Pulse Oximetry (pulse + oximetry)
Selected AbstractsThe Significance of Pulse Oximetry in the Diagnosis of Pacemaker Failure to OutputANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 3 2010Athanasios Michailidis M.D. In a routine monitor electrocardiogram few hours after implantation of a dual-chamber pacemaker, there was a suspicion of ventricular oversensing leading to failure to output. Pulse oximeter plethysmographic wave signal virtually excluded this suspicion. This case report demonstrates the clinical utility of initial pulse oximeter wave analysis in excluding pacemaker failure to output. Ann Noninvasive Electrocardiol 2010;15(3):293,295 [source] Trends in hospital-based management of acute asthma from a teaching hospital in South AsiaINTERNATIONAL JOURNAL OF CLINICAL PRACTICE, Issue 8 2005S. F. Hussain Summary The aim of this study is to evaluate the hospital-based management of acute asthma in south Asia and to compare practices over a 10-year period. Adult patients (n = 102) admitted at a teaching hospital with acute asthma were studied. Documentation of precipitating factors, family history and physical signs were inadequate in more than half of patients. Pulse oximetry was documented in 95 (93%) patients, but peak flow monitoring was performed only in 50 (49%) patients. Ten-year trend showed deterioration in history and physical examination skills, under use of peak flow readings, and poor pre-discharge instructions. Some aspects of improved care included frequent use of pulse oximeter, preference of inhaled over systemic bronchodilators and increased use of systemic steroids. Significant deficiencies were identified in hospital-based management of acute asthma. Most aspects of asthma care continued to fall short of asthma guidelines. [source] Deceptive simplicity: Systemic oxygen delivery and pulse oximetryJOURNAL OF PAEDIATRICS AND CHILD HEALTH, Issue 7-8 2007Clare L Collins Abstract: Pulse oximetry is often perceived to be a measure of the adequacy of oxygen delivery. It is, however, only a measure of oxygen bound to haemoglobin. Systemic oxygen delivery is principally determined by cardiac output, haemoglobin concentration and haemoglobin saturation. Changes to both cardiac output and haemoglobin concentration will significantly alter oxygen delivery without changing oxygen saturation. This article will describe the components of systemic oxygen delivery and the physiologic limitation of pulse oximetry and caution against over-interpretation of oximetry in the care of newborns. [source] Utility of pulse oximetry in the detection of arterial hypoxemia in liver transplant candidatesLIVER TRANSPLANTATION, Issue 4 2002Gary A. Abrams MD Assistant Professor of Medicine Hepatopulmonary syndrome, arterial hypoxemia caused by intrapulmonary vasodilatation, occurs in approximately 10% of patients with cirrhosis. The severity of hypoxemia affects liver transplant candidacy and is associated with increased morbidity and mortality posttransplantation. Screening guidelines for detecting the presence of arterial hypoxemia do not exist. The aim of this study is to investigate the accuracy and utility of pulse oximetry in the detection of hypoxemia (PaO2 < 70 mm Hg) in patients with cirrhosis. Two hundred prospective liver transplant candidates were compared with 94 controls. Arterial oxyhemoglobin saturation was obtained by pulse oximetry (SpO2) and compared with simultaneous arterial blood gas (ABG) oxyhemoglobin values (SaO2; bias = the difference). PaO2, carboxyhemoglobin, methemoglobin, and routine clinical and biochemical parameters were investigated to account for the bias. SpO2 overestimated SaO2 in 98% of patients with cirrhosis (mean bias, 3.37%; range, ,1% to 10%). Forty-four percent of patients with cirrhosis and controls had a bias of 4% or greater. No clinical or biochemical parameters of cirrhosis accounted for the overestimation of pulse oximetry. Twenty-five subjects with cirrhosis were hypoxemic, and an SpO2 of 97% or less showed a sensitivity of 96% and a positive likelihood ratio of 3.9 for detecting hypoxemia. An SpO2 of 94% or less detected all subjects with an arterial PaO2 less than 60 mm Hg. Pulse oximetry significantly overestimates arterial oxygenation, and the inaccuracy is not influenced by liver disease. Nevertheless, pulse oximetry can be a useful screening tool to detect arterial hypoxemia in patients with cirrhosis, but a higher threshold for obtaining an ABG must be used. [source] Global oximetry: an international anaesthesia quality improvement projectANAESTHESIA, Issue 10 2009I. A. Walker Summary Pulse oximetry is mandatory during anaesthesia in many countries, a standard endorsed by the World Health Organization ,Safe Surgery Saves Lives' initiative. The Association of Anaesthetists of Great Britain and Ireland, the World Federation of Societies of Anaesthesiologists and GE Healthcare collaborated in a quality improvement project over a 15-month period to investigate pulse oximetry in four pilot sites in Uganda, Vietnam, India and the Philippines, using 84 donated pulse oximeters. A substantial gap in oximeter provision was demonstrated at the start of the project. Formal training was essential for oximeter-naïve practitioners. After introduction of oximeters, logbook data were collected from over 8000 anaesthetics, and responses to desaturation were judged appropriate. Anaesthesia providers believed pulse oximeters were essential for patient safety and defined characteristics of the ideal oximeter for their setting. Robust systems for supply and maintenance of low-cost oximeters are required for sustained uptake of pulse oximetry in low- and middle-income countries. [source] Pulse oximetry from a haemofiltration lineANAESTHESIA, Issue 8 2001N. Sharma First page of article [source] Screening for duct-dependent congenital heart disease with pulse oximetry: A critical evaluation of strategies to maximize sensitivityACTA PAEDIATRICA, Issue 11 2005ANNE DE-WAHL GRANELLI Abstract Aim: To evaluate the feasibility of detecting duct-dependent congenital heart disease before hospital discharge by using pulse oximetry. Design: Case-control study. Setting: A supra-regional referral centre for paediatric cardiac surgery in Sweden. Patients: 200 normal term newborns with echocardiographically normal hearts (median age 1.0 d) and 66 infants with critical congenital heart disease (CCHD; median age 3 d). Methods: Pulse oximetry was performed in the right hand and one foot using a new-generation pulse oximeter (NGoxi) and a conventional-technology oximeter (CToxi). Results: With the NGoxi, normal newborns showed a median postductal saturation of 99% (range 94,100%); intra-observer variability showed a mean difference of 0% (SD 1.3%), and inter-observer variability was 0% (SD 1.5%). The CToxi recorded a significantly greater proportion of postductal values below 95% (41% vs 1%) in the normal newborns compared with NGoxi (p < 0.0001). The CCHD group showed a median postductal saturation of 90% (45,99%) with the NGoxi. Analysis of distributions suggested a screening cut-off of < 95%; however, this still gave 7/66 false-negative patients, all with aortic arch obstruction. Best sensitivity was obtained by adding one further criterion: saturation of < 95% in both hand and foot or a difference of > ± 3% between hand and foot. These combined criteria gave a sensitivity of 98.5%, specificity of 96.0%, positive predictive value of 89.0% and negative predictive value of 99.5%. Conclusion: Systematic screening for CCHD with high accuracy requires a new-generation oximeter, and comparison of saturation values from the right hand and one foot substantially improves the detection of CCHD. [source] Intravenous lidocaine for status epilepticus during childhoodDEVELOPMENTAL MEDICINE & CHILD NEUROLOGY, Issue 3 2006Shin-ichiro Hamano MD; The clinical efficacy of lidocaine for convulsive status epilepticus in 53 convulsive episodes was examined in 37 children (17 males, 20 females). Mean age of patients receiving lidocaine was 3 years 7 months (SD 3y 5mo). Lidocaine administration achieved control of status epilepticus in 19 of 53 convulsive episodes (35.8%). Seizures ceased within 5 minutes of lidocaine administration in all 19 patients who were responsive to the drug. Regarding aetiology of status epilepticus and types of seizures, there was no statistical difference in effectiveness. Mild decrease of oxygen saturation, monitored by pulse oximetry, was observed in one patient, which improved by oxygenation using a mask. Lidocaine is a useful anticonvulsive agent; however, the response rate to lidocaine appears to be quite low, as less than half of the seizures were effectively controlled by lidocaine. Favourable properties of the drug include prompt responses, less alteration of consciousness, and fewer adverse effects, including less respiratory depression. [source] Bispectral Electroencephalographic Analysis of Patients Undergoing Procedural Sedation in the Emergency DepartmentACADEMIC EMERGENCY MEDICINE, Issue 6 2003James R. Miner MD Abstract Objective: To determine whether there is a correlation between the level of sedation achieved during procedural sedation (PS) in the emergency department as determined by bispectral electroencephalographic (EEG) analysis (BIS) and the rate of respiratory depression (RD), the patient's perception of pain, recall of the procedure, and satisfaction. Methods: This was a prospective observational study conducted in an urban county hospital of adult patients undergoing PS using propofol, methohexital, etomidate, and the combination of fentanyl and midazolam. Consenting patients were monitored by vital signs, pulse oximetry, nasal-sample end-tidal carbon dioxide (ETCO2), and BIS monitors during PS. Respiratory depression (RD) was defined as an oxygen saturation <90%, a change from baseline ETCO2 of >10 mm Hg, or an absent ETCO2 waveform at any time during the procedure. After the procedure, patients were asked to complete three 100-mm visual analog scales (VASs) concerning their perception of pain, recall of the procedure, and satisfaction with the procedure. Patients were divided into four groups based on the lowest BIS score recorded during the procedure, group 1, >85; group 2, 70,85; group 3, 60,69; group 4, <60. Rates of RD and VAS outcomes were compared between groups using chi-square statistics. Results: One hundred eight patients were enrolled in the study. No serious adverse events were noted. RD was seen in three of 14 (21.4%) of the patients in group 1, seven of 34 (20.6%) in group 2, 16 of 26 (61.5%) in group 3, and 18 of 34 (52.9%) in group 4. The rate of RD in patients in group 2 was not significantly different from that in group 1 (p = 0.46). The rate of RD in group 2 was significantly lower than that in groups 3 (p = 0.0003) and 4 (p = 0.006). For the VAS data, when group 1 was compared with the combined groups 2, 3, and 4, it had significantly higher rates of pain (p = 0.003) and recall (p = 0.001), and a dissatisfaction rate (p = 0.085) that approached significance. When groups 2, 3, and 4 were compared with chi-square test, there was not a significant difference in pain (p = 0.151), recall (p = 0.27), or satisfaction (p = 0.25). Conclusions: Patients with a lowest recorded BIS score between 70 and 85 had the same VAS outcomes as more deeply sedated patients and the same rate of RD as less deeply sedated patients. This range of scores represented the optimally sedated patients in this study. [source] Determination of pulp vitality in vivo with pulse oximetryINTERNATIONAL ENDODONTIC JOURNAL, Issue 9 2008E. Calil Abstract Aim, To evaluate the use of pulse oximetry as a test for pulp vitality, by comparing in the same patient, the levels of oxygen saturation of the index finger and of the maxillary central incisor and canine teeth without clinically detectable pulp inflammation. Methodology, Seventeen male and female patients aged between 26 and 38 years participated and a total of 32 maxillary central incisor and 32 canine teeth were analysed. Selection criteria required the teeth to have healthy crowns, or with restorations no more than 2 mm in diameter and no clinical and radiographical signs or symptoms of pulp or periapical inflammatory changes. The negative control group consisted of 10 root filled teeth. Measurements were first taken from the index finger of patients. Their teeth were then subjected to a thermal test with refrigerant gas and then to a vitality test with pulse oximetry. Data were analysed by Pearson's and paired t- tests. Results, There were no significant statistical correlations between blood oxygen levels in the index finger and in the teeth of the patient (P > 0.05). There was a statistically significant difference in the oxygen levels between the two tooth groups studied and the index finger (P , 0.002). Mean oxygen values in the index finger of patients were 95% (SD = 1.6), oxygen values in the maxillary central incisor were 91.29% (SD = 2.61) and mean oxygen values in maxillary canine were 90.69% (SD = 2.71). Conclusion, The method determined consistently the level of blood oxygen saturation of the pulp in maxillary central incisor and canine teeth and can therefore be used for pulp vitality testing. Further studies are required to assess the effectiveness and validity of pulse oximetry in determining pulp vitality in traumatized teeth. [source] The role of nurses in preventing adverse events related to respiratory dysfunction: literature reviewJOURNAL OF ADVANCED NURSING, Issue 6 2005Julie Considine BN MN RN RM FRCNA Aims., This paper reports a literature review examining the relationship between specific clinical indicators of respiratory dysfunction and adverse events, and exploring the role of nurses in preventing adverse events related to respiratory dysfunction. Background., Adverse events in hospital are associated with poor patient outcomes such as increased mortality and permanent disability. Many of these adverse events are preventable and are preceded by a period during which the patient exhibits clearly abnormal physiological signs. The role of nurses in preserving physiological safety by early recognition and correction of physiological abnormality is a key factor in preventing adverse events. Methods., A search of the Medline and CINAHL databases was conducted using the following terms: predictors of poor outcome, adverse events, mortality, cardiac arrest, emergency, oxygen, supplemental oxygen, oxygen therapy, oxygen saturation, oxygen delivery, assessment, patient assessment, physical assessment, dyspnoea, hypoxia, hypoxaemia, respiratory assessment, respiratory dysfunction, shortness of breath and pulse oximetry. The papers reviewed were research papers that demonstrated a relationship between adverse events and various clinical indicators of respiratory dysfunction. Results., Respiratory dysfunction is a known clinical antecedent of adverse events such as cardiac arrest, need for medical emergency team activation and unplanned intensive care unit admission. The presence of respiratory dysfunction prior to an adverse event is associated with increased mortality. The specific clinical indicators involved are alterations in respiratory rate, and the presence of dyspnoea, hypoxaemia and acidosis. Conclusions., The way in which nurses assess, document and use clinical indicators of respiratory dysfunction is influential in identifying patients at risk of an adverse event and preventing adverse events related to respiratory dysfunction. If such adverse events are to be prevented, nurses must not only be able to recognise and interpret signs of respiratory dysfunction, but must also take responsibility for initiating and evaluating interventions aimed at correcting respiratory dysfunction. [source] Comparison between intubation and the laryngeal mask airway in moderately obese adultsACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 4 2009M. ZOREMBA Background: Obesity is a well-established risk factor for perioperative pulmonary complications. Anaesthetic drugs and the effect of obesity on respiratory mechanics are responsible for these pathophysiological changes, but tracheal intubation with muscle relaxation may also contribute. This study evaluates the influence of airway management, i.e. intubation vs. laryngeal mask airway (LMA), on postoperative lung volumes and arterial oxygen saturation in the early postoperative period. Methods: We prospectively studied 134 moderately obese patients (BMI 30) undergoing minor peripheral surgery. They were randomly assigned to orotracheal intubation or LMA during general anaesthesia with mechanical ventilation. Premedication, general anaesthesia and respiratory settings were standardized. While breathing air, we measured arterial oxygen saturation by pulse oximetry. Inspiratory and expiratory lung function was measured preoperatively (baseline) and at 10 min, 0.5, 2 and 24 h after extubation, with the patient supine, in a 30° head-up position. The two groups were compared using repeated-measure analysis of variance (ANOVA) and t -test analysis. Statistical significance was considered to be P<0.05. Results: Postoperative pulmonary mechanical function was significantly reduced in both groups compared with preoperative values. However, within the first 24 h, lung function tests and oxygen saturation were significantly better in the LMA group (P<0.001; ANOVA). Conclusions: In moderately obese patients undergoing minor surgery, use of the LMA may be preferable to orotracheal intubation with respect to postoperative saturation and lung function. [source] The use of pulse oximetry in patients with poor peripheral perfusionACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 3 2009S. M. Neustein No abstract is available for this article. [source] Effect of dexmedetomidine on the characteristics of bupivacaine in a caudal block in pediatricsACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 2 2009I. SAADAWY Background: Dexmedetomidine (DEX) is a highly selective ,2 -adrenoceptor agonist that has been used increasingly in children. However, the effect of caudal DEX has not been evaluated before in children. This prospective randomized double-blinded study was designed to evaluate the analgesic efficacy of caudal DEX with bupivacaine in providing pain relief over a 24-h period. Methods: Sixty children (ASA status I) aged 1,6 years undergoing unilateral inguinal hernia repair/orchidopexy were allocated randomly to two groups (n=30 each). Group B received a caudal injection of bupivacaine 2.5 mg/ml, 1 ml/kg; Group BD received the same dose of bupivacaine mixed with DEX 1 ,g/kg during sevoflurane anesthesia. Processed electroencephalogram (bispectral index score), heart rate, blood pressure, pulse oximetry and end-tidal sevoflurane were recorded every 5 min. The characteristics of emergence, objective pain score, sedation score and quality of sleep were recorded post-operatively. Duration of analgesia and requirement for additional analgesics were noted. Results: The end-tidal sevoflurane concentration and the incidence of agitation were significantly lower in the BD group (P<0.05). The duration of analgesia was significantly longer (P<0.001) and the total consumption of rescue analgesic was significantly lower in Group BD compared with Group B (P<0.01). There was no statistically significant difference in hemodynamics between both groups. However, group BD had better quality of sleep and a prolonged duration of sedation (P<0.05). Conclusion: Caudal DEX seems to be a promising adjunct to provide excellent analgesia without side effects over a 24-h period. It has the advantage of keeping the patients calm for a prolonged time. Implications statement: Caudally administered DEX (1 ,g/kg), combined with bupivacaine, was associated with an extended duration of post-operative pain relief. [source] Deceptive simplicity: Systemic oxygen delivery and pulse oximetryJOURNAL OF PAEDIATRICS AND CHILD HEALTH, Issue 7-8 2007Clare L Collins Abstract: Pulse oximetry is often perceived to be a measure of the adequacy of oxygen delivery. It is, however, only a measure of oxygen bound to haemoglobin. Systemic oxygen delivery is principally determined by cardiac output, haemoglobin concentration and haemoglobin saturation. Changes to both cardiac output and haemoglobin concentration will significantly alter oxygen delivery without changing oxygen saturation. This article will describe the components of systemic oxygen delivery and the physiologic limitation of pulse oximetry and caution against over-interpretation of oximetry in the care of newborns. [source] Respiration can be monitored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory modeACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 8 2005L. Nilsson Background:, Photoplethysmography (PPG) is a non-invasive optical technique used, for instance, in pulse oximetry. Beside the pulse synchronous component, PPG has a respiratory synchronous variation (PPGr). Efforts have been made to utilize this component for indirect monitoring of respiratory rate and volume. Assessment of the clinical usefulness as well as of the physiological background of PPGr is required. We evaluated if anaesthesia and positive-pressure ventilation would affect PPGr. Methods:, We recorded reflection mode PPGr, at the forearm, and the respiratory synchronous changes in central venous pressure (CVP), peripheral venous pressure (PVP) and arterial blood pressure (ABP) in 12 patients. Recordings for each patient were made on three occasions: awake with spontaneous breathing; anaesthetized with spontaneous breathing; and anaesthetized with positive-pressure ventilation. We analyzed the sensitivity, specificity, coherence and time relationship between the signals. Results:, PPGr sensitivity for breath detection was [mean (SD)] >86(21)% and specificity >96(12)%. Respiratory detection in the macrocirculation (CVP, PVP and ABP) showed a sensitivity >83(29)% and specificity >93(12)%. The coherence between signals was high (0.75,0.99). The three measurement situations did not significantly influence sensitivity, specificity or time shifts between the PPGr, PVP, ABP, and the reference CVP signal despite changes in physiological data between measurements. Conclusion:, A respiratory synchronous variation in PPG and all invasive pressure signals was detected. The reflection mode PPGr signal seemed to be a constant phenomenon related to respiration regardless of whether or not the subject was awake, anaesthetized or ventilated, which increases its clinical usefulness in respiratory monitoring. [source] Cost-effectiveness of screening for hepatopulmonary syndrome in liver transplant candidates,LIVER TRANSPLANTATION, Issue 2 2007D. Neil Roberts The hepatopulmonary syndrome (HPS) is present in 15,20% of patients with cirrhosis undergoing orthotopic liver transplantation (OLT) evaluation. Both preoperative and post-OLT mortality is increased in HPS patients particularly when hypoxemia is severe. Screening for HPS could enhance detection of OLT candidates with sufficient hypoxemia to merit higher priority for transplant and thereby decrease mortality. However, the cost-effectiveness of such an approach has not been assessed. Our objective was to perform a cost-effectiveness analysis from a third-party payer's perspective of screening for HPS in liver OLT candidates. The costs and outcomes of 3 different strategies were compared: (1) no screening, (2) screening patients with a validated dyspnea questionnaire, and (3) screening all patients with pulse oximetry. Arterial blood gas analyses and contrast echocardiography were performed in patients with dyspnea or a pulse oximetry (SpO2) ,97% to define the presence of HPS. A Markov model was constructed simulating the natural history of cirrhosis in a cohort of patients 50 years old over a time horizon of their remaining life expectancy. Transition probabilities were obtained from published data available through Medline and U.S. vital statistics. Costs represented Medicare reimbursement data at our institution. Costs and health effects were discounted at a 3% annual rate. No screening was associated with a total cost of $291,898 and a life expectancy of 11.131 years. Screening with pulse oximetry was associated with a cost of $299,719 and a life expectancy of 12.27 years. Screening patients with the dyspnea-fatigue index was associated with a cost and life expectancy of $300,278 and 12.28 years, respectively. The incremental cost-effectiveness ratio of screening with pulse oximetry (compared to no screening) was $6,867 per life year gained, whereas that of the dyspnea-fatigue index (compared to pulse oximetry) was $55,900 per life year gained. The cost-effectiveness of screening depended on the prevalence and severity of HPS, and the choice of screening strategy was dependent on the sensitivity of the screening modality. In conclusion, screening for HPS, especially with pulse oximetry, is a cost-effective strategy that improves survival in transplant candidates predominantly by targeting the transplant to the subgroup of patients most likely to benefit. The utility of screening depends on the prevalence and severity of HPS in the target population. Liver Transpl, 2006. © 2006 AASLD. [source] Utility of pulse oximetry in the detection of arterial hypoxemia in liver transplant candidatesLIVER TRANSPLANTATION, Issue 4 2002Gary A. Abrams MD Assistant Professor of Medicine Hepatopulmonary syndrome, arterial hypoxemia caused by intrapulmonary vasodilatation, occurs in approximately 10% of patients with cirrhosis. The severity of hypoxemia affects liver transplant candidacy and is associated with increased morbidity and mortality posttransplantation. Screening guidelines for detecting the presence of arterial hypoxemia do not exist. The aim of this study is to investigate the accuracy and utility of pulse oximetry in the detection of hypoxemia (PaO2 < 70 mm Hg) in patients with cirrhosis. Two hundred prospective liver transplant candidates were compared with 94 controls. Arterial oxyhemoglobin saturation was obtained by pulse oximetry (SpO2) and compared with simultaneous arterial blood gas (ABG) oxyhemoglobin values (SaO2; bias = the difference). PaO2, carboxyhemoglobin, methemoglobin, and routine clinical and biochemical parameters were investigated to account for the bias. SpO2 overestimated SaO2 in 98% of patients with cirrhosis (mean bias, 3.37%; range, ,1% to 10%). Forty-four percent of patients with cirrhosis and controls had a bias of 4% or greater. No clinical or biochemical parameters of cirrhosis accounted for the overestimation of pulse oximetry. Twenty-five subjects with cirrhosis were hypoxemic, and an SpO2 of 97% or less showed a sensitivity of 96% and a positive likelihood ratio of 3.9 for detecting hypoxemia. An SpO2 of 94% or less detected all subjects with an arterial PaO2 less than 60 mm Hg. Pulse oximetry significantly overestimates arterial oxygenation, and the inaccuracy is not influenced by liver disease. Nevertheless, pulse oximetry can be a useful screening tool to detect arterial hypoxemia in patients with cirrhosis, but a higher threshold for obtaining an ABG must be used. [source] Continuous spinal analgesia for labor and delivery in a parturient with hypertrophic obstructive cardiomyopathyACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 3 2002T. Okutomi Induction of labor under analgesia was planned for a 30-year-old-primiparous patient with hypertrophic obstructive cardiomyopathy (HOCM), as her fetal evaluation revealed intrauterine growth restriction at 38 weeks' gestation. However, regional analgesia during labor may present a potential risk for hemodynamic instability in patients with HOCM due to the possibility of a sympathetic block, as a result of vasodilation associated with the administration of local anesthesia. This case report demonstrates the successful management of the patient with analgesia provided by a continuous spinal catheter dosed with a continuous infusion of fentanyl and supplemental meperidine. Fetal surveillance monitoring included fetal pulse oximetry in addition to conventional cardiotocography, on the basis of which cesarean section was avoided. [source] Longtime performance and reliability of two different PtcCO2 and SpO2 sensors in neonatesPEDIATRIC ANESTHESIA, Issue 9 2008VERA BERNET Summary Objectives:, Blood gas monitoring is necessary in treatment of critically ill neonates. Whereas SaO2 can be estimated by pulse oximetry, PaCO2 is still most often assessed from blood samples. Aim:, To compare long time performance of an ear sensor for combined assessment of transcutaneous carbon dioxide (PtcCO2) and oxygen saturation (SpO2) (TOSCA Monitor; Radiometer, Switzerland) with a conventional PtcCO2 monitor (MicroGas 7650-500 rapid, Radiometer, Switzerland) in critically ill neonates. Methods:, Prospective, observational study. Twenty critically ill neonates were monitored for PtcCO2 and SpO2 using the Tosca and the MicroGas monitor for 24 h. TOSCA ear sensor was changed to the other ear lobe after 12 h and the MicroGas sensor four hourly on the trunk. Values obtained were compared with SaO2 and PaCO2 from arterial blood gas analysis using Bland,Altman analysis. Data are presented as median (range). Results:, Eighty-two paired measurements were obtained. Median age of the 20 patients was 4.5 days (1,26 days) and weight was 3.05 kg (0.98,3.95 kg). Bias and precision between PaCO2 and PtcCO2 were 0.14 and 1.45 kPa for the Tosca monitor and ,0.08 and 1.2 kPa for the MicroGas monitor, respectively. The two biases were significantly different (P = 0.0036). SpO2 assessment by TOSCA was comparable to SaO2 values (bias 0.26% and precision 4.14%). Conclusion:, The TOSCA monitor allows safe estimation of PtcCO2 and SaO2 in neonates. Measurements of PtcCO2 were less reliable with TOSCA compared with conventional monitoring but still allow assessing a trend of ventilation status in newborn patients. [source] Cerebral oximetry improves detection of sickle cell patients at risk for nocturnal cerebral hypoxia,PEDIATRIC PULMONOLOGY, Issue 11 2006Ashok B. Raj MD Abstract We previously used cerebral oximetry to identify low cerebral venous oxygen saturation in waking children with sickle cell disease (SCD). Because arterial oxyhemoglobin desaturation is common during sleep in SCD patients, this study compared both waking and sleeping systemic arterial and cerebral venous oxygenation dynamics in children with and without SCD. Seventeen African-American (AA) children with homozygous SCD [8 (4,15) years; 29% male; normal transcranial Doppler velocities] were compared with a control cohort (CON) comprised of six healthy AA children [9 (4,16) years, 33% male]. Standard all-night polysomnographic recordings were performed, including measurement of arterial oxygen saturation by pulse oximetry (SpO2). Regional cerebral oxygen saturation (rSO2) was measured non-invasively with cerebral oximetry. Intra-cohort comparisons examined the influence of sleep on SpO2 and rSO2 in the subjects. Inter-cohort comparisons of SpO2, rSO2, and the rSO2/SpO2 ratio assessed the impact of SCD on systemic and cerebral oxygenation during wakefulness and sleep. Cohort differences in SpO2 were not statistically significant in either wakefulness or sleep. However, only in the SCD cohort was the magnitude of SpO2 change statistically significant (P,=,0.002). In contrast, both waking and sleep rSO2 cohort median values did differ significantly [awake: CON 76 (67,86) vs. SCD 62 (58,71), P,=,0.01; sleep: CON 65 (60,77) vs. SCD 55 (48,61), P,=,0.01)]. The waking rSO2/SpO2 ratio was also significantly lower in the SCD group [CON 0.78 (0.68,0.88) vs. SCD of 0.66 (0.61,0.72); P,=,0.015]. During sleep, the ratio was also significantly lower in the SCD group [CON 0.71 (0.66,0.81) vs. SCD 0.59 (0.52,0.65); P,=,0.011]. Our findings suggest that SCD patients may be at increased risk of cerebral hypoxia during both wakefulness and sleep. Pediatr Pulmonol. 2006, 41:1088,1094. © 2006 Wiley-Liss, Inc. [source] Episodes of hypoxemia during synchronized intermittent mandatory ventilation in ventilator-dependent very low birth weight infantsPEDIATRIC PULMONOLOGY, Issue 1 2005Steve R.E. Firme MD Abstract Distinct patterns of asynchrony, and episodes of hypoxemia, may occur in a spontaneously breathing preterm infant during conventional intermittent mandatory ventilation (IMV) on traditional time-cycled, pressure-limited ventilators. Synchronized IMV (SIMV) and assist/control ventilation are frequent modes of patient-triggered ventilation used with infant ventilators. The objective of this study was to use computerized pulse oximetry to quantify the occurrence of episodes of hypoxemia (oxygen desaturation) during SIMV vs. IMV, in preterm infants ,1,250 g who required mechanical ventilation at ,14 days of age. We performed a randomized, crossover study with each infant being randomized to IMV or SIMV (Infant Star ventilator) for initial testing for a 1-hr period. Patients were subsequently tested on the alternate modality after a stabilization period of 10 min at the same ventilator and fractional inspired oxygen concentration (FiO2) settings. Pulse oximetry data were obtained with a Nellcor N-200 monitor, a microcomputer, and a software program (SatMaster). An investigator blinded to the randomized assignment evaluated all measurements. Eighteen very low birth weight (VLBW) infants with a birth weight of 777,±,39 g (mean,±,SEM) and gestational age 25.1,±,0.3 weeks were studied. The average pulse oximeter oxygen saturation (SaO2) was higher on SIMV than IMV (P,<,0.01). During SIMV, these infants had significantly fewer episodes of hypoxemia (duration of episodes of oxygen desaturation as a percentage of scorable recording time) to 86,90% SaO2 (P,<,0.01), 81,85% SaO2 (P,<,0.01), and 76,80% SaO2 (P,<,0.05) when compared to IMV. There was also a significant decrease in percentage of time of desaturation to SaO2,<,90% (P,=,0.002),,<,85% SaO2 (P,=,0.003), and <80% SaO2 (P,=,0.02) during SIMV vs. IMV. Our preliminary findings indicate that the use of SIMV in a population of VLBW ventilator-dependent infants (,14 days of age) results in better oxygenation and decreased episodes of hypoxemia as compared to IMV. © 2005 Wiley-Liss, Inc. [source] Pulmonary sequelae in long-term survivors of bronchopulmonary dysplasiaPEDIATRICS INTERNATIONAL, Issue 6 2000Daniel Kwok-Keung Ng AbstractBackground: Bronchopulmonary dysplasia (BPD) is a common problem in premature babies. Long-term sequelae are the main concerns. Methods: A retrospective review of all BPD children born in Queen Mary Hospital, a teaching hospital of the University of Hong Kong, from January 1987 to December 1995 was conducted. Children with cerebral palsy, immunodeficiency, congenital heart disorders, renal or liver failure were excluded from analysis. Chest radiography (CXR), electrocardiogram (ECG) and pulse oximetry were routinely performed. Results: Fifty-five children completed the study. The female to male ratio was 1 : 1.1. The mean gestational age was 28 weeks. Twenty-five children were born with a birthweight of less than 1001 g. Mean age at assessment was 5.4 years. Twenty-four children (44%) demonstrated signs or symptoms of current asthma. Only seven children managed to perform the spirometry satisfactorily. One child had low forced vital capacity and one had hyperresponsive airway. The only risk factor found to be associated with current asthma was the birth month, with those children born early in the year at higher risk of developing current asthma. Seventeen of 48 children (35%) had a bodyweight below the third percentile at the corrected age of 1 year. Eleven of these seventeen children (65%) demonstrated catch-up growth at assessment. Abnormal CXR was found in 25 of 40 children (63%). All had normal pulse oximetry and ECG. Conclusions: Bronchopulmonary dysplasia children had a significantly higher risk than the general population of developing current asthma (odds ratio 4.7; 95% confidence interval 3.4,6.5; P<0.0001). The importance of birth month suggests that early life experience is important in the pathogenesis of asthma, even in BPD children. The long-term growth of BPD children was much better than previously reported. [source] Decreased oxygen saturation as a result of haemoglobin TitusvilleTHE CLINICAL RESPIRATORY JOURNAL, Issue 4 2008H. Avellan-Hietanen Abstract Introduction:, Our patient was admitted to the hospital due to shortness of breath. Although partial pressure of oxygen in arterial blood was normal, oxygen saturation measured with pulse oximetry (SpO2) was markedly decreased. SpO2 and oxygen saturation of arterial blood (SaO2) stayed low during monitoring even with an increased fraction of oxygen in inspired air. Methods:, Report of a case. Results:, After extensive investigations, a rare haemoglobin variant, haemoglobin Titusville, with decreased oxygen binding capacity was discovered. This is the first haemoglobin Titusville case reported in Scandinavian countries. Please cite this paper as: Avellan-Hietanen H, Aittomaki J, Ekroos H, Aittomäki K, Turpeinen U, Kalkkinen N and Sovijärvi A. Decreased oxygen saturation as a result of haemoglobin Titusville. The Clinical Respiratory Journal 2008; 2: 242,244. [source] Global oximetry: an international anaesthesia quality improvement projectANAESTHESIA, Issue 10 2009I. A. Walker Summary Pulse oximetry is mandatory during anaesthesia in many countries, a standard endorsed by the World Health Organization ,Safe Surgery Saves Lives' initiative. The Association of Anaesthetists of Great Britain and Ireland, the World Federation of Societies of Anaesthesiologists and GE Healthcare collaborated in a quality improvement project over a 15-month period to investigate pulse oximetry in four pilot sites in Uganda, Vietnam, India and the Philippines, using 84 donated pulse oximeters. A substantial gap in oximeter provision was demonstrated at the start of the project. Formal training was essential for oximeter-naïve practitioners. After introduction of oximeters, logbook data were collected from over 8000 anaesthetics, and responses to desaturation were judged appropriate. Anaesthesia providers believed pulse oximeters were essential for patient safety and defined characteristics of the ideal oximeter for their setting. Robust systems for supply and maintenance of low-cost oximeters are required for sustained uptake of pulse oximetry in low- and middle-income countries. [source] Successful use of pharyngeal pulse oximetry with the oropharyngeal airway in severely shocked patientsANAESTHESIA, Issue 7 2007H. Yu Summary We describe the successful use of pharyngeal oximetry with the oropharyngeal airway in two patients with severe shock in whom finger pulse oximetry failed. One patient was a 50-year-old man with septic shock and the other a 32-year-old woman with haemorrhagic shock. In both patients, an oropharyngeal airway with a paediatric pulse oximeter probe was inserted adjacent to the tracheal tube. A good waveform was obtained and oxygen saturation was 0,2% lower than arterial samples whereas finger pulse oximetry saturation was unobtainable or much lower than arterial oxygen saturation. Pharyngeal oxygen saturation with the oropharyngeal airway is feasible and more accurate than finger oximetry in low perfusion states. [source] An unusual problem with pulse oximetryANAESTHESIA, Issue 1 2003R Spencer No abstract is available for this article. [source] Randomized Clinical Trial of Propofol With and Without Alfentanil for Deep Procedural Sedation in the Emergency DepartmentACADEMIC EMERGENCY MEDICINE, Issue 9 2009James R. Miner MD Abstract Objectives:, The objectives were to compare the efficacy, occurrence of adverse events, and recovery duration of propofol with and without alfentanil for use in procedural sedation in the emergency department (ED). Methods:, This was a randomized nonblinded prospective trial of adult patients undergoing procedural sedation for painful procedures in the ED. Patients with pain before the procedure were given intravenous (IV) morphine sulfate until their pain was adequately treated at least 20 minutes before starting the procedure. Patients received 1 mg/kg propofol either with or without a supplemental dose of 10 ,g/kg alfentanil for deep procedural sedation. Doses, vital signs, nasal end-tidal CO2 (ETCO2), pulse oximetry, and bispectral electroencephalographic (EEG) analysis scores were recorded. Subclinical respiratory depression was defined as a change in ETCO2 of >10 mmHg, an oxygen saturation of <92% at any time, or an absent ETCO2 waveform at any time. Clinical events related to respiratory depression were noted during the procedure, including the addition of or increase in the flow rate of supplemental oxygen, the use of a bag-valve mask apparatus, airway repositioning, or stimulation to induce breathing. After the procedure, patients were asked if they experienced pain during the procedure or had recall of the procedure. Results:, A total of 150 patients were enrolled; 146 underwent sedation and were included in the analysis. Seventy-four patients received propofol, and 71 received propofol with alfentanil. No clinically significant complications were noted. Subclinical respiratory depression was seen in 24/74 patients in the propofol group and 30/71 patients in the propofol/alfentanil group (effect size = 9.8%, 95% CI = ,5.8% to 25.5%). Clinical signs of respiratory depression included an increase in supplemental oxygen use in 25 of the 74 propofol patients and 31 of the 71 propofol/alfentanil patients (effect size 9.9%, 95% CI = ,5.9% to 25.7%), the use of bag-valve mask apparatus in seven patients in the propofol group and 12 in the propofol/alfentanil group (effect size = 5.6%, 95% CI = ,3.5% to 18.4%), airway repositioning in 13 propofol patients and 20 propofol/alfentanil patients (effect size = 10.6%, 95% CI = ,3.0% to 24.2%), and stimulation to induce breathing in 11 propofol patients and 20 propofol/alfentanil patients (effect size = 13.3%, 95% CI = 0.1% to 26.5%). The total time of the procedure was longer for the alfentanil/propofol group (median = 11 minutes, range = 5,22 minutes) than for the propofol group (median = 9 minutes, range = 1 to 43 minutes; effect size = 1.93 minutes, 95% CI = 0.73 to 2.58, p = 0.02). Pain during the procedure was reported by 10 of the 74 patients in the propofol group and 7 of the 71 patients in the propofol/alfentanil group (effect size = 4.5%, 95% CI = ,6.8% to 14.1%). Recall of some part of the procedure was reported by 12 patients in the propofol group and 9 in the propofol/alfentanil group (effect size = 3.5%, 95% CI = ,7.9% to 15.0%). All procedures were successfully completed. Conclusions:, The use of supplemental alfentanil with propofol for procedural sedation did not result in a difference in reported pain or recall immediately after the procedure. There was an increase in the proportion of patients who required stimulation to induce respiration during the procedure in patients who received propofol with supplemental alfentanil. The addition of supplemental opioid to procedural sedation with propofol does not appear beneficial. [source] Racial and Sex Differences in Emergency Department Triage Assessment and Test Ordering for Chest Pain, 1997,2006ACADEMIC EMERGENCY MEDICINE, Issue 8 2010Lenny López MD ACADEMIC EMERGENCY MEDICINE 2010; 17:801,808 © 2010 by the Society for Academic Emergency Medicine Abstract Objectives:, This study assessed whether sociodemographic differences exist in triage assignment and whether these differences affect initial diagnostic testing in the emergency department (ED) for patients presenting with chest pain. Methods:,A nationally representative ED data sample for all adults (,18 years) was obtained from the National Hospital Ambulatory Health Care Survey of EDs for 1997,2006. Weighted logistic regression was used to examine the associations between race and presenting symptom, triage assignment, and test ordering, adjusting for patient and hospital characteristics. Results:, Over 10 years, an estimated 78 million visits to the ED presented with a complaint of chest pain. Of those presenting with chest pain, African Americans (odds ratio [OR] = 0.70; 99% confidence interval [CI] = 0.53 to 0.92), Hispanics (OR = 0.74; 99% CI = 0.51to 0.99), Medicaid patients (OR = 0.72; 99% CI = 0.54 to 0.94), and uninsured patients (OR = 0.65; 99% CI = 0.51 to 0.84) were less likely to be triaged emergently. African Americans (OR = 0.86; 99% CI = 0.70 to 0.99), Medicaid patients (OR = 0.70; 99% CI = 0.55 to 0.88), and uninsured patients (OR = 0.70; 99% CI = 0.55 to 0.89) were less likely to have an electrocardiogram (ECG) ordered. African Americans (OR = 0.69; 99% CI = 0.49 to 0.97), Medicaid patients (OR = 0.67; 99% CI = 0.47 to 0.95), and uninsured patients (OR = 0.66; 99% CI = 0.44 to 0.96) were less likely to have cardiac enzymes ordered. Similarly, African Americans and Hispanics were less likely to have a cardiac monitor and pulse oximetry ordered, and Medicaid and uninsured patients were less likely to have a cardiac monitor ordered. Conclusions:, Persistent racial, sex, and insurance differences in triage categorization and basic cardiac testing exist. Eliminating triage disparities may affect "downstream" clinical care and help eliminate observed disparities in cardiac outcomes. [source] Update on intrapartum fetal pulse oximetryAUSTRALIAN AND NEW ZEALAND JOURNAL OF OBSTETRICS AND GYNAECOLOGY, Issue 2 2002Christine E East ABSTRACT This article examines the current status of fetal pulse oximetry (FPO) as a means of intrapartum assessment of fetal wellbeing. FPO has been developed to a stage where it is a safe and accurate indicator of intrapartum fetal oxygenation. In general, sliding the FPO sensor along the examiner's fingers and through the cervix, to lie alongside the fetal cheek or temple is easy. The recent publication of a randomized controlled trial (RCT) of FPO versus conventional intrapartum monitoring has validated its use to reduce caesarean section rates for nonreassuring fetal status. An Australian multicentre RCT is currently underway. Maternal satisfaction rates with FPO are high. FPO may be used during labour when the electronic fetal heart rate trace is nonreassuring or when conventional monitoring is unreliable, such as with fetal arrhythmias. If the fetal oxygen saturation (FSpO2) values are < 30%, prompt obstetric intervention is indicated, such as fetal scalp blood sampling or delivery. FSpO2 monitoring should not form the sole basis of intrapartum fetal welfare assessment. Rather, the whole clinical picture should be considered. [source] |