Home About us Contact | |||
Membrane Fouling (membrane + fouling)
Selected AbstractsOptimization of mass transfer for toxin removal and immunoprotection of hepatocytes in a bioartificial liverBIOTECHNOLOGY & BIOENGINEERING, Issue 5 2009Geir I. Nedredal Abstract This study was designed to determine optimal operating conditions of a bioartificial liver (BAL) based on mass transfer of representative hepatotoxins and mediators of immune damage. A microprocessor-controlled BAL was used to study mass transfer between patient and cell compartments separated by a hollow fiber membrane. Membrane permeability (70, 150, or 400,kDa molecular weight cut-off,MWCO), membrane convection (high: 50,mL/min; medium: 25,mL/min; low: 10,mL/min; diffusion: 0,mL/min), and albumin concentration in the cell compartment (0.5 or 5,g%) were considered for a total of 24 test conditions. Initially, the patient compartment contained pig plasma supplemented with ammonia (0.017,kDa), unconjugated bilirubin (0.585,kDa), conjugated bilirubin (0.760,kDa), TNF-, (17,kDa), pig albumin (67,kDa), pig IgG (147,kDa), and pig IgM (900,kDa). Mass transfer of each substance was determined by its rate of appearance in the cell compartment. Membrane fouling was assessed by dextran polymer technique. Of the three tested variables (membrane pore size, convection, and albumin concentration), membrane permeability had the greatest impact on mass transfer (P,<,0.001). Mass transfer of all toxins was greatest under high convection with a 400,kDa membrane. Transfer of IgG and IgM was insignificant under all conditions. Bilirubin transfer was increased under high albumin conditions (P,=,0.055). Fouling of membranes ranged from 7% (400,kDa), 24% (150,kDa) to 62% (70,kDa) during a 2-h test interval. In conclusion, optimal toxin removal was achieved under high convection with a 400-kDa membrane, a condition which should provide adequate immunoprotection of hepatocytes in the BAL. Biotechnol. Bioeng. 2009; 104: 995,1003. © 2009 Wiley Periodicals, Inc. [source] Industrial wastewater treatment in a membrane bioreactor: A reviewENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, Issue 1 2004B. Marrot Abstract This paper provides a detailed literature review of wastewater treatment in a membrane bioreactor process (MBR) with special focus on industrial wastewater treatment. MBR systems are compared with conventional wastewater treatment systems. The characteristics of the bioreactor treatment process (biomass concentration and floc size, organic and mass loading rates, etc.) are examined. The membrane separation of microorganisms from the treated wastewater is discussed in detail. Problems of membrane fouling and membrane washing and regeneration, linked to activated sludge characteristics, are examined. © 2004 American Institute of Chemical Engineers Environ Prog, 23: 59,68, 2004 [source] Chemical modification of polyethersulfone nanofiltration membranes: A reviewJOURNAL OF APPLIED POLYMER SCIENCE, Issue 1 2009B. Van der Bruggen Abstract Polysulfone (PS) and poly(ether)sulfone (PES) are often used for synthesis of nanofiltration membranes, due to their chemical, thermal, and mechanical stability. The disadvantage for applying PS/PES is their high hydrophobicity, which increases membrane fouling. To optimize the performance of PS/PES nanofiltration membranes, membranes can be modified. An increase in membrane hydrophilicity is a good method to improve membrane performance. This article reviews chemical (and physicochemical) modification methods applied to increase the hydrophilicity of PS/PES nanofiltration membranes. Modification of poly(ether)sulfone membranes in view of increasing hydrophilicity can be carried out in several ways. Physical or chemical membrane modification processes after formation of the membrane create more hydrophilic surfaces. Such modification processes are (1) graft polymerization that chemically attaches hydrophilic monomers to the membrane surface; (2) plasma treatment, that introduces different functional groups to the membrane surface; and (3) physical preadsorption of hydrophilic components to the membrane surface. Surfactant modification, self-assembly of hydrophilic nanoparticles and membrane nitrification are also such membrane modification processes. Another approach is based on modification of polymers before membrane formation. This bulk modification implies the modification of membrane materials before membrane synthesis of the incorporation of hydrophilic additives in the membrane matrix during membrane synthesis. Sulfonation, carboxylation, and nitration are such techniques. To conclude, polymer blending also results in membranes with improved surface characteristics. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2009 [source] Test of flow field on the annular meridian plane in a tubular membrane separator with rotary tangential flowJOURNAL OF CHEMICAL TECHNOLOGY & BIOTECHNOLOGY, Issue 9 2004Cheng Duan Wang Abstract Enhancement of membrane microfiltration by rotary tangential flow is a new technique, which is based on the hydrocyclone mechanism. It improved the structure of the general membrane separator and the form of the liquid suspension flowing into the separator, so as to increase membrane fluxes and decrease membrane fouling. In our research, a tubular membrane separator with rotary tangential flow was designed for the first time. The flow field characteristics of polypropylene tubular membrane microfiltration in this tubular separator were studied systematically by means of the Particle Image Velocimetry (PIV) test. Streamlines and velocity distributions of the meridian plane of the separator under different operating parameters were obtained. The velocity distribution characteristics of rotary circular tangential flow were analyzed quantitatively with the following conclusions being obtained: (1)In the non-vortex area, no matter how the operating parameters (flux, entry pressure) change, the velocity near the rotary tangential flow entrance is higher than the velocity far from the entrance at the same radial coordinates. In the vortex area, generally the flow velocity of the inner vortex is lower than that of the outer vortex. At the vortex center, the velocity is the lowest, the radial velocity being generally equal to zero. In the vortex zone, the radial velocity is less than the axial velocity. (2)Under test conditions, the radial velocity and the axial velocity of the vortexes' borders are 1,2 times the average axial velocity in the annular gap of the membrane module. The maximum radial velocity and axial velocity of Taylor vortexes are 2,5 times the average axial velocity in the annular gap of the membrane module. (3)In the vortexes that formed on the meridian plane, it was found that mass transfer occurred between the inner and outer parts of the fluid. Much fluid moved from the outer vortexes into the inner ones, which was able to prevent particles blocking the membrane tube. Copyright © 2004 Society of Chemical Industry [source] Enhancement of ultrafiltration using gas sparging: a comparison of different membrane modules,JOURNAL OF CHEMICAL TECHNOLOGY & BIOTECHNOLOGY, Issue 2-3 2003Zhanfeng Cui Abstract Ultrafiltration is widely used in the chemical, pharmaceutical, food and water industries. Practical difficulties arise in designing and operating the process due to concentration polarisation and membrane fouling. Enhancement of ultrafiltration is highly desirable to achieve a higher permeate flux at a fixed energy input, or a reduced energy input whilst maintaining the level of permeate flux, or an improved selectivity of the membrane. One effective, simple, and economic technique used to enhance ultrafiltration is the use of gas bubbles, ie injecting gas into the feed stream to create a gas,liquid two-phase cross-flow operation. In this paper, an attempt is made to compare the effect of ,bubbling' on the ultrafiltration performance, using different membrane modules (in particular, tubular and hollow fibre membrane modules). The difference in performance can be related to the feature of two-phase flow hydrodynamics and its respective effect on mass transfer. The advantages and drawbacks of using this technique to enhance ultrafiltration are discussed. © 2003 Society of Chemical Industry [source] CLARIFICATION AND PURIFICATION OF AQUEOUS STEVIA EXTRACT USING MEMBRANE SEPARATION PROCESSJOURNAL OF FOOD PROCESS ENGINEERING, Issue 3 2009M.H.M. REIS ABSTRACT Stevia rebaudiana Bertoni is a native plant from South America and its active constituents have been considered the "sweeteners of the future."Stevia is a natural diet-sweetening source, safe to health and without calories. However, the obtained raw extract is foul smelling, bitter tasting, dark brown colored, and presents suspension matter due to organic and inorganic compounds. Therefore, further purification/clarification is essential in order to get a product of commercial quality. In this work ceramic membranes were applied in the stevia extract clarification process. The process was carried out under different membrane pore sizes and at different pressure values. The best clarification result was obtained with the membrane of 0.1 µm at 4 bar. On the other hand, the best condition for the flux was obtained with the membrane of 0.2 µm at 6 bar. The process with all the tested membranes and conditions achieved recovery of sweeteners higher than 90%. Finally, a filtration mathematical model was applied to describe the flux behavior, showing that the main fouling phenomenon during the process occurred because of the complete blocking of pores. PRACTICAL APPLICATION Stevia is the world's only all-natural sweetener with zero calories, zero carbohydrates and a zero glycemic index. However, the obtained stevia extract has a dark brown appearance, mainly because of the presence of impurities. In this work the membrane separation process was studied for stevia extract clarification and purification in order to get a product with higher commercial acceptability. The obtained results showed that total clarification and recuperation of sweeteners was almost achieved. Nonetheless, membrane fouling is an inevitable problem during membrane filtration. The mathematical analysis of the fouling occurrences showed that the complete blocking of pores is the main cause for the membrane permeability decrease. [source] Probing protein colloidal behavior in membrane-based separation processes using spectrofluorometric Rayleigh scattering dataBIOTECHNOLOGY PROGRESS, Issue 3 2010Rand Elshereef Abstract One of the primary problems in membrane-based protein separation is membrane fouling. In this study we explored the feasibility of employing Rayleigh light scattering data from fluorescence studies combined with chemometric techniques to determine whether a correlation could be established with membrane fouling phenomena. Membrane flux was measured in a dead-end UF filtration system and the effect of protein solution properties on the flux decline was systematically investigated. A variety of proteins were used as a test case in this study. In parallel, the colloidal behavior of the protein solutions was assessed by employing multiwavelength Rayleigh scattering measurements. To assess the usefulness of Rayleigh scattering measurements for probing the colloidal behavior of proteins, a protein solution of ,-lactoglobulin was used as a base-case scenario. The colloidal behavior of different ,-lactoglobulin solutions was inferred based on published data for this protein, under identical solution conditions, where techniques other than Rayleigh scattering had been used. Using this approach, good agreement was observed between scattering data and the colloidal behavior of this protein. To test the hypothesis that a high degree of aggregation will lead to increased membrane fouling, filtration data was used to find whether the Rayleigh scattering intensity correlated with permeate flux changes. It was found that for protein solutions which were stable and did not aggregate, fouling was reduced and these solutions exhibited reduced Rayleigh scattering. When the aggregation behavior of the solution was favored, significant flux declines occurred and were highly correlated with increased Rayleigh scattering. © 2010 American Institute of Chemical Engineers Biotechnol. Prog., 2010 [source] |