Home About us Contact | |||
RFA Values (rfa + value)
Selected AbstractsRFA Values of Implants Placed in Sinus Grafted and Nongrafted Sites after 6 and 12 MonthsCLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, Issue 3 2009Marco Degidi MD ABSTRACT Background: Maxillary sinus floor elevation surgery is widely used as a preimplantology method to permit implant insertion. Nevertheless, very few data are available about long-term stability of dental implants inserted in grafted sites. Purpose: The aims of the present study were to evaluate the evolution of resonance frequency analysis (RFA) values at 6 and 12 months from the implant insertion in sinus grafted sites and nongrafted sites. Materials and Methods: In 14 patients, 80 Xive implants (Dentsply Friadent GmbH, Mannheim, Germany) were inserted. Sixty-three implants were inserted in a site previously treated with a sinus lift; 17 implants were inserted in healed or postextraction sites. For each implant diameter, length, bone density, insertion torque, and percentage of implant fixed to a nongrafted bone were recorded. RFA values at implant insertion after 6 and 12 months were recorded. Results: After 6 and 12 months, grafted sites showed higher RFA values than the control sites; after 12 months, the difference was statistically significant (.007). A statistically significant positive correlation was found between resonance frequency values and bone quality after 12 months (.05). No statistically significant correlation between RFA values and all the other variables considered was found. Conclusions: Sites treated with sinus lift can offer good long-term stability. After 6 and 12 months, the geometric characteristics of the implant are no longer important to obtain high RFA values, and the bone,implant interface seems to be determinant. [source] Influence of implant taper on the primary and secondary stability of osseointegrated titanium implantsCLINICAL ORAL IMPLANTS RESEARCH, Issue 4 2004Dominic O'Sullivan Abstract Objectives: The study presented was designed to analyse the mechanical performance and the primary and secondary stability characteristics of endosseous titanium implants with 1° (EXP1) and 2° (EXP2) of taper when compared with the standard Brånemark design (Nobel Biocare AB, Gothenburg, Sweden). Materials and methods: One pair of 10 mm EXP1 and control implants were placed in the femoral condyles of six rabbits. Paired 6 mm EXP1 and control implants and 6 mm EXP2 and control implants were placed in the tibial metaphysis. The control implants used were 4 mm diameter standard Brånemark implants, the same length as the test implants. At placement, insertion torque (IT) and resonance frequency analysis (RFA) measurements were performed. Six weeks postoperatively when the animals were killed, RFA and removal torque (RT) measurements were made. Results: At placement, significantly higher IT was needed to insert the EXP implants compared with the controls. RFA values were significantly higher for EXP1 implants placed in the tibia but not in the femur. In pooling data from the femur and tibia there was a significant difference. The EXP2 implants failed to insert fully and demonstrated a lower RFA value than may have been expected due to the exposed threads, although this difference was not statistically significant. Conclusions: The results from the present study showed that 1° of taper results in a better primary stability compared with the standard Brånemark design. There was no evidence that the tapered design caused negative bone tissue reactions. All the implants gained in stability during the healing period. Résumé L'étude présente a été effectuée pour analyser la performance mécanique et les caractéristiques de stabilité primaire et secondaire d'implants endoosseux en titane avec un taper (fuselé) 1° (EXP1) et 2 (EXP 2) comparés au modèle ad modum Branemark® standard. Une paire d'implants contrôles et un EXP1 de 10 mm ont été placés dans les condyles fémoraux de six lapins. Des paires d'implants contrôles et EXP1 de 6 mm et des implants contrôles et EXP2 de 6 mm ont été placés dans les métaphyses tibiales. Les implants contrôles utilisés avaient un diamètre standard de 4 mm, la même longueur que les implants tests. Lors du placement, des mesures de force d'insertion (IT) et d'analyse de fréquence de résonnance (RFA) ont été effectuées. Six semaines après l'opération lorsque les animaux ont été euthanasiés, les mesures RFA et les forces d'enlèvement (RT) ont été relevées. Lors du placement un IT significativement plus important a été nécessaire pour insérer les implants EXP1 comparé au contrôle. Les valeurs RFA étaient significativement plus importantes pour les implants EXP1 placés dans le tibia mais pas dans le fémur. En rassemblant les données du fémur et du tibia il y avait une différence significative. Les implants EXP2 ne parvenaient pas àêtre insérés à fond et ont montré une valeur RFA inférieure qui n'était pas inattendue vu les filetages exposés bien que ces différences n'étaient pas statistiquement significatives. Les résultats de l'étude présente ont montré que le taper 1 résultait en une stabilité primaire supérieure comparé au modèle ad modum Branemark® standard. Il n'y avait aucun signe que ce nouveau modèle causait des réactions tissulaires osseuses négatives. Tous les implants ont gagné en stabilité durant leur période de guérison. Zusammenfassung Ziele: Die hier vorgestellte Studie hatte zum Ziel, das mechanische Verhalten und die Charakteristika von Primär- und Sekundärstabilität bei enossalen Implantaten mit einer Gewindeneigung von 1° (EXP1) und von 2° (EXP2) zu untersuchen. Man verglich die Daten mit dem Standarddesign von Brånemark (Nobel Biocare AB, Gothenburg, Schweden). Material und Methode: Man implantierte ein Päärchen von 10mm-Implantaten (EXP1 und Kontrollimplantat) in die Femurkondylen von 6 Kaninchen. Zwei weitere Päärchen von 6mm-Implantaten (EXP1 und Kontrollimplantat, sowie EXP2 und Kontrollimplantat) implantierte man in die Metaphyse der Tibia. Bei den Kontrollimplantaten handelte es sich um Standardtypen von Brånemark mit einem Durchmesser von 4 Millimetern und derselben Länge wie die Testimplantate. Bei der Implantation mass man die Kraft, die es zu Eindrehen der Implantate brauchte (IT) und führte Messungen mit der Resonanzfrequenzanalyse (RFA) durch. Sechs Wochen nach der Operation wurden die Tiere geopfert, die RFA erneut durchgeführt und anschliessend der Ausdrehwiderstand (RT) bestimmt. Resultate: Bei der Implantation brauchte es signifikant grössere IT um die EXP-Implantate einzusetzen, als bei den Kontrollimplantaten. Die RFA-Werte waren bei den EXP1-Implantaten, die in die Tibia geschraubt worden waren, signifikant höher. Dies gilt aber nicht für die in den Femur geschraubten Implantate. Wurden die Daten vom Femur mit denen der Tibia verglichen, so erkannte man signifikante Unterschiede. Die EXP2-Implantate konnten nicht vollständig inseriert werden und zeigten auch tiefere RFA-Werte, als man den freiliegenden Schraubenwindungen entsprechend erwarten könnte. Diese Unterschiede waren aber nicht statistisch signifikant. Zusammenfassung: Die Resultate dieser Studie zeigten, das Schraubenwindungen mit 1° Steigung verglichen mit dem Standarddesign von Brånemark eine bessere Primärstabilität erzielten. Man fand andererseits keine Beweise, dass sich dieses neue Design der Schraubenwindungen negativ auf die Reaktion des Knochengewebes auswirkt. Alle Implantate gewannen während in der Heilphase an Stabilität dazu. Resumen Objetivos: El estudio presentado se diseñó para analizar el rendimiento mecánico y las características de estabilidad primaria y secundaria de implantes endoóseos de titanio con 1o (EXP1) y 2o (EXP 2) de autoroscado al compararlos con el diseño estándar de Brånemark (Nobel Biocare AB, Gothenburg, Suecia). Material y Métodos: Se colocó una pareja de implantes de 10 mm EXP1 y de control en los cóndilos femorales de 6 conejos. Se colocaron pareja de implantes de 6 mm EXP1 y de control y de 6 mm EXP2 y de control en la metáfisis tibial. Los implantes de control utilizados fueron Brånemark estándar de 4 mm de diámetro. A la colocación, se llevaron a cabo mediciones del torque de inserción (IT) y del análisis de la frecuencia de resonancia (RFA). Los animales se sacrificaron a las seis semanas de la operación, y se tomaron medidas del torque de remoción (RT). Resultados: Al colocarse, se necesitó un IT significativamente mas alto para insertar los implantes EXP en comparación con los de control. Los valores RFA fueron significativamente mas altos para implantes EXP1 colocados en la tibia pero no en el fémur. Confrontando los datos del fémur y de la tibia apareció una diferencia significativa. Los implantes EXP2 fracasaron en insertarse completamente y demostraron un menor valor de RFA del que se podía esperar debido a la exposición de las roscas, aunque esta diferencia no fue estadísticamente significativa. Conclusiones: Los resultados del presente estudio mostraron que 1o de autoroscado resultan en una mejor estabilidad primaria comparada con el diseño estándar de Brånemark. No hubo evidencia de que el diseño de autoroscado causara reacciones negativas en el tejido óseo. Todos los implantes ganaron estabilidad durante el periodo de cicatrización. [source] Increased bone formation around coated implantsJOURNAL OF CLINICAL PERIODONTOLOGY, Issue 8 2009Bernd Stadlinger Abstract Aim: We hypothesized that coating threaded, sandblasted acid-etched titanium implants with collagen and chondroitin sulphate (CS) increases bone formation and implant stability, compared with uncoated controls. Materials and Methods: Three different implant surface conditions were applied: (1) sandblasted acid-etched (control), (2) collagen/chondroitin sulphate (low-dose , CS1), (3) collagen/chondroitin sulphate (high-dose , CS2). Sixty 9.5 mm experimental implants were placed in the mandible of 20 minipigs. Bone,implant contact (BIC) and relative peri-implant bone-volume density (rBVD , relation to bone-volume density of the host bone) were assessed after 1 and 2 months of submerged healing. Implant stability was measured by resonance frequency analysis (RFA). Results: After 1 month, coated implants had significantly more BIC compared with controls (CS1: 68%, p<0.0001, CS2: 63%, p=0.009, control: 52%). The rBVD was lower for all surface conditions, compared with the hostbone. After 2 months, BIC increased for all surfaces. No significant differences were measured (CS1: 71%, p=0.016, CS2: 68%, p=0.67, control: 63%). The rBVD was increased for coated implants. RFA values were 71,77 at implantation, 67,73 after 1 month and 74,75 after 2 months. Differences in rBVD and RFA were not statistically significant. Conclusions: Data analysis suggests that collagen/CS has a positive influence on bone formation after 1 month of endosseous healing. [source] RFA Values of Implants Placed in Sinus Grafted and Nongrafted Sites after 6 and 12 MonthsCLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, Issue 3 2009Marco Degidi MD ABSTRACT Background: Maxillary sinus floor elevation surgery is widely used as a preimplantology method to permit implant insertion. Nevertheless, very few data are available about long-term stability of dental implants inserted in grafted sites. Purpose: The aims of the present study were to evaluate the evolution of resonance frequency analysis (RFA) values at 6 and 12 months from the implant insertion in sinus grafted sites and nongrafted sites. Materials and Methods: In 14 patients, 80 Xive implants (Dentsply Friadent GmbH, Mannheim, Germany) were inserted. Sixty-three implants were inserted in a site previously treated with a sinus lift; 17 implants were inserted in healed or postextraction sites. For each implant diameter, length, bone density, insertion torque, and percentage of implant fixed to a nongrafted bone were recorded. RFA values at implant insertion after 6 and 12 months were recorded. Results: After 6 and 12 months, grafted sites showed higher RFA values than the control sites; after 12 months, the difference was statistically significant (.007). A statistically significant positive correlation was found between resonance frequency values and bone quality after 12 months (.05). No statistically significant correlation between RFA values and all the other variables considered was found. Conclusions: Sites treated with sinus lift can offer good long-term stability. After 6 and 12 months, the geometric characteristics of the implant are no longer important to obtain high RFA values, and the bone,implant interface seems to be determinant. [source] Implant stability during osseointegration in irradiated and non-irradiated minipig alveolar bone: an experimental studyCLINICAL ORAL IMPLANTS RESEARCH, Issue 2 2008Henk W. D. Verdonck Abstract: Objectives: Primary implant stability is related to local bone density. After insertion of an implant, implant stability is subject to changes due to bone remodeling. In patients who have undergone radiotherapy in the head and neck region, implant stability is impaired because irradiation reduces bone vitality. The current study was designed to monitor and test implant stability immediately after implant placement and during osseointegration in irradiated and non-irradiated minipig alveolar bone. Materials and methods: All maxillary and mandibular premolars and molars of six adult Göttingen minipigs were extracted. The maxilla and mandible of three minipigs received three irradiation exposures at a total dose of 24 Gy. After irradiation, five initial implant holes were drilled in the residual alveolar ridge of each edentulous site. In order to assess bone vascularity, laser Doppler flowmetry recordings were carried out in the initial holes. A total of 120 implants were placed in the six minipigs. Subsequently, and at 8, 16, and 24 weeks after implant placement, implant stability was recorded by resonance frequency analysis (RFA). RFA values were expressed as an implant stability quotient (ISQ). Results: ISQ values recorded immediately after implant placement showed no differences between irradiated and non-irradiated minipigs. Repeated measurements at the four recording moments showed a decrease of ISQ values in all minipigs, being more pronounced in irradiated bone, when compared with non-irradiated bone. The results at the third and fourth recording moments showed a stabilization or even a slight increase of ISQ values. Conclusions: The results document the negative effect of irradiation on bone vascularity and hence on implant stability. [source] Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdenturesCLINICAL ORAL IMPLANTS RESEARCH, Issue 6 2005vanç Akça Abstract Purpose: To evaluate ex vivo bone tissue strains around maxillary implants supporting immediately loaded bar-retained overdentures. Material and methods: Ninety degree two-element rosette strain gauges were bonded on the labial bone of four ITI® dental implants placed in the maxillary anterior region of four completely edentulous maxilla of fresh human cadavers. The installation torque value (ITV) of each implant was measured by a custom-made torque wrench and resonance frequency analyses (RFAs) were undertaken. A bar-retained overdenture was fabricated for each cadaver, and two miniature load cells were integrated in the first molar region of the overdentures for controlled loading experiments. Strain measurements were performed at a sample rate of 10 kHz and under a maximum load of 100 N, simultaneously monitored from a computer connected to a data acquisition system. Finally, removal torque values (RTVs) of the implants were measured. Results: RFA values did not mirror ITVs, while RTVs of implants were slightly lower than the ITVs. Any correlation could not be obtained between RFA values and ITVs or RTVs. Maximum strains around loaded implants ranged between ,100 and ,550 ,, under 25,100 N. The axial and lateral strain values of posterior implants of both sides were higher than those of anterior implants under all loads (P<0.05). Conclusion: Because occlusal forces in humans tend to decrease because of age-related factors, maximum strains around immediately loaded implants supporting maxillary overdentures fall within physiologic levels. Résumé Le but de cette étude a été d'évaluer les tensions du tissu osseux ex vivo autour d'implants maxillaires portant des prothèses amovibles retenues sur une barre placée immédiatement après l'insertion des implants. Deux jauges de force en rosette à 90° ont été attachées au côté lingual de l'os de quatre implants dentaires ITI® placés dans la région antérieure du maxillaire de quatre cadavres humains frais aux maxillaires édentées. La valeur du couple de torsion lors de l'installation (ITV) de chaque implant a été mesurée par un couple fabriqué et des analyses de fréquence de résonnance (RFA) ont été faites. Une prothèse retenue par une barre a été fabriquée pour chaque cadavre et deux cellules de charge miniatures ont été intégrées dans la région de la première molaire de ces prothèses pour les expériences de charge contrôlées. Les mesures de force ont été effectuées à un taux d'échantillonnage de 10 kHz et sous une charge maximale de 100 N, suivies simultanément par un ordinateur connectéà un système d'acquisition de données. Finalement les valeurs des couples de torsion à l'enlèvement (RTV) des implants ont été mesurées. Les valeurs RFA n'étaient pas en ligne avec les ITV tandis que les RTV des implants étaient légèrement inférieurs aux ITV. Aucune corrélation n'a pûêtre établie entre les valeurs RFA et ITV ou RTV. Les forces maximales autour des implants chargés s'étalaient de ,100 ,e à,550 ,e sous 25 N à 100 N. Les valeurs des forces axiales et latérales des implants postérieurs des deux côtés étaient supérieures à celles des implants antérieurs sous toutes les charges (P<0.05). Zusammenfassung Ziel: Es war das Ziel dieser Arbeit, an bis vor kurzem vitalen Knochengewebe Spannungen um Oberkieferimplantate zu untersuchen, welche sofortbelastete und stegverankerte Hybridprothesen tragen. Material und Methoden: Auf den labialen Knochen von vier ITI-Implantaten in der vorderen Region des zahnlosen Oberkiefers von vier frisch verstorbenen Menschen klebte man Dehnmessinstrumente an. Man mass den Wert der Eindrehkraft (ITV) jedes einzelnen Implantates mit einem handelsblichen Drehmomentschlssel und fhrte eine Resonanzfrequenzanalyse (RFA) durch. Man stellte fr jede Leiche eine stegverankerte Hybridprothese her und man baute in der Region der ersten Molaren zwei kleine Messgerte ein, die kontrollierte Belastungsexperimente erlaubten. Dehnmessungen fhrte man mit einer Frequenz von 10 kHz und einer maximalen Belastung von 100 N durch, simultan aufgezeichnet von einem mit dem Messsystem verbundenen Komputer. Schliesslich mass man auch die Krfte, die es brauchte um die Implantate wieder auszudrehen (RTV). Resultate: Die RFA wiederspiegelte die ITV-Werte nicht, whrenddem die RTV-Werte der Implantate geringfgig tiefer waren als die ITV-Werte. Man konnte weder zwischen der RFA, den ITV-Werten oder den RTV-Werten eine Korrelation herstellen. Die maximalen Dehnungen um die Implantate erreichte Werte zwischen ,100 E und ,550 E bei einer Belastung zwischen 25 N und 100 N. Die axialen und lateralen Dehnkrfte bei posterioren Implantaten waren unter smtlichen getesteten Belastungen beidseits grsser als diejenigen der anterioren Implantate (P<0.05). Resumen Propósito: Evaluar las tensiones del tejido óseo ex vivo alrededor de implantes maxilares soportando sobredentaduras retenidas por barras con carga inmediata. Material y Métodos: Se pegaron dos indicadores de tensión de roseta de dos elementos de 90° en el hueso labial de cuatro implantes dentales ITI® colocados en la región maxilar anterior de cuatro maxilares completamente edéntulos de cadáveres humanos frescos. Se midió el valor del torque de instalación (ITV) de cada implante por medio de una chicharra de torque hecha a medida y se llevó a cabo análisis de frecuencia de resonancia (RFA). Se fabricó una sobredentadura retenida por barras para cada cadáver y se integraron dos células miniatura de carga en la región del primer molar de las sobredentaduras para los experimentos de carga controlada. Se llevaron a cabo mediciones de la tensión a un índice de muestra de 10 kHz y bajo una carga máxima de 100 N, simultáneamente monitorizada desde un ordenador conectado a sistema de adquisición de datos. Finalmente, se midieron los valores del torque de remoción (RTV) de los implantes. Resultados: Los valores de RFA no se reflejaron en los ITVs, mientras que los RTVs de los implantes fueron ligeramente más bajos que los ITVs. No se pudieron obtener correlaciones entre los valores de RFA y los ITVs o RTVE. Las tensiones máximas alrededor de los implantes cargados variaron entre ,100 ,, y ,550 ,, bajo 25 N a 100 N. Los valores de las tensiones axiales y laterales de los implantes posteriores de ambos lados fueron mayores que aquellos implantes anteriores bajo todas las cargas (P<0.05). [source] Influence of implant taper on the primary and secondary stability of osseointegrated titanium implantsCLINICAL ORAL IMPLANTS RESEARCH, Issue 4 2004Dominic O'Sullivan Abstract Objectives: The study presented was designed to analyse the mechanical performance and the primary and secondary stability characteristics of endosseous titanium implants with 1° (EXP1) and 2° (EXP2) of taper when compared with the standard Brånemark design (Nobel Biocare AB, Gothenburg, Sweden). Materials and methods: One pair of 10 mm EXP1 and control implants were placed in the femoral condyles of six rabbits. Paired 6 mm EXP1 and control implants and 6 mm EXP2 and control implants were placed in the tibial metaphysis. The control implants used were 4 mm diameter standard Brånemark implants, the same length as the test implants. At placement, insertion torque (IT) and resonance frequency analysis (RFA) measurements were performed. Six weeks postoperatively when the animals were killed, RFA and removal torque (RT) measurements were made. Results: At placement, significantly higher IT was needed to insert the EXP implants compared with the controls. RFA values were significantly higher for EXP1 implants placed in the tibia but not in the femur. In pooling data from the femur and tibia there was a significant difference. The EXP2 implants failed to insert fully and demonstrated a lower RFA value than may have been expected due to the exposed threads, although this difference was not statistically significant. Conclusions: The results from the present study showed that 1° of taper results in a better primary stability compared with the standard Brånemark design. There was no evidence that the tapered design caused negative bone tissue reactions. All the implants gained in stability during the healing period. Résumé L'étude présente a été effectuée pour analyser la performance mécanique et les caractéristiques de stabilité primaire et secondaire d'implants endoosseux en titane avec un taper (fuselé) 1° (EXP1) et 2 (EXP 2) comparés au modèle ad modum Branemark® standard. Une paire d'implants contrôles et un EXP1 de 10 mm ont été placés dans les condyles fémoraux de six lapins. Des paires d'implants contrôles et EXP1 de 6 mm et des implants contrôles et EXP2 de 6 mm ont été placés dans les métaphyses tibiales. Les implants contrôles utilisés avaient un diamètre standard de 4 mm, la même longueur que les implants tests. Lors du placement, des mesures de force d'insertion (IT) et d'analyse de fréquence de résonnance (RFA) ont été effectuées. Six semaines après l'opération lorsque les animaux ont été euthanasiés, les mesures RFA et les forces d'enlèvement (RT) ont été relevées. Lors du placement un IT significativement plus important a été nécessaire pour insérer les implants EXP1 comparé au contrôle. Les valeurs RFA étaient significativement plus importantes pour les implants EXP1 placés dans le tibia mais pas dans le fémur. En rassemblant les données du fémur et du tibia il y avait une différence significative. Les implants EXP2 ne parvenaient pas àêtre insérés à fond et ont montré une valeur RFA inférieure qui n'était pas inattendue vu les filetages exposés bien que ces différences n'étaient pas statistiquement significatives. Les résultats de l'étude présente ont montré que le taper 1 résultait en une stabilité primaire supérieure comparé au modèle ad modum Branemark® standard. Il n'y avait aucun signe que ce nouveau modèle causait des réactions tissulaires osseuses négatives. Tous les implants ont gagné en stabilité durant leur période de guérison. Zusammenfassung Ziele: Die hier vorgestellte Studie hatte zum Ziel, das mechanische Verhalten und die Charakteristika von Primär- und Sekundärstabilität bei enossalen Implantaten mit einer Gewindeneigung von 1° (EXP1) und von 2° (EXP2) zu untersuchen. Man verglich die Daten mit dem Standarddesign von Brånemark (Nobel Biocare AB, Gothenburg, Schweden). Material und Methode: Man implantierte ein Päärchen von 10mm-Implantaten (EXP1 und Kontrollimplantat) in die Femurkondylen von 6 Kaninchen. Zwei weitere Päärchen von 6mm-Implantaten (EXP1 und Kontrollimplantat, sowie EXP2 und Kontrollimplantat) implantierte man in die Metaphyse der Tibia. Bei den Kontrollimplantaten handelte es sich um Standardtypen von Brånemark mit einem Durchmesser von 4 Millimetern und derselben Länge wie die Testimplantate. Bei der Implantation mass man die Kraft, die es zu Eindrehen der Implantate brauchte (IT) und führte Messungen mit der Resonanzfrequenzanalyse (RFA) durch. Sechs Wochen nach der Operation wurden die Tiere geopfert, die RFA erneut durchgeführt und anschliessend der Ausdrehwiderstand (RT) bestimmt. Resultate: Bei der Implantation brauchte es signifikant grössere IT um die EXP-Implantate einzusetzen, als bei den Kontrollimplantaten. Die RFA-Werte waren bei den EXP1-Implantaten, die in die Tibia geschraubt worden waren, signifikant höher. Dies gilt aber nicht für die in den Femur geschraubten Implantate. Wurden die Daten vom Femur mit denen der Tibia verglichen, so erkannte man signifikante Unterschiede. Die EXP2-Implantate konnten nicht vollständig inseriert werden und zeigten auch tiefere RFA-Werte, als man den freiliegenden Schraubenwindungen entsprechend erwarten könnte. Diese Unterschiede waren aber nicht statistisch signifikant. Zusammenfassung: Die Resultate dieser Studie zeigten, das Schraubenwindungen mit 1° Steigung verglichen mit dem Standarddesign von Brånemark eine bessere Primärstabilität erzielten. Man fand andererseits keine Beweise, dass sich dieses neue Design der Schraubenwindungen negativ auf die Reaktion des Knochengewebes auswirkt. Alle Implantate gewannen während in der Heilphase an Stabilität dazu. Resumen Objetivos: El estudio presentado se diseñó para analizar el rendimiento mecánico y las características de estabilidad primaria y secundaria de implantes endoóseos de titanio con 1o (EXP1) y 2o (EXP 2) de autoroscado al compararlos con el diseño estándar de Brånemark (Nobel Biocare AB, Gothenburg, Suecia). Material y Métodos: Se colocó una pareja de implantes de 10 mm EXP1 y de control en los cóndilos femorales de 6 conejos. Se colocaron pareja de implantes de 6 mm EXP1 y de control y de 6 mm EXP2 y de control en la metáfisis tibial. Los implantes de control utilizados fueron Brånemark estándar de 4 mm de diámetro. A la colocación, se llevaron a cabo mediciones del torque de inserción (IT) y del análisis de la frecuencia de resonancia (RFA). Los animales se sacrificaron a las seis semanas de la operación, y se tomaron medidas del torque de remoción (RT). Resultados: Al colocarse, se necesitó un IT significativamente mas alto para insertar los implantes EXP en comparación con los de control. Los valores RFA fueron significativamente mas altos para implantes EXP1 colocados en la tibia pero no en el fémur. Confrontando los datos del fémur y de la tibia apareció una diferencia significativa. Los implantes EXP2 fracasaron en insertarse completamente y demostraron un menor valor de RFA del que se podía esperar debido a la exposición de las roscas, aunque esta diferencia no fue estadísticamente significativa. Conclusiones: Los resultados del presente estudio mostraron que 1o de autoroscado resultan en una mejor estabilidad primaria comparada con el diseño estándar de Brånemark. No hubo evidencia de que el diseño de autoroscado causara reacciones negativas en el tejido óseo. Todos los implantes ganaron estabilidad durante el periodo de cicatrización. [source] |