Quantitative Procedure (quantitative + procedure)

Distribution by Scientific Domains


Selected Abstracts


FT-IR measurements of petroleum fluid inclusions: methane, n -alkanes and carbon dioxide quantitative analysis

GEOFLUIDS (ELECTRONIC), Issue 1 2001
J. Pironon
Abstract A recent advancement in petroleum geochemistry is to model fossil oil composition using microthermometric and volumetric data acquired from individual fluid inclusion analysis. Fourier transform infrared (FT-IR) microspectroscopy can record compositional information related to gas (CH4 and CO2) and alkane contents of petroleum inclusions. In this study, a quantitative procedure for FT-IR microspectrometry has been developed to obtain, from individual fluid inclusions, mol percentage concentrations of methane, alkanes and carbon dioxide as constraints to thermodynamic modelling. A petroleum inclusion in a sample from the Québec City Promontory nappe area was used as standard to record a reference spectrum of methane. The analytical procedure is based on the measurement of CH4/alkane and CH4/CO2 band area ratios. CH4/alkane infrared band area ratio is obtained after spectral subtraction of the reference methane spectrum. This area ratio, affected by absolute absorption intensities of methane, methyl and methylene, provides a molar CH4/alkane ratio. Methyl/methylene ratio (CH2/CH3) ratio is obtained following procedures established in previous work. CO2/CH4 concentration ratio is estimated from relative absolute absorption intensities. Application to natural inclusions from different environments shows good correlation between FT-IR quantification and PIT (petroleum inclusion thermodynamic) modelling. [source]


Use of optical coherence tomography for assessment of dental caries: quantitative procedure

JOURNAL OF ORAL REHABILITATION, Issue 12 2001
B. T. Amaechi
A method for quantitative assessment of dental caries using optical coherence tomography (OCT) was demonstrated. Development of caries lesions in 15 bovine teeth, by demineralization in acidic buffer solution, was quantitatively assessed daily for 3 days, using OCT. An OCT system which can collect A-scans (depth versus reflectivity curve), B-scans (longitudinal images) and C-scans (transverse images at constant depth) was used. While the B- and C-scans qualitatively described the lesion detected, the A-scan which showed the depth (mm) resolved reflectivity (dB) of the tooth tissue was used for the quantitative analysis. After a simple normalization procedure to determine the actual depth the light travelled into the tooth tissue, the area (R) under the A-scan was quantified as a measure of the degree of reflectivity of the tissue. The result showed that R (dB mm) decreased with increasing demineralization time. The percentage reflectivity loss (R%) in demineralized tissue, which related to the amount of mineral loss, was also calculated, and it was observed that R% increased with increasing demineralization time. It was concluded that with the above procedure, OCT could quantitatively monitor the mineral changes in a caries lesion on a longitudinal basis. [source]


Quantitative analysis of messenger RNA abundance for ribosomal protein L-15, cyclophilin-A, phosphoglycerokinase, ,-glucuronidase, glyceraldehyde 3-phosphate dehydrogenase, ,-actin, and histone H2A during bovine oocyte maturation and early embryogenesis in vitro

MOLECULAR REPRODUCTION & DEVELOPMENT, Issue 3 2006
AnilKumar Bettegowda
Abstract Real-time reverse transcription PCR has greatly improved the ease and sensitivity of quantitative gene expression studies. However, measurement of gene expression generally requires selection of a valid reference (housekeeping gene) for data normalization to compensate for inherent variations. Given the dynamic nature of early embryonic development, application of this technology to studies of oocyte and early embryonic development is further complicated due to limited amounts of starting material and a paucity of information on constitutively expressed genes for data normalization. We have validated quantitative procedures for real-time reverse transcription polymerase chain reaction (RT-PCR) analysis of mRNA abundance during bovine meiotic maturation and early embryogenesis and utilized this technology to determine temporal changes in mRNA abundance for ribosomal protein L-15, cyclophilin-A, phosphoglycerokinase, ,-glucuronidase, glyceraldehyde-3-phosphate dehydrogenase, ,-actin, and histone H2A. Quantification of amounts of specific exogenous RNAs added to samples revealed acceptable rates of RNA recovery and efficiency of reverse transcription with minimal variation. Progression of bovine oocytes to metaphase II resulted in reduced abundance of polyadenylated, but not total transcripts for majority of above genes; however phosphoglycerokinase exhibited a significant decline in both RNA populations. Abundance of mRNAs for above genes in early embryos generally remained low until the blastocyst stage, but abundance of ribosomal protein L-15 mRNA was increased at the morula stage and histone H2A mRNA showed dynamic changes prior to embryonic genome activation. Results demonstrate a valid approach for quantitative analysis of mRNA abundance in oocytes and embryos, but do not support constitutive expression of above genes during early embryonic development. Mol. Reprod. Dev. © 2005 Wiley-Liss, Inc. [source]


A comparison of measures of disproportionality for signal detection in spontaneous reporting systems for adverse drug reactions

PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, Issue 1 2002
Eugéne P. van Puijenbroek
Abstract Purpose A continuous systematic review of all combinations of drugs and suspected adverse reactions (ADRs) reported to a spontaneous reporting system, is necessary to optimize signal detection. To focus attention of human reviewers, quantitative procedures can be used to sift data in different ways. In various centres, different measures are used to quantify the extent to which an ADR is reported disproportionally to a certain drug compared to the generality of the database. The objective of this study is to examine the level of concordance of the various estimates to the measure used by the WHO Collaborating Centre for International ADR monitoring, the information component (IC), when applied to the dataset of the Netherlands Pharmacovigilance Foundation Lareb. Methods The Reporting Odds Ratio,1.96 standard errors (SE), proportional reporting ratio,1.96 SE, Yule's Q,1.96,SE, the Poisson probability and Chi-square test of all 17,330 combinations were compared with the IC minus 2 standard deviations. Additionally, the concordance of the various tests, in respect to the number of reports per combination, was examined. Results In general, sensitivity was high in respect to the reference measure when a combination of point- and precision estimate was used. The concordance increased dramatically when the number of reports per combination increased. Conclusion This study shows that the different measures used are broadly comparable when four or more cases per combination have been collected. Copyright © 2001 John Wiley & Sons, Ltd. [source]