PQ Interval (pq + interval)

Distribution by Scientific Domains


Selected Abstracts


AAIR Versus DDDR Pacing in the Bradycardia Tachycardia Syndrome: A Prospective, Randomized, Double-blind, Crossover Trial

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 11 2001
BERNHARD SCHWAAB
SCHWABB, B., et al.: AAIR Versus DDDR Pacing in the Bradycardia Tachycardia Syndrome: A Prospective, Randomized, Double-blind, Crossover Trial. In 19 patients paced and medicated for bradycardia tachycardia syndrome (BTS), AAIR and DDDR pacing were compared with regard to quality of life (QoL), atrial tachyarrhythmia (AFib), exercise tolerance, and left ventricular (LV) function. Patients had a PQ interval , 240 ms during sinus rhythm, no second or third degree AV block, no bundle branch block, or bifascicular block. In DDDR mode, AV delay was optimized using the aortic time velocity integral. After 3 months, QoL was assessed by questionnaires, patients were investigated by 24-hour Holter, cardiopulmonary exercise testing (CPX) was performed, and LV function was determined by echocardiography. QoL was similar in all dimensions, except dizziness, showing a significantly lower prevalence in AAIR mode. The incidence of AFib was 12 episodes in 2 patients with AAIR versus 22 episodes in 7 patients with DDDR pacing (P = 0.072). In AAIR mode, 164 events of second and third degree AV block were detected in 7 patients (37%) with pauses between 1 and 4 seconds. During CPX, exercise duration and work load were higher in AAIR than in DDDR mode (423 ± 127 vs 402 ± 102 s and 103 ± 31 vs 96 ± 27 Watt, P < 0.05). Oxygen consumption (VO2), was similar in both modes. During echocardiography, only deceleration of early diastolic flow velocity and early diastolic closure rate of the anterior mitral valve leaflet were higher in DDD than in AAI pacing (5.16 ± 1.35 vs 3.56 ± 0.95 m/s2 and 69.2 ± 23 vs 54.1 ± 26 mm/s, P < 0.05). As preferred pacing mode, 11 patients chose DDDR, 8 patients chose AAIR. Hence, AAIR and DDDR pacing seem to be equally effective in BTS patients. In view of a considerable rate of high degree AV block during AAIR pacing, DDDR mode should be preferred for safety reasons. [source]


Detailed ECG Analysis of Atrial Repolarization in Humans

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 1 2009
Fredrik Holmqvist M.D., Ph.D.
Introduction: Data on human atrial repolarization are scarce since the QRS complex normally obscures its ECG trace. In the present study, consecutive patients with third-degree AV block were studied to better describe the human Ta wave. Methods and Results: Forty patients (mean age 75 years, 17 men) were included. All anti-arrhythmic drugs were discontinued before ECG recording. Standard 12-lead ECGs were recorded, transformed to orthogonal leads and studied using signal-averaged P wave analysis. The average P wave duration was 124 ± 16 ms. The PTa duration was 449 ± 55 ms (corrected PTa 512 ± 60 ms) and the Ta duration (P wave end to Ta wave end) was 323 ± 56 ms. The polarity of the Ta wave was opposite to that of the P wave in all leads. The Ta peaks were located at 196 ± 55 ms in Lead Y, 216 ± 50 ms in Lead X, and 335 ± 92 in Lead Z. No correlation was found between P wave duration and Ta duration, or between Ta peak amplitude and Ta duration. The morphology of the Ta wave was similar regardless of the interatrial conduction. Conclusions: The Ta wave has the opposite polarity, and the duration is generally two to three times that, of the P wave. Although the Ta peak may occasionally be located in the PQ interval during normal AV conduction, it is unlikely that enough information can be obtained from analysis of this segment to differentiate normal from abnormal atrial repolarization. Hence, an algorithm for QRST cancellation during sinus rhythm is needed to further improve analysis. [source]


Cardiac function and antiepileptic drug treatment in the elderly: A comparison between lamotrigine and sustained-release carbamazepine

EPILEPSIA, Issue 8 2009
Erik Saetre
Summary Purpose:, To investigate the comparative effects of carbamazepine (CBZ) and lamotrigine (LTG) on electrocardiography (ECG) parameters in elderly patients with newly diagnosed epilepsy. Methods:,, The study was conducted in the Norwegian subcohort (n = 108) of an international randomized double-blind 40-week trial, which compared the efficacy and tolerability of LTG and sustained-release CBZ in patients aged 65 and older with newly diagnosed epilepsy. Target maintenance doses were 400 mg/day for CBZ and 100 mg/day for LTG, with adjustments based on clinical response. Patients with significant unpaced atrioventricular (AV) conduction defect were excluded. Resting 12-lead ECG recordings were made under standardized conditions at pretreatment (baseline) and at the 40-week study visit (treatment visit). Changes in QRS interval (primary endpoint), heart rate (HR), PQ, and QTc (HR-corrected QT) intervals were assessed and compared between groups. Results:, Of the 108 patients randomized, 33 discontinued prematurely because of adverse events (n = 24, none of which was cardiac) or other reasons (n = 9), and 15 were nonevaluable due to incomplete ECG data. None of the assessed ECG parameters differed significantly between groups at baseline. No significant ECG changes were recorded between baseline and treatment visit for QRS duration and QTc intervals, whereas HR fell and PQ intervals increased slightly on both treatments. However, there were no differences between groups in changes from baseline to treatment visit. There were no significant relationships between individual ECG changes and serum drug concentrations, except for QTc intervals, which decreased slightly with increasing CBZ concentrations. The proportion of patients with ECG parameters outside the normal range at treatment visit was similar to that recorded at baseline. Discussion:, Clinically significant ECG changes are not common during treatment with CBZ or LTG in elderly patients with no preexisting significant AV conduction defects. [source]


Computer-Based Analysis of Dynamic QT Changes: Toward High Precision and Individual Rate Correction

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 4 2002
Corina Dota M.D.
Background: New strategies are needed to improve the results of automatic measurement of the various parts of the ECG signal and their dynamic changes. Methods: The EClysis software processes digitally-recorded ECGs from up to 12 leads at 500 Hz, using strictly defined algorithms to detect the PQRSTU points and to measure ECG intervals and amplitudes. Calculations are made on the averaged curve of each sampling period (beat group) or as means ± SD for beat groups, after being analyzed at the individual beat level in each lead. Resulting data sets can be exported for further statistical analyses. Using QT and R-R measured on beat level, an individual correction for the R-R dependence can be performed. Results: EClysis assigns PQRSTU points and intervals in a sensitive and highly reproducible manner, with coefficients of variation in ECG intervals corresponding to ca. 2 ms in the simulated ECG. In the normal ECG, the CVs are 2% for QRS, 0.8% for QT, and almost 6% for PQ intervals. EClysis highlights the increase in QT intervals and the decrease of T-wave amplitudes during almokalant infusion versus placebo. Using the observed linear or exponential relationships to adjust QT for R-R dependence in healthy subjects, one can eliminate this dependence almost completely by individualized correction. Conclusions: The EClysis system provides a precise and reproducible method to analyze ECGs. A.N.E. 2002;7(4):289,301 [source]