Home About us Contact | |||
Micro CT (micro + ct)
Selected AbstractsProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by micro CTINTERNATIONAL ENDODONTIC JOURNAL, Issue 2 2003O. A. Peters No abstract is available for this article. [source] Brief communication: Histology and micro CT as methods for assessment of facial suture patencyAMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, Issue 4 2009Lauren E. Reinholt Abstract The extent of fusion in facial sutures has implications for topics ranging from biomechanics to phylogeny reconstruction. An unfortunate limitation of studying sutural fusion in skeletal specimens is that it is difficult to assess whether apparently patent sutures are in fact fused internally. Both histology and microcomputed tomography (CT) are potential tools for solving this, but relatively few studies have attempted to discern the limits of micro CT for visualization of microanatomical structures. We examined microanatomical aspects of facial sutures in adult cadaveric samples from captive bushbabies. Premaxillary and nasopremaxillary sutures were examined in serially sectioned snouts of four greater bushbabies (Otolemur garnettii) and four lesser bushbabies (Galago moholi). Sections containing sutures with osseous bridging were rated as "fused," and the presence or absence of grooves on the external side was recorded. One bushbaby was studied using micro CT prior to physical sectioning. O. garnettii and two of the G. moholi show multiple foci of fusion. Histological examination confirmed that sutural fusion is limited to the internal surface in numerous sections, resulting in an external notch. Such points of internal fusion could be clearly visualized in raw CT slices. The presence of such notches suggests that external examination can underestimate the degree of suture fusion. Thus, microanatomical evidence may be needed to fully assess biomechanical correlates and phylogenetic interpretations based on fusion of facial sutures. Our results also indicate micro CT may be a useful tool to obtain this evidence. Am J Phys Anthropol 2009. © 2009 Wiley-Liss, Inc. [source] Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installationCLINICAL ORAL IMPLANTS RESEARCH, Issue 3 2007M. A. Huwiler Objectives: To monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics and during the early phases of healing and incorporation of Straumann® dental implants with an SLA surface. Material and methods: 17 Straumann 4.1 mm implants (10 mm) and 7 Straumann 4.8 mm implants (10 mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1 mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). Results: Pocket probing depths ranged from 2,4 mm and bleeding on probing from 5,20%. At baseline, BVD varied between 24% and 65% and BTC between 4.9 and 25.4 for the 4.1 mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8 mm diameter implants baseline ISQ values ranged from 57,70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2,3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1 mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. Conclusion: ISQ values of 57,70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since the decrease occurred after the fact. [source] |