PRESS Sequence (press + sequence)

Distribution by Scientific Domains


Selected Abstracts


Implementation of three-dimensional wavelet encoding spectroscopic imaging: In vivo application and method comparison

MAGNETIC RESONANCE IN MEDICINE, Issue 1 2009
Richard Young
Abstract We have recently proposed a two-dimensional Wavelet Encoding-Spectroscopic Imaging (WE-SI) technique as an alternative to Chemical Shift Imaging (CSI), to reduce acquisition time and crossvoxel contamination in magnetic resonance spectroscopic imaging (MRSI). In this article we describe the extension of the WE-SI technique to three dimensions and its implementation on a clinical 1.5 T General Electric (GE) scanner. Phantom and in vivo studies are carried out to demonstrate the usefulness of this technique for further acquisition time reduction with low voxel contamination. In wavelet encoding, a set of dilated and translated prototype functions called wavelets are used to span a localized space by dividing it into a set of subspaces with predetermined sizes and locations. In spectroscopic imaging, this process is achieved using radiofrequency (RF) pulses with profiles resembling the wavelet shapes. Slice selective excitation and refocusing RF pulses, with single-band and dual-band profiles similar to Haar wavelets, are used in a modified PRESS sequence to acquire 3D WE-SI data. Wavelet dilation and translation are achieved by changing the strength of the localization gradients and frequency shift of the RF pulses, respectively. The desired spatial resolution in each direction sets the corresponding number of dilations (increases in the localization gradients), and consequently, the number of translations (frequency shift) of the Haar wavelets (RF pulses), which are used to collect magnetic resonance (MR) signals from the corresponding subspaces. Data acquisition time is reduced by using the minimum recovery time (TRmin), also called effective time, when successive MR signals from adjacent subspaces are collected. Inverse wavelet transform is performed on the acquired data to produce metabolite maps. The proposed WE-SI method is compared in terms of acquisition time, pixel bleed, and signal-to-noise ratio to the CSI technique. The study outcome shows that 3D WE-SI provides accurate results while reducing both acquisition time and voxel contamination. Magn Reson Med 61:6,15, 2009. © 2008 Wiley-Liss, Inc. [source]


Pitfalls and advantages of different strategies for the absolute quantification of N -acetyl aspartate, creatine and choline in white and grey matter by 1H-MRS

NMR IN BIOMEDICINE, Issue 10 2009
E. Malucelli
Abstract This study extensively investigates different strategies for the absolute quantitation of N -acetyl aspartate, creatine and choline in white and grey matter by 1H-MRS at 1.5,T. The main focus of this study was to reliably estimate metabolite concentrations while reducing the scan time, which remains as one of the main problems in clinical MRS. Absolute quantitation was based on the water-unsuppressed concentration as the internal standard. We compared strategies based on various experimental protocols and post-processing strategies. Data were obtained from 30 control subjects using a PRESS sequence at several TE to estimate the transverse relaxation time, T2, of the metabolites. Quantitation was performed with the algorithm QUEST using two different metabolite signal basis sets: a whole-metabolite basis set (WhoM) and a basis set in which the singlet signals were split from the coupled signals (MSM). The basis sets were simulated in vivo for each TE used. Metabolites' T2s were then determined by fitting the estimated signal amplitudes of the metabolites obtained at different TEs. Then the absolute concentrations (mM) of the metabolites were assessed for each subject using the estimated signal amplitudes and either the mean estimated relaxation times of all subjects (mean protocol, MP) or the T2 estimated from the spectra derived from the same subject (individual protocol, IP). Results showed that MP represents a less time-consuming alternative to IP in the quantitation of brain metabolites by 1H-MRS in both grey and white matter, with a comparable accuracy when performed by MSM. It was also shown that the acquisition time might be further reduced by using a variant of MP, although with reduced accuracy. In this variant, only one water-suppressed and one water-unsuppressed spectra were acquired, drastically reducing the duration of the entire MRS examination. However, statistical analysis highlights the reduced accuracy of MP when performed using WhoM, particularly at longer echo times. Copyright © 2009 John Wiley & Sons, Ltd. [source]


Which pulse sequence is optimal for myo-inositol detection at 3T?

NMR IN BIOMEDICINE, Issue 4 2009
Ileana Hancu
Abstract Optimized myo-inositol (mI) detection is important for diagnosing and monitoring a multitude of pathological conditions of the brain. Simulations are presented in this work, performed to decide which pulse sequence has the most significant advantage in terms of improving repeatability and accuracy of mI measurements at 3T over the pulse sequence used typically in the clinic, a TE,=,35,ms PRESS sequence. Five classes of pulse sequences, four previously suggested for optimized mI detection (a short TE PRESS, a Carr-Purcell PRESS sequence, an optimized STEAM sequence, an optimized zero quantum filter), and one optimized for mI detection in this work (a single quantum filter) were compared to a standard, TE,=,35,ms pulse sequence. While limiting the SNR of an acquisition to the equivalent SNR of a spectrum acquired in 5,min from an 8,cc voxel, it was found through simulations that the most repeatable mI measurements would be obtained with a Carr-Purcell sequence. This sequence was implemented in a clinical scanner, and improved mI measurements were demonstrated in vivo. Copyright © 2008 John Wiley & Sons, Ltd. [source]


Proton T2 relaxation of cerebral metabolites of normal human brain over large TE range

NMR IN BIOMEDICINE, Issue 1 2005
E. E. Brief
Abstract T2 of NAA, creatine and choline-containing compounds were measured in posterior frontal white matter and occipital grey matter in 10 healthy human volunteers. Decay curves comprised signals from eight TE times ranging from 30 to 800,ms with TR 2000,ms acquired with a PRESS sequence on a 1.5,T clinical scanner. Simulations were conducted to assess the precision of T2 estimates from decay curves comprising varying numbers and ranges of TE points. Mean and standard errors for T2s of NAA, creatine and choline-containing compounds were 300(8), 169(3) and 239(4) ms in posterior frontal white matter and 256(6), 159(8) and 249(8) ms in occipital grey matter. In vivoT2s found for choline and NAA were shorter than the T2s in the literature. The elevation of literature T2s is accounted for by the simulation results, which demonstrated that there is a bias towards lengthened T2s when T2 is measured with a maximum TE , T2. Concentration estimates are at risk of being underestimated if previously reported T2 corrections are used. Copyright © 2004 John Wiley & Sons, Ltd. [source]