Output Monitor (output + monitor)

Distribution by Scientific Domains

Kinds of Output Monitor

  • cardiac output monitor


  • Selected Abstracts


    Search for a non-invasive cardiac output monitor

    EMERGENCY MEDICINE AUSTRALASIA, Issue 3 2008
    Ogilvie Thom
    No abstract is available for this article. [source]


    Reply: Validation of a new cardiac output monitor

    LIVER TRANSPLANTATION, Issue 11 2009
    Peter Nissen
    [source]


    Reliability of a new ultrasonic cardiac output monitor in recipients of living donor liver transplantation,,§¶

    LIVER TRANSPLANTATION, Issue 7 2008
    Bai-Chuan Su
    The ultrasonic cardiac output monitor (USCOM) is a new Doppler device for noninvasive hemodynamic monitoring. The aim of this prospective nonrandomized study was to test the feasibility, perioperative reliability, and clinical applicability of using USCOM as an alternative to pulmonary artery catheterization in recipients of living donor liver transplantation. Thirteen patients scheduled to receive living donor liver transplants were initially recruited. Three were subsequently excluded prior to the commencement of surgery because of technical difficulties in obtaining diagnostic-quality images with USCOM. Ten patients proceeded to be studied. Cardiac output measurements by thermodilution and USCOM were compared at 30-minute intervals throughout the procedure and at 10 specific procedural reference points during the surgery when hemodynamic changes were most likely to be observed. The data were analyzed with Lin's concordance coefficient and Bland-Altman analysis. Two hundred ninety paired cardiac output values were obtained from the 10 patients. The concordance between both methods was excellent in 8 patients and satisfactory in 2. Bland-Altman analysis of all data produced a mean bias of , 0.02 L/minute for USCOM, and the 95% limits of agreement were ,1.06 to +1.10 L/minute. Further analysis of the 10 reference time points showed minimal bias and high levels of agreement between the methods. We conclude that USCOM provides an accurate and noninvasive method for cardiac output measurement during liver transplantation. It may therefore represent an alternative to pulmonary artery catheter placement with consequent reduction in patient's risk and morbidity associated with catheterization. Liver Transpl 14:1029,1037, 2008. © 2008 AASLD. [source]


    Comparison of the USCOM ultrasound cardiac output monitor with pulmonary artery catheter thermodilution in patients undergoing liver transplantation,

    LIVER TRANSPLANTATION, Issue 7 2008
    Lai-Sze Grace Wong
    The aim of the study was to compare the standard technique of cardiac output determination by pulmonary artery catheter thermodilution (PAC-TD) with a noninvasive ultrasound Doppler monitor (USCOM Pty., Ltd., Coffs Harbour, Australia) in surgery for liver transplantation. We wished to determine if the degree of accuracy would allow the ultrasound cardiac output monitor (USCOM) to be used as an alternative monitor in a clinical setting in which wide fluctuations in cardiac output could be expected. This was a prospective method comparison study, with 71 paired measurements obtained in 12 patients undergoing liver transplantation in a university teaching hospital. Bland-Altman analysis of the 2 techniques showed a bias of 0.39 L/minute, with the USCOM cardiac output lower compared with that of PAC-TD. The bias was small and did not vary with the magnitude of the cardiac output. The 95% limits of agreement were ,1.47 and 2.25 L/minute. There was good repeatability for USCOM measurements, with a repeatability coefficient of 0.43 for USCOM versus 0.77 for PAC-TD. We conclude that USCOM is acceptable for the clinical determination of noninvasive cardiac output, particularly in situations in which tracking changes over time is more important than knowing the precise value. However, the utility of USCOM is limited by its inability to measure pulmonary artery pressure. Liver Transpl 14:1038,1043, 2008. © 2008 AASLD. [source]


    Measurement of cardiac output in normal pregnancy by a non-invasive two-dimensional independent Doppler device

    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OBSTETRICS AND GYNAECOLOGY, Issue 2 2009
    Catharina C. M. KAGER
    Aims: To compose a normogram regarding cardiac output during pregnancy measured with ultrasonic cardiac output monitor (USCOM), a non-expensive simple continuous wave Doppler device and to investigate if this machine could be useful for haemodynamic monitoring during pregnancy. Methods: Cardiac output was measured in 172 pregnant women with a gestational age < 21 weeks (n = 59), 21,32 weeks (n = 48), and > 32 weeks' gestation (n = 48). Interobserver differences were determined by measuring 24 patients and comparing results between three different observers. Results: A good signal could be obtained in 155 (90.2%) pregnant women. Haemodynamic profiles were in line with data published in the literature. In 9.8 % of cases it was difficult to get a good result. Interobserver variations between the research officer (CK) and two clinicians were good (r = 0.9359 and r = 0.9609). Conclusion: USCOM appears to be a reliable and fast method to measure cardiac output compared with existing highly complex ultrasounds machines used in cardiology. It is easy to learn, cheap and quite reproducible between different observers. Further research is required to define its place in the management of hypertensive complications during pregnancy. [source]