Home About us Contact | |||
Multiparametric Flow Cytometry (multiparametric + flow_cytometry)
Selected AbstractsDetection of tumor cells in body cavity fluids by flow cytometric and immunocytochemical analysisDIAGNOSTIC CYTOPATHOLOGY, Issue 8 2006Awtar Krishan Ph.D. Abstract Measurement of electronic volume versus DNA content of nuclei can be used to discriminate between normal and malignant cells. Epithelial membrane antigen immunocytochemistry (EMA-ICC), a helpful ancillary test in body cavity fluids, is not universally accurate for detecting malignancy in effusions. The current study was undertaken to determine if multiparametric flow cytometry (based on simultaneous analysis of light scatter, nuclear volume, DNA, and nuclear protein content) in combination with (EMA-ICC) could be used for the detection of malignant cells in peritoneal and pleural fluids. We studied 130 body cavity fluids (68 peritoneal and 62 pleural fluids) by conventional cytology and multiparametric laser flow cytometry. EMA-ICC was performed using EMA antibodies and L-SAB detection system (DakoCytomation, Carpinteria, CA). EMA-ICC had significantly higher sensitivity than conventional cytology (79% versus 59%, P = 0.016) and ploidy (79% versus 38%, P = 0.001). Cytology had significantly higher specificity than ploidy (97% versus 82%, P = 0.012). The differences in specificity between EMA-ICC and ploidy (87% versus 82%, P= 0.607) or EMA-ICC and cytology (87% versus 97%, P = 0.109) were not statistically significant. However, assuming serial testing, sensitivity increased significantly for the combinations of cytology and EMA-ICC (79.4%, P = 0.016) and cytology and ploidy (73.5%, P = 0.004) as compared to cytology alone (58.8%). Also, the combination of cytology and ploidy had a higher sensitivity than ploidy alone (73% versus 38%, P < 0.0001). However, the sensitivity associated with the three tests used in serial (85.3%) was not significantly different from the sensitivities corresponding to the combination of cytology and EMA-ICC (79%) or cytology and ploidy (73%). Multiparametric flow cytometry utilizing high resolution DNA, nuclear volume, protein measurement, and ICC, in combination with cytomorphology, may be a valuable tool for rapid identification of malignant cells in body cavity fluids. Diagn. Cytopathol. 2006;34:528,541. © 2006 Wiley-Liss, Inc. [source] Prednisone induces immunophenotypic modulation of CD10 and CD34 in nonapoptotic B-cell precursor acute lymphoblastic leukemia cells,CYTOMETRY, Issue 3 2008Giuseppe Gaipa Abstract Background: Immunophenotypic modulation is induced by steroids in pediatric B-cell precursor acute lymphoblastic leukemia (BCP-ALL) patients during remission induction therapy. Methods: We cultured BCP-ALL blasts from diagnostic bone marrow (BM) samples (n = 20) in the presence of prednisone on stroma layer obtained from BM-derived mesenchymal cells to maintain viability. Antigen expression was assessed by multiparametric flow cytometry. Results: Leukemia samples that sustained the treatment in vitro with prednisone, showed significative reduction of CD10 and CD34 expression compared with control, and it was comparable with that observed in residual leukemic cells of the same patients in BM at day 15 of treatment. Modulated cells were viable as determined by Annexin V staining and preserved light scattering properties. Of note, the extent of antigen modulation in vitro correlated with response to prednisone in vivo. Conclusions: The prednisone-induced immunophenotypic modulation can be reproduced in vitro and this phenomenon may reflect sensitivity to chemotherapy. © 2008 Clinical Cytometry Society [source] Peripheral blood MDS score: A new flow cytometric tool for the diagnosis of myelodysplastic syndromes,CYTOMETRY, Issue 1 2005Sindhu Cherian Abstract Background Myelodysplastic syndromes (MDS) are a heterogeneous group of hematopoietic disorders diagnosed using morphologic and clinical findings supported by cytogenetics. Because abnormalities may be subtle, diagnosis using these approaches can be challenging. Flow cytometric (FCM) approaches have been described; however the value of bone marrow immunophenotyping in MDS remains unclear due to the variability in detected abnormalities. We sought to refine the FCM approach by using peripheral blood (PB) to create a clinically useful tool for the diagnosis of MDS. Methods PB from 15 patients with MDS was analyzed by multiparametric flow cytometry using an extensive panel of monoclonal antibodies. Patterns of neutrophil antigen expression were compared with those of normal controls (n = 16) to establish light scatter and/or immunophenotypic abnormalities that correlated with MDS. A scoring algorithm was developed and validated prospectively on a blinded patient set. Results PB neutrophils from patients with MDS had lower side scatter and higher expression of CD66 and CD11a than did controls. Some MDS PB neutrophils demonstrated abnormal CD116 and CD10 expression. Because none of these abnormalities proved consistently diagnostic, we sought to increase the power of the assay by devising a scoring system to allow the association of multiple abnormalities and account for phenotypic variations. The PB MDS score differentiated patients with MDS from controls (P < 0.0001) in the test set. In a prospective validation, the PB MDS score successfully identified patients with MDS (sensitivity 73%, specificity 90%). Conclusions FCM analysis of side scatter and only four additional immunophenotypic parameters of PB neutrophils using the PB MDS score proved more sensitive than standard laboratory approaches and may provide an additional, more reliable diagnostic tool in the identification of MDS. © 2005 Wiley-Liss, Inc. [source] Detection of tumor cells in body cavity fluids by flow cytometric and immunocytochemical analysisDIAGNOSTIC CYTOPATHOLOGY, Issue 8 2006Awtar Krishan Ph.D. Abstract Measurement of electronic volume versus DNA content of nuclei can be used to discriminate between normal and malignant cells. Epithelial membrane antigen immunocytochemistry (EMA-ICC), a helpful ancillary test in body cavity fluids, is not universally accurate for detecting malignancy in effusions. The current study was undertaken to determine if multiparametric flow cytometry (based on simultaneous analysis of light scatter, nuclear volume, DNA, and nuclear protein content) in combination with (EMA-ICC) could be used for the detection of malignant cells in peritoneal and pleural fluids. We studied 130 body cavity fluids (68 peritoneal and 62 pleural fluids) by conventional cytology and multiparametric laser flow cytometry. EMA-ICC was performed using EMA antibodies and L-SAB detection system (DakoCytomation, Carpinteria, CA). EMA-ICC had significantly higher sensitivity than conventional cytology (79% versus 59%, P = 0.016) and ploidy (79% versus 38%, P = 0.001). Cytology had significantly higher specificity than ploidy (97% versus 82%, P = 0.012). The differences in specificity between EMA-ICC and ploidy (87% versus 82%, P= 0.607) or EMA-ICC and cytology (87% versus 97%, P = 0.109) were not statistically significant. However, assuming serial testing, sensitivity increased significantly for the combinations of cytology and EMA-ICC (79.4%, P = 0.016) and cytology and ploidy (73.5%, P = 0.004) as compared to cytology alone (58.8%). Also, the combination of cytology and ploidy had a higher sensitivity than ploidy alone (73% versus 38%, P < 0.0001). However, the sensitivity associated with the three tests used in serial (85.3%) was not significantly different from the sensitivities corresponding to the combination of cytology and EMA-ICC (79%) or cytology and ploidy (73%). Multiparametric flow cytometry utilizing high resolution DNA, nuclear volume, protein measurement, and ICC, in combination with cytomorphology, may be a valuable tool for rapid identification of malignant cells in body cavity fluids. Diagn. Cytopathol. 2006;34:528,541. © 2006 Wiley-Liss, Inc. [source] Minimal residual disease monitoring after allogeneic transplantation may help to individualize post-transplant therapeutic strategies in acute myeloid malignancies,AMERICAN JOURNAL OF HEMATOLOGY, Issue 3 2009María Díez-Campelo This study evaluates the prognostic value of minimal residual disease (MRD) monitoring by multiparametric flow cytometry in 41 patients with acute myeloid leukemia or myelodysplastic syndrome undergoing allogeneic transplantation. MRD assessment after transplant (day +100) allowed to discriminate different risk populations, being the most significant cut-off value for outcome level of MRD ,10,3. Outcome was significantly better among patients with low (<10,3) versus high (,10,3) MRD at day +100 after transplant. Thus, overall survival was 73% versus 25% at 4 years among patients with low versus high MRD at day +100 after transplant (P = 0.002); 74% of patients with low MRD were event free at 4 years as compared to 17% among patients with high MRD (P = 0.01). In multivariate analysis, MRD value as well as chronic GVHD significantly influenced outcome. In conclusion, MRD monitoring early post-transplant is an important tool for outcome prediction and should be considered in decision making after allogeneic transplantation. Am. J. Hematol. 2009. © 2008 Wiley-Liss, Inc. [source] |