Home About us Contact | |||
Preliminary Experience (preliminary + experience)
Selected AbstractsPRELIMINARY EXPERIENCE OF A PROTOTYPE FORWARD-VIEWING CURVED LINEAR ARRAY ECHOENDOSCOPE IN A TRAINING PHANTOM MODELDIGESTIVE ENDOSCOPY, Issue 2010Hiroshi Imaizumi Oblique-viewing curved linear array (OV-CLA) echoendoscopes have been widely used to perform endoscopic ultrasonography-guided fine needle aspiration and interventional endoscopic ultrasonography. Recently a prototype forward-viewing curved liner array (FV-CLA) echoendoscope was developed. In the present trial, 11 endoscopists participated in a hands-on trial and a questionnaire survey to evaluate the operation performance and visualization performance of a prototype FV-CLA scope in a phantom model designed for training of endoscopic ultrasonography. The results of our trial suggested that the FV-CLA scope is slightly inferior or equivalent to the conventional OV-CLA scope in operation performance, and that the FV-CLA scope is equivalent to the OV-CLA scope with regard to the visualization performance in a phantom model. [source] Waveform analysis of clotting test optical profiles in the diagnosis and management of disseminated intravascular coagulation (DIC)INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, Issue 6 2002C. H. Toh Summary Transmittance waveform charts the changes in light transmittance on standard coagulation assays, such as the prothrombin time (PT) and activated partial thromboplastin time (APTT). Analysis and characterization of these data on photo-optical coagulation analysers provides additional qualitative and quantitative information to that obtained using the clotting time alone. The most thoroughly evaluated clinical application is that of the biphasic APTT waveform with disseminated intravascular coagulation (DIC). The degree of waveform abnormality correlates directly with the severity of haemostatic dysfunction and allows for both the prediction and monitoring from non-overt to overt DIC. As its performance is simple and rapid, this provides the means for targeting therapeutic intervention to an earlier stage of DIC. The recent identification that the mechanism underlying the biphasic waveform is a complex that exists in vivo between C reactive protein with very low density lipoprotein, provides potentially important insights into the molecular pathogenesis of DIC. Thus, in addition to the immediate clinical utility in diagnostic practice, it has important applications as a research tool. Preliminary experience in the application of this technology to the diagnosis and management of the haemophilias and the lupus anticoagulant syndrome has also provided evidence of the power and utility of waveform analysis in essentially simple clotting assays. [source] Preliminary experience with arterial chemoembolization for hepatoblastoma and hepatocellular carcinoma in childrenPEDIATRIC BLOOD & CANCER, Issue 7 2006Piotr Czauderna MD Abstract The objective of this work was to test feasibility and efficacy of hepatic artery chemoembolization (HACE) in unresectable malignant liver tumors. Five patients aged from 1,12 years were treated in the Medical University of Gdansk from 1999 to 2002. All had locally advanced tumors, which did not respond to systemic chemotherapy: four, hepatoblastoma (HB) and one, hepatocellular carcinoma (HCC). Arteriography was performed and chemoembolization suspension (cisplatin,+,doxorubicin,+,mitomycin mixed with lipiodol) was injected, followed by gelatin foam particles. The procedure was performed one to three times in each patient. In four patients (three, HB, one, fibrolamellar HCC), tumor response was observed, with decrease in the diameter of the mass of 25,33% and fall in the AFP level of 83,99%. One child with HB was non-evaluable due to early death caused by systemic myelotoxicity. Two patients (2 HB) underwent macroscopically complete tumor resection, 1 is alive and well, and 1 died at the end of surgery for an unknown reason (possibly related to cardiotoxicity of earlier systemic chemotherapy). One HB patient was successfully transplanted after two HACE courses. The only HCC patient died because of pulmonary oil embolism immediately after the third HACE course. HACE can lead to tumor regression in most cases and may be considered an alternative for patients with unresectable liver tumors who do not respond to primary systemic chemotherapy and are not candidates for liver transplantation for various reasons. © 2005 Wiley-Liss, Inc. [source] Preliminary experience with a new 18 mm Amplatzer PFO occluder for small persistent foramen ovaleCATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, Issue 4 2003Peter Ewert MD Abstract We report our initial experience with a new 18 mm Amplatzer PFO device for the closure of small PFO. Patients were selected by a semiquantitative sizing procedure using the circle of a diagnostic pigtail catheter instead of a sizing balloon. In all eight patients, the device was easy to implant without problems. Due to its size, it has the potential to minimize the risk of inadvertent atrial erosion or perforation after deployment and thus will enhance the safety of interventional PFO closure. Cathet Cardiovasc Intervent 2003;59:518,521. © 2003 Wiley-Liss, Inc. [source] Preliminary experiences of the triple tibial osteotomy procedure: tibial morphology and complicationsJOURNAL OF SMALL ANIMAL PRACTICE, Issue 5 2009A. I. C. Renwick Objective: To document the effect of variable tibial morphology on the planning and execution of the triple tibial osteotomy (TTO) procedure in dogs and complications encountered while becoming familiar with the technique. Methods: The records of 21 consecutive cases that had a TTO performed were reviewed. Preoperative tibial morphology was assessed. Modifications in the described technique and complications were documented. Postoperative outcome was evaluated using a client-based questionnaire. Results: The size of the tibial wedge ostectomy was modified because of variable tibial morphology in four dogs (19 per cent) to avoid over or under correction of the tibial plateau angle (TPA). Intraoperatively, fracture through the caudal tibial cortex occurred in nine cases (41 per cent) and through the distal tibial crest cortex in four cases (18 per cent). Major complications occurred in five (23 per cent) of cases with four (18 per cent) requiring further surgery. The client questionnaire results demonstrated significant improvements in all parameters and no significant difference from the preinjury status. Clinical Significance: TPA measurement is recommended when planning a TTO to avoid over or under correction of the TPA. Despite frequent minor complications, it appears that the TTO is an effective procedure for management of cranial cruciate ligament rupture in the dog. [source] Contrast-enhanced peripheral MR angiography at 3.0 Tesla: Initial experience with a whole-body scanner in healthy volunteersJOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 5 2003Tim Leiner MD Abstract Purpose To report preliminary experience with contrast-enhanced magnetic resonance angiography (CE-MRA) of the peripheral arteries on a 3.0 T whole-body scanner equipped with a prototype body coil. Materials and Methods Four healthy volunteers were imaged on the 3.0 T system and, for comparative purposes, two of the subjects were also imaged on a commercially available 1.5 T whole-body system. To investigate field strength influence on objective image quality, signal-to-noise (SN) and contrast-to-noise (CN) ratios were calculated for named vessels from the infrarenal aorta to the ankles at both field strengths. Comparable imaging protocols were used at both field strengths. In addition, two reviewers, blinded for field strength, gave subjective image quality scores (three-point scale). Results SN and CN ratios were approximately equal on both systems (variation ,9%) for the iliac and proximal upper leg stations. For the popliteal and lower leg stations SN ratios were 36% and 97% higher, and CN ratios were 44% and 127% higher, at 3.0 T. Subjective image quality at 3.0 T was substantially better for the distal upper and lower legs. Conclusion Contrast-enhanced peripheral MRA is possible at 3.0 T when an imaging protocol similar to a current state-of-the-art 1.5 T protocol is used. Objective and subjective image quality at 3.0 T is comparable for the iliac and upper legs but better for the popliteal and lower leg arteries. J. Magn. Reson. Imaging 2003;17:609,614. © 2003 Wiley-Liss, Inc. [source] Monitoring free flaps using laser-induced fluorescence of indocyanine green: A preliminary experienceMICROSURGERY, Issue 7 2002C. Holm M.D. In a prospective, clinical study, the clinical utility of indocyanine green for intraoperative monitoring of free tissue transfer was evaluated. The study comprised 20 surgical patients undergoing elective microsurgical procedures. Indocyanine green angiography was performed intraoperatively, immediately after flap inset, and the operating team was blind to the fluoremetric findings. Thereafter, postoperative monitoring was done exclusively by clinical examination (color, temperature, time for recapillarization, and bleeding after puncture). Final outcome was compared with results of perioperative indocyanine (ICG)-imaging, and classified either as total flap loss, partial flap loss, or successful tissue transplantation. A total of 2 (10%) complications was recorded, and included one partial and one total flap loss. Both complications were detected by intraoperative ICG imaging. Another case of intraoperative subclinical arterial spasm at the place of microvascular anastomosis was revealed by dynamic ICG-videography. This flap did not develop postoperative complications. In conclusion, evaluation of perfusion by ICG imaging is feasible in all kinds of microsurgical flaps, irrespective of the type of tissue. Even though not meeting all the criteria of an ideal monitoring device, significant additional information can be obtained. In this study, cases with arterial spasm, venous congestion, and regional hypoperfusion were revealed by intraoperative ICG-videography. There was a strong correlation between intraoperative findings and clinical outcome. © 2002 Wiley-Liss, Inc. MICROSURGERY 22:278,287 2002 [source] Ancillary Tools in Pacemaker and Defibrillator Lead Extraction Using a Novel Lead Removal SystemPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2001ANTONIS S. MANOLIS MANOLIS, A.S., et al.: Ancillary Tools in Pacemaker and Defibrillator Lead Extraction Using a Novel Lead Removal System. A previous report described our preliminary experience with a highly successful pacing lead removal system (VascoExtor). Extending this experience, we found it necessary to use additional tools to enhance the success of percutaneous lead extraction with this system. In the present series, we used the standard locking stylets (S and K), and recently, one newer type of stylet (Magic) over the last 3 years in 34 patients to extract 48 pacemaker leads in 31 patients and 3 defibrillator (ICD) leads in 3 patients. Lead extraction was carried out in 23 men and 11 women (aged 64 ± 17 years) because of pacemaker infection (n = 21), pacemaker (n = 8) or ICD (n = 3) lead malfunction, or prior to ICD implant (n = 2). Leads were in place for 3.5 ± 3.7 years. Infections, involving pocket and lead(s), were due to S. epidermidis (n = 13), S. aureus (n = 6), S. aureus plus E. coli (n = 1), or fungi (n = 1). Of the 48 pacing leads, 31 were ventricular, 15 atrial, and 2 were VDD leads. The ICD leads were two double-coil leads (CPI) and one single-coil lead (Telectronics). Using the S (n = 12), K (n = 8), or Magic (n = 3) stylets, all pacing leads in 23 patients and the ICD leads in 2 patients were successfully removed from a subclavian approach using the locking stylets. However, in nine (26.5%) patients ancillary tools were required. In four patients, lead fragments were captured with use of a noose catheter, a pigtail catheter, and a bioptome from a right femoral approach. In two patients, locking could not be effected and a noose catheter from the right femoral vein was used, aided by a pigtail and an Amplatz catheter and a bioptome to remove three leads. In a patient with an ICD lead, a combined subclavian (stylet S) and right femoral approach (noose catheter) was required. In a patient with a dysfunctional ventricular lead 12 years old, a motor drive unit was used to facilitate the exchange of locking stylets, but extraction failed. In another patient, a fragment of a dysfunctional ventricular lead remained intravascularly despite resorting to a femoral approach. Finally, lead removal was completely (32/34, 94%) or partially (1/34, 3%) successful in 33 (97%) of 34 patients for 50 (98%) of 51 leads without complications. In conclusion, to enhance the success of pacing or ICD lead extraction with use of the VascoExtor locking stylets, an array of ancillary tools were required in more than one fourth of patients. [source] Preliminary Results with the Simultaneous Use of Implantable Cardioverter Defibrillators and Permanent Biventricular Pacemakers: Implications for Device Interaction and DevelopmentPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2000S. WALKER We report our preliminary experience with the combined use of implantable cardioverter defibrillutors (ICD) and biventricular pacemakers in six patients with heart failure and malignant ventricular arrhythmia. Two patients underwent ICD implantation for malignant ventricular arrhythmia after previous biventricular pacemaker implantation. One patient underwent biventricular pacemaker insertion for NYHA Class III heart failure after previous ICD implantation. Two patients underwent single device implantation. In the sixth patient, a combined implantation failed due to an inability to obtain a satisfactory left ventricular pacemaker lead position. The potential for device interaction was explored during implantation. In two patients a potentially serious interaction was discovered. Subsequent alterations in device configuration and programming prevented these interactions with long-term use. No complication of combined device use has been demonstrated during a mean follow-up of 2 months (range 1-4 months). Satisfactory ICD and pacemaker function has also been demonstrated. We conclude that combined device implantation may be feasible with currently available pacing technology and that further prospective studies are required in this area. [source] Bortezomib plus intermediate-dose dexamethasone and thalidomide in elderly untreated patients with multiple myeloma: A Chinese experience,AMERICAN JOURNAL OF HEMATOLOGY, Issue 7 2010Hongfeng Guo Bortezomib has proven to be active in patients with multiple myeloma (MM), including elderly patients. The aim of this study was to evaluate the efficacy and toxicity of bortezomib in combination with intermediate-dose dexamethasone (Dex) and thalidomide in untreated MM patients aged ,65 years in a Chinese single center. In this study, 18 patients were treated with bortezomib at 1.3 mg/m2 IV on Days 1, 4, 8, and 11 and Dex at 20 mg/day IV on Days 1,4 and 8,11 simultaneously. Thalidomide at dose of 100 mg/day was given everyday. The mean number of cycles of bortezomib treatment was 2.06. Three patients (17%) achieved a complete response (CR), four (22%) a very good partial response (VGPR), and nine (50%) a PR, resulting in an overall response rate of 89%. The median time to response was 22 days (range 14,50 days). The duration of response was significantly longer in patients achieving a CR/VGPR with respect to those achieving only a PR (8.5 vs. 4.2 months, P = 0.03). Grade 3,4 toxicities occurring in patients comprised weakness, thrombocytopenia, diarrhea, infection, and neuropathy. Only one patient suffered from deep vein thrombosis. This preliminary experience in Chinese patients indicated that bortezomib-Dex-thalidomide is highly effective in elderly untreated patients with MM, even in patients with poor prognostic features. Am. J. Hematol. 2010. © 2010 Wiley-Liss, Inc. [source] ORIGINAL RESEARCH,WOMEN'S SEXUAL HEALTH: Biofeedback, Electrical Stimulation, Pelvic Floor Muscle Exercises, and Vaginal Cones: A Combined Rehabilitative Approach for Sexual Dysfunction Associated with Urinary IncontinenceTHE JOURNAL OF SEXUAL MEDICINE, Issue 6 2009Massimo Rivalta MD ABSTRACT Introduction., Urinary incontinence (UI) is often associated with sexual dysfunction. We present our preliminary experience with a combined rehabilitative approach consisting of biofeedback, functional electrical stimulation, pelvic floor muscle exercises, and vaginal cones. Aim., The potential impact of such practice on UI and sexual function was analyzed in our case series and discussed. Main Outcome Measures and Methods., We evaluated three women affected by UI and sexual dysfunction. The patients underwent combined pelvic floor rehabilitation (PFR), kept voiding diaries, and filled out the Female Sexual Function Index (FSFI questionnaire) before and after the completion of PFR. We evaluated each domain score, including desire, arousal, lubrication, orgasm, satisfaction, and pain. Results., After the combined rehabilitation program, none of them had UI requiring pad use or referred urine leakage during sexual activity, including intercourse. Before PFR, FSFI score ranged from 16 to 21; after treatment, the FSFI score ranged from 22.1 to 29.3. There was an improvement in patients regarding desire, arousal, lubrication, orgasm, satisfaction, and pain. Conclusions., A complete rehabilitation can provide a beneficial effect on sexual function. A larger trial, on a more extended female population, is currently in progress, in order to confirm our findings. The effectiveness of a complete PFR scheme, together with the lack of side effects, makes it a suitable approach to sexual dysfunction that is associated with UI. Rivalta M, Sighinolfi MC, De Stefani S, Micali S, Mofferdin A, Grande M, and Bianchi G. Biofeedback, electrical stimulation, pelvic floor muscle exercises, and vaginal cones: A combined rehabilitative approach for sexual dysfunction associated with urinary incontinence. J Sex Med 2009;6:1674,1677. [source] Neoadjuvant chemoradiotherapy for operable oesophageal carcinoma: preliminary results from SheffieldBRITISH JOURNAL OF SURGERY (NOW INCLUDES EUROPEAN JOURNAL OF SURGERY), Issue 3 2001I. McL. Background: Surgical resection is the mainstay of treatment for potentially curable oesophageal carcinoma but the long-term survival rate remains 10,20 per cent. Neoadjuvant administration of chemoradiotherapy (NCR) may improve these values. In this study the authors reviewed their preliminary experience with NCR in Sheffield. Methods: Twenty-five patients with potentially resectable oesophageal carcinoma embarked on a regimen of NCR, with resection planned 4,6 weeks later. Chemotherapy incorporated two cycles of intravenous cis -platinum and 5-fluorouracil with external-beam radiotherapy administered synchronously (30,45 Gy). Results: Twenty-two of the 25 patients suffered side-effects from NCR, including one death, and seven patients failed to complete NCR as planned. The median interval from diagnosis to surgery was 121 days. Twelve out of 24 patients had significant postoperative complications, including two deaths. Seven patients had a complete histological response to NCR (three out of 15 for adenocarcinoma, four out of nine for squamous carcinoma). Conclusion: The complete histological response rate to NCR in these patients compares favourably with previous studies, as does the postoperative mortality, but this was at the expense of substantial morbidity and was associated with long delays from diagnosis to operation. At present it is not possible to predict which patients will respond favourably to NCR and whether they will benefit with improved survival. © 2001 British Journal of Surgery Society Ltd [source] Environmental liability and accident prevention: preliminary experiences in Germany,ENVIRONMENTAL POLICY AND GOVERNANCE, Issue 6 2001Reimund Schwarze Strict environmental liability, in conjunction with improved environmental liability insurance, proves to be an effective instrument to tackle environmental risks of industrial installations. This paper examines the experience with the Environmental Liability Act and Environmental Liability Insurance in Germany. It rebuts the widespread criticism of the preventive effect of the Act and considers the actual changes in the number of environmental accidents in Germany. The picture that emerges from this study is that the Act seems to have a measurable preventive effect from 1993 onwards, the year in which the new environmental liability policy was introduced. Copyright © 2001 John Wiley & Sons, Ltd and ERP Environment. [source] |