Native Arteries (native + artery)

Distribution by Scientific Domains


Selected Abstracts


Evaluation of the Hemodynamics of a Tissue-engineered Hybrid Graft

ARTIFICIAL ORGANS, Issue 1 2010
Kuk Hui Son
Abstract We evaluated the hemodynamics of tissue-engineered hybrid graft in vivo. The hybrid expanded polytetrafluoroethylene (ePTFE) scaffold was fabricated by coating the ePTFE graft with poly (lactide-co-glycolide) (PLGA) solution. This scaffold was turned into an engineered hybrid graft by culturing smooth muscle cells on its surface. Both the ePTFE (n = 6) and the engineered hybrid grafts (n = 8) were implanted in the carotid arteries of mongrel dogs. The length of intima in the engineered hybrid graft was greater than the ePTFE. The neoarterial thickness in the engineered hybrid group was greater, and the foreign body reaction was more severe. We compared the hemodynamics (diameter, flow rate, pulsatile index, mean velocity, shear stress, resistance index, and systolic/diastolic ratio) of the native arteries in the distal anastmosis. The shear rate in the engineered hybrid group was higher immediately after implantation, and the resistance index was lower, but there was no significant difference after 4 weeks. The engineered grafts demonstrated similar hemodynamics with the ePTFE grafts after 4 weeks implantation. [source]


Preservation of Muscular and Elastic Artery Distensibility After an Intercontinental Cryoconserved Exchange: Theoretical Advances in Arterial Homograft Generation and Utilization

ARTIFICIAL ORGANS, Issue 8 2009
Daniel Bia
Abstract While the situation of tissue donation and transplantation differs between Latin American and European countries, a common problem is tissue deficiency. Hence, at present, there is a pressing need to generate alternatives so as to increase the possibilities of obtaining the requested materials. Consequently, it would be of significant interest to establish an intercontinental network for tissue exchange, to improve international cooperation, and to help patients that need tissue transplantation, and to evaluate the feasibility of using an intercontinental network for the exchange of cryopreserved arteries (cryografts), preserving the arterial distensibility and ensuring a reduced native artery,cryograft biomechanical mismatch. Distensibility was studied in ovine arteries divided into three groups: intact (in vivo tests, conscious animals), fresh control (in vitro tests immediately after the artery excision, Uruguay), and cryografts (in vitro tests of cryopreserved-transported-defrosted arteries, Spain). Histological studies were performed so as to analyze changes in the endothelial layer and elastic components. The comparison between fresh control and cryografts showed that neither the cryopreservation nor the exchange network impaired the distensibility, despite the expected histological changes found in the cryografts. The comparison between intact and cryografts showed that the cryografts would be capable of ensuring a reduced biomechanical mismatch. The cryopreservation and the intercontinental network designed for artery exchange preserved the arterial distensibility. It could be possible to transfer cryografts between Latin America and Europe to be used in cardiovascular surgeries and/or for tissue banking reprocessing, with basic biomechanical properties similar to those of the fresh and/or native arteries. [source]


A biomimetic tubular scaffold with spatially designed nanofibers of protein/PDS® bio-blends,

BIOTECHNOLOGY & BIOENGINEERING, Issue 5 2009
Vinoy Thomas
Abstract Electrospun tubular conduit (4,mm inner diameter) based on blends of polydioxanone (PDS II®) and proteins such as gelatin and elastin having a spatially designed trilayer structure was prepared for arterial scaffolds. SEM analysis of scaffolds showed random nanofibrous morphology and well-interconnected pore network. Due to protein blending, the fiber diameter was reduced from 800,950,nm range to 300,500,nm range. Fourier-transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) results confirmed the blended composition and crystallinity of fibers. Pure PDS scaffold under hydrated state exhibited a tensile strength of 5.61,±,0.42,MPa and a modulus of 17.11,±,1.13,MPa with a failure strain of 216.7,±,13%. The blending of PDS with elastin and gelatin has decreased the tensile properties. A trilayer tubular scaffold was fabricated by sequential electrospinning of blends of elastin/gelatin, PDS/elastin/gelatin, and PDS/gelatin (EG/PEG/PG) to mimic the complex matrix structure of native arteries. Under hydrated state, the trilayer conduit exhibited tensile properties (tensile strength of 1.77,±,0.2,MPa and elastic modulus of 5.74,±,3,MPa with a failure strain of 75.08,±,10%) comparable to those of native arteries. In vitro degradation studies for up to 30 days showed about 40% mass loss and increase in crystallinity due to the removal of proteins and "cleavage-induced crystallization" of PDS. Biotechnol. Bioeng. 2009; 104: 1025,1033. © 2009 Wiley Periodicals, Inc. [source]


Preservation of Muscular and Elastic Artery Distensibility After an Intercontinental Cryoconserved Exchange: Theoretical Advances in Arterial Homograft Generation and Utilization

ARTIFICIAL ORGANS, Issue 8 2009
Daniel Bia
Abstract While the situation of tissue donation and transplantation differs between Latin American and European countries, a common problem is tissue deficiency. Hence, at present, there is a pressing need to generate alternatives so as to increase the possibilities of obtaining the requested materials. Consequently, it would be of significant interest to establish an intercontinental network for tissue exchange, to improve international cooperation, and to help patients that need tissue transplantation, and to evaluate the feasibility of using an intercontinental network for the exchange of cryopreserved arteries (cryografts), preserving the arterial distensibility and ensuring a reduced native artery,cryograft biomechanical mismatch. Distensibility was studied in ovine arteries divided into three groups: intact (in vivo tests, conscious animals), fresh control (in vitro tests immediately after the artery excision, Uruguay), and cryografts (in vitro tests of cryopreserved-transported-defrosted arteries, Spain). Histological studies were performed so as to analyze changes in the endothelial layer and elastic components. The comparison between fresh control and cryografts showed that neither the cryopreservation nor the exchange network impaired the distensibility, despite the expected histological changes found in the cryografts. The comparison between intact and cryografts showed that the cryografts would be capable of ensuring a reduced biomechanical mismatch. The cryopreservation and the intercontinental network designed for artery exchange preserved the arterial distensibility. It could be possible to transfer cryografts between Latin America and Europe to be used in cardiovascular surgeries and/or for tissue banking reprocessing, with basic biomechanical properties similar to those of the fresh and/or native arteries. [source]


Compliance properties of conduits used in vascular reconstruction,

BRITISH JOURNAL OF SURGERY (NOW INCLUDES EUROPEAN JOURNAL OF SURGERY), Issue 11 2000
N. R. Tai
Background Compliance mismatch between native artery and prosthetic graft used for infrainguinal bypass is implicated in the aetiology of graft failure. The aim was to quantify the elastic properties of a new compliant poly(carbonate)polyurethane (CPU) vascular graft, and to compare the compliance properties of grafts made from CPU, expanded polytetrafluoroethylene (ePTFE), Dacron and human saphenous vein with that of human muscular artery. Methods A pulsatile flow phantom was used to perfuse vessel and prosthetic graft segments at physiological pulse pressure and flow. Intraluminal pressure was measured using a Millar Mikro-tip catheter transducer and vessel wall motion was determined with duplex ultrasonography using an echo-locked wall-tracking system. Diametrical compliance and a stiffness index were then calculated for each type of conduit over mean pressures ranging from 30 to 100 mmHg by 10-mmHg increments. Results The compliance values of CPU and artery (mean over the pressure range) were similar (mean(s.d.) 8·1(0·4) and 8·0(5·9) per cent per mmHg × 10,2 respectively), although the elastic behaviour of artery was anisotropic unlike CPU, which was isotropic. Dacron and ePTFE grafts had lower compliance values (1·8(1·2) and 1·2(0·3) per cent per mmHg × 10,2 respectively, averaged over the pressure range). In both these cases, compliance and stiffness differed significantly from that of artery over a mean pressure range of 30,90 mmHg. Human saphenous vein exhibited anisotropic behaviour and, although compliant at low pressure (30 mmHg), was markedly incompliant at higher pressures. Conclusion Compliant polyurethane grafts offer a greater degree of compliance match than either ePTFE or Dacron. © 2000 British Journal of Surgery Society Ltd [source]