Home About us Contact | |||
New Supraglottic Airway Device (new + supraglottic_airway_device)
Selected AbstractsRandomized comparison of the SLIPA (Streamlined Liner of the Pharynx Airway) and the SS-LM (Soft Seal Laryngeal Mask) by medical studentsEMERGENCY MEDICINE AUSTRALASIA, Issue 5-6 2006Cindy Hein Abstract Objective:, The aim of the study was to compare the Streamlined Liner of the Pharynx Airway (SLIPA; Hudson RCI), a new supraglottic airway device, with the Soft Seal Laryngeal Mask (SS-LM; Portex) when used by novices. Methods:, Thirty-six medical students with no previous airway experience, received manikin training in the use of the SLIPA and the SS-LM. Once proficient, the students inserted each device in randomized sequence, in two separate patients in the operating theatre. Only two insertion attempts per patient were allowed. Students were assessed in terms of: device preference; success or failure; success at first attempt and time to ventilation. Results:, Sixty-seven per cent of the students preferred to use the SLIPA (95% confidence interval 49,81%). The SLIPA was successfully inserted (one or two attempts) in 94% of patients (34/36) and the SS-LM in 89% (32/36) (P = 0.39). First attempt success rates were 83% (30/36) and 67% (24/36) in the SLIPA and SS-LM, respectively (P = 0.10). Median time to ventilation was shorter with the SLIPA (40.6 s) than with the SS-LM (66.9 s) when it was the first device used (P = 0.004), but times were similar when inserting the second device (43.8 s vs 42.9 s) (P = 0.75). Conclusions:, In the present study novice users demonstrated high success rates with both devices. The SLIPA group achieved shorter times to ventilation when it was the first device they inserted, which might prove to be of clinical significance, particularly in resuscitation attempts. Although the Laryngeal Mask has gained wide recognition for use by both novice users and as a rescue airway in failed intubation, the data presented here suggest that the SLIPA might also prove useful in these areas. [source] A new supraglottic airway device: LMA-SupremeÔ, comparison with LMA-ProsealÔACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 7 2009T. HOSTEN Background and objective: The LMA-SupremeÔ (S-LMAÔ) is a new supraglottic airway device that presents combined features of flexibility, curved structure and single use and a different cuff structure. The purpose of this study was to compare the oropharyngeal leak pressures (OLP) of LMA-ProsealÔ (P-LMAÔ) and S-LMAÔ. Methods: Sixty adult patients were prospectively and randomly allocated to undergo insertion of P-LMAÔ (n=30) or S-LMAÔ (n=30). The cuffs were inflated until the intracuff pressure (ICP) reached 60 cm H2O. Orogastric leak pressures, insertion times, first attempt success rates, fiberoptical assessment of position, cuff pressures, orogastric tube (OGT) placement and OGT insertion times were compared. Unblinded observers collected intraoperative data and blinded observers collected post-operative data. Results: The first insertion attempts and time taken to provide an effective airway were similar between the groups. Two patients (P-LMAÔ, n=1; S-LMAÔ, n=1) were intubated due to excessive oropharyngeal leak and in one patient (P-LMAÔ, n=1) due to failed OGT placement. OLPs were similar (P-LMAÔ; 26.9±6.6 S-LMAÔ; 26.1±5.2). ICP increased significantly in the P-LMAÔ at the 30 and 60 min during anesthesia (P-LMAÔ; 80.1±12.8, 92.9±14.4, S-LMAÔ; 68.3±10.9, 73.7±15.6). OGT placement was successful in all patients in the S-LMAÔ, but failed in five patients in the P-LMAÔ (P=0.02). Fiberoptically determined anatomic position was better with the P-LMAÔ (P=0.03). Conclusion: Our findings suggest that S-LMAÔ had leak pressures similar to the P-LMAÔ, and this new airway device proved to be successful during both spontaneous and positive pressure ventilation. [source] Insertion characteristics, sealing pressure and fiberoptic positioning of CobraPLA in childrenPEDIATRIC ANESTHESIA, Issue 10 2007MAURIZIO PASSARIELLO MD Summary Background:, The CobraPLATM is a new supraglottic airway device designed for the use in spontaneously breathing and mechanically ventilated patients. In adults it has been found as effective as the LMA, but with better sealing qualities. The aim of the present study was to evaluate fit and sealing characteristics of CobraPLA size 1.5 and 2 in mechanically ventilated children. Methods:, Forty children, ASA I/II, aged 1,10 years, weighing 10,35 kg were scheduled for minor surgical procedures. The number of attempts for insertion and fiberoptic positioning of the CobraPLA was assessed. After muscle relaxation had been achieved, airway sealing pressure was measured by gradually increasing maximum inspiratory pressure to a maximum of 30 cmH2O. Results:, Insertion of CobraPLA was successful at the first attempt in 90% of patients. The vocal cords were visualized in 90% of patients (grade 0: 2.5%, grade 1: 7.5%, grade 2: 30%, grade 3: 15%, grade 4: 45%). Median sealing pressure was 20.0 ± 6.0 cmH2O. In 21% of patients gastric insufflation was observed at a peak inspiratory pressure of 20 cmH2O or below. Conclusions:, The CobraPLA was found to have easy insertion characteristics and good anatomical fitting in children between 10 and 35 kg. If positive pressure ventilation with CobraPLA size 1.5 and 2.0 is required, peak inspiratory pressure should be kept below the leak pressure and the abdomen closely monitored for signs of gastric insufflation. [source] |