Rheological behavior of polymer melts in monodimensional flow through low-angle convergence and spiralling dies

ADVANCES IN POLYMER TECHNOLOGY, Issue 2 2001
L. Mascia
An experimental study was carried out to examine the rheological behavior of polymer melts in laminar flows through channels with small-angle convergences (2,3°) and spiralling walls (6°/mm along the flow direction), using an extrusion grade of low-density polyethylene. The results show that convergence is the main factor responsible for the observed deviations from steady state laminar shear flow, particularly with respect to additional pressure requirements to maintain a constant mass output. The swell ratio, calculated from the dimensions of the channel at the exit, was found to be considerably higher for flow-through converging channels. Only a small increase in swell ratio could be attributed, on the other hand, to the rotational elements of the die configuration. It is inferred that even for small angles of convergence the increased level of swelling is associated with elongational stress components, which were grouped together and denoted as the "additional stress." This was obtained from the difference between the calculated average shear stress at the wall, using the recorded pressure at the die entry, and the value of the average shear stress at the wall calculated from the shear viscosity data for the melt. © 2001 John Wiley & Sons, Inc. Adv Polym Techn 20: 99,107, 2001 [source]


Formulations generated from ethanol-based proliposomes for delivery via medical nebulizers

JOURNAL OF PHARMACY AND PHARMACOLOGY: AN INTERNATI ONAL JOURNAL OF PHARMACEUTICAL SCIENCE, Issue 7 2006
Abdelbary M. A. Elhissi
Multilamellar and oligolamellar liposomes were produced from ethanol-based soya phosphatidylcholine proliposome formulations by addition of isotonic sodium chloride or sucrose solutions. The resultant liposomes entrapped up to 62% of available salbutamol sulfate compared with only 1.23% entrapped by conventionally prepared liposomes. Formulations were aerosolized using an air-jet nebulizer (Pari LC Plus) or a vibrating-mesh nebulizer (Aeroneb Pro small mesh, Aeroneb Pro large mesh, or Omron NE U22). All vibrating-mesh nebulizers produced aerosol droplets having larger volume median diameter (VMD) and narrower size distribution than the air-jet nebulizer. The choice of liposome dispersion medium had little effect on the performance of the Pari nebulizer. However, for the Aeroneb Pro small mesh and Omron NE U22, the use of sucrose solution tended to increase droplet VMD, and reduce aerosol mass and phospholipid outputs from the nebulizers. For the Aeroneb Pro large mesh, sucrose solution increased the VMD of nebulized droplets, increased phospholipid output and produced no effect on aerosol mass output. The Omron NE U22 nebulizer produced the highest mass output (approx. 100%) regardless of formulation, and the delivery rates were much higher for the NaCl-dispersed liposomes compared with sucrose-dispersed formulation. Nebulization produced considerable loss of entrapped drug from liposomes and this was accompanied by vesicle size reduction. Drug loss tended to be less for the vibrating-mesh nebulizers than the jet nebulizer. The large aperture size mesh (8,m) Aeroneb Pro nebulizer increased the proportion of entrapped drug delivered to the lower stage of a twin impinger. This study has demonstrated that liposomes generated from proliposome formulations can be aerosolized in small droplets using air-jet or vibrating-mesh nebulizers. In contrast to the jet nebulizer, the performance of the vibrating-mesh nebulizers was greatly dependent on formulation. The high phospholipid output produced by the nebulizers employed suggests that both air-jet and vibrating-mesh nebulization may provide the potential of delivering liposome-entrapped or solubilized hydrophobic drugs to the airways. [source]


Cryogen spray cooling: Effects of droplet size and spray density on heat removal

LASERS IN SURGERY AND MEDICINE, Issue 2 2001
Brian M. Pikkula BS
Abstract Background and Objective Cryogen spray cooling (CSC) is an effective method to reduce or eliminate non-specific injury to the epidermis during laser treatment of various dermatological disorders. In previous CSC investigations, fuel injectors have been used to deliver the cryogen onto the skin surface. The objective of this study was to examine cryogen atomization and heat removal characteristics of various cryogen delivery devices. Study Design/Materials and Methods Various cryogen delivery device types including fuel injectors, atomizers, and a device currently used in clinical settings were investigated. Cryogen mass was measured at the delivery device output orifice. Cryogen droplet size profiling for various cryogen delivery devices was estimated by optically imaging the droplets in flight. Heat removal for various cryogen delivery devices was estimated over a range of spraying distances by temperature measurements in an skin phantom used in conjunction with an inverse heat conduction model. Results A substantial range of mass outputs were measured for the cryogen delivery devices while heat removal varied by less than a factor of two. Droplet profiling demonstrated differences in droplet size and spray density. Conclusions Results of this study show that variation in heat removal by different cryogen delivery devices is modest despite the relatively large difference in cryogen mass output and droplet size. A non-linear relationship between heat removal by various devices and droplet size and spray density was observed. Lasers Surg. Med. 28:103,112, 2001. © 2001 Wiley-Liss, Inc. [source]