Polyimide Substrates (polyimide + substrate)

Distribution by Scientific Domains


Selected Abstracts


Ink-jet Printing and Microwave Sintering of Conductive Silver Tracks,

ADVANCED MATERIALS, Issue 16 2006
J. Perelaer
Conductive silver tracks on a polyimide substrate (see figure) are prepared by using microwave radiation to sinter silver nanoparticles printed on the substrate. This method shortens the necessary sintering time dramatically and is independent of the substrate used. Since the polymer substrate is virtually transparent to microwave radiation, a negligible amount of energy is absorbed by the substrate, whereas the conducting silver nanoparticles, with a high dielectric loss factor, strongly absorb the microwaves. [source]


Effects of uniaxial stress on the magnetic properties of thin films and GMR sensors prepared on polyimide substrates

PHYSICA STATUS SOLIDI (A) APPLICATIONS AND MATERIALS SCIENCE, Issue 8 2008
Berkem Özkaya
Abstract The effects of externally applied uniaxial stress on the magnetic properties of Co thin films and pseudo-spin-valve (PSV) structures on flexible polyimide substrates were investigated. The advantage of the polyimide substrate is its flexibility and high elasticity (,1%), which cannot be achieved using conventional crystalline substrates. The Co layers exhibit a macroscopic easy axis induced by the preparation process. When the stress is applied perpendicular to the induced in-plane easy axis, the magnetic domains in the film rotate towards the applied stress direction, which was confirmed using Kerr microscopy and magneto-optical Kerr effect (MOKE) magnetometer measurements. A Co/Cu/Ni PSV system was prepared on polyimide substrate with dc magnetron sputtering. Applying uniaxial stress leads to opposite rotation of the magnetisation directions in both layers to each other due to different signs of the magnetostriction coefficients of Co and Ni. The magnetisation and giant magnetoresistance (GMR) curves under applied stress were recorded using in situ MOKE and current in-plane four-point probe techniques, respectively. When the stress is applied perpendicular to the external magnetic field (Hext), the operating range of the GMR sensor increases, whereas the sensitivity decreases. Anisotropy energies and saturation magnetostriction values of the Co and Ni layer were determined by fitting the GMR and magnetisation curves using a micromagnetic model. (© 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim) [source]


Main-Chain Liquid Crystalline Polymers Based on Bis-Etherified 9,9-Dihexyl-2,7-bis(4,-hydroxy-1,1,-biphen-4-yl)fluorenes

MACROMOLECULAR CHEMISTRY AND PHYSICS, Issue 13 2007
Tanja Sovi
Abstract A series of liquid crystalline compounds based on 2,7-bis(biphenyl)fluorenes was synthesised by a Suzuki cross-coupling reaction and subsequent etherification with different bromoalkenes. By simple variations of the chain lengths the temperature range in which the nematic mesophase is present could be tuned. The described approach offers the possibility of covalent incorporation of the mesogens into polymers via olefin metathesis techniques, resulting in enlarged stability of the mesophase. Monomers and polymers could be easily aligned on rubbed polyimide substrates as revealed by polarised absorption spectroscopy. [source]


Effects of uniaxial stress on the magnetic properties of thin films and GMR sensors prepared on polyimide substrates

PHYSICA STATUS SOLIDI (A) APPLICATIONS AND MATERIALS SCIENCE, Issue 8 2008
Berkem Özkaya
Abstract The effects of externally applied uniaxial stress on the magnetic properties of Co thin films and pseudo-spin-valve (PSV) structures on flexible polyimide substrates were investigated. The advantage of the polyimide substrate is its flexibility and high elasticity (,1%), which cannot be achieved using conventional crystalline substrates. The Co layers exhibit a macroscopic easy axis induced by the preparation process. When the stress is applied perpendicular to the induced in-plane easy axis, the magnetic domains in the film rotate towards the applied stress direction, which was confirmed using Kerr microscopy and magneto-optical Kerr effect (MOKE) magnetometer measurements. A Co/Cu/Ni PSV system was prepared on polyimide substrate with dc magnetron sputtering. Applying uniaxial stress leads to opposite rotation of the magnetisation directions in both layers to each other due to different signs of the magnetostriction coefficients of Co and Ni. The magnetisation and giant magnetoresistance (GMR) curves under applied stress were recorded using in situ MOKE and current in-plane four-point probe techniques, respectively. When the stress is applied perpendicular to the external magnetic field (Hext), the operating range of the GMR sensor increases, whereas the sensitivity decreases. Anisotropy energies and saturation magnetostriction values of the Co and Ni layer were determined by fitting the GMR and magnetisation curves using a micromagnetic model. (© 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim) [source]