake value (SUVmax) when comparing the region of the kidney involved with RCC; the mean (95% confidence interval) SUVmax in the tumours was 1.3 (0.15), whilst that in the normal contralateral kidney was 1.1 (0.22). The MVD was greater in RCC, at 13.7 (3.1) mean vessels per high-power field than in normal tissue, at 6.9 (1.9). Hypoxia as measured polarographically was detected in three RCCs (median pO2 9.6 mmHg) compared to normal parenchyma at 37.6 mmHg. CONCLUSIONS Although 18F-FMISO scans showed significant uptake in other solid tumours, there was only mild 18F-FMISO uptake in the present RCCs. The invasive measurements indicated that there was hypoxia in RCC, but the median pO2 did not fall below 9.5 mmHg. Further direct studies of renal tumour oxygenation combined with therapies directed towards hypoxia may allow a better understanding of the relationship between 18F-FMISO results and the biological significance of hypoxia in RCC. [source] Wet forced-air warming blankets are ineffective at maintaining normothermiaPEDIATRIC ANESTHESIA, Issue 7 2008ERICA P. LIN MD Summary Background:, Forced-air warming systems have proven effective in preventing perioperative hypothermia. To date, reported adverse events relate primarily to overheating and thermal injuries. This study uses a simple model to show that forced-air warming blankets become ineffective if they get wet. Methods:, Temperature sensor probes were inserted into three 1-liter fluid bags. Group C bags served as the control. Groups D (dry) and W (wet) bags were placed on Bair Hugger® Model 555 (Arizant Healthcare, Inc., Eden Prairie, MN, USA) pediatric underbody blankets. The warming blanket for Group W bags was subsequently wet with irrigation fluid. Temperature was documented every 5 min. This model was repeated two times for a total of three cycles. Statistical analysis was performed using anova for repeated measures. Results:, Starting temperatures for each model were within a 0.3°C range. Group C demonstrated a steady decline in temperature. Group D maintained and slightly increased in temperature during the observation period, while Group W exhibited a decrease in temperature at a rate similar to Group C. These results were significant at P < 0.005. Conclusions:, A wet forced-air warming blanket is ineffective at maintaining normothermia. Once wet, the warming blanket resulted in cooling similar to the control group. [source] |