MADIT II (madit + ii)

Distribution by Scientific Domains

Terms modified by MADIT II

  • madit ii patient

  • Selected Abstracts


    Obesity As a Risk Factor for Sustained Ventricular Tachyarrhythmias in MADIT II Patients

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 2 2007
    GRZEGORZ PIETRASIK M.D.
    Background: Obesity, as defined by body mass index ,30 kg/m2, has been shown to be a risk factor for cardiovascular disease. However, data on the relationship between body mass index (BMI) and the risk of ventricular arrhythmias and sudden cardiac death are limited. The aim of this study was to evaluate the risk of ventricular tachyarrhythmias and sudden death by BMI in patients after myocardial infarction with severe left ventricular dysfunction. Methods: The risk of appropriate defibrillator therapy for ventricular tachycardia or ventricular fibrillation (VT/VF) by BMI status was analyzed in 476 nondiabetic patients with left ventricular dysfunction who received an implantable cardioverter defibrillator (ICD) in the Multicenter Automatic Defibrillator Implantation Trial-II (MADIT II). Results: Mean BMI was 27 ± 5 kg/m2. Obese patients comprised 25% of the study population. After 2 years of follow-up, the cumulative rates of appropriate ICD therapy for VT/VF were 39% in obese and 24% in nonobese patients, respectively (P = 0.014). In multivariate analysis, there was a significant 64% increase in the risk for appropriate ICD therapy among obese patients as compared with nonobese patients, which was attributed mainly to an 86% increase in the risk of appropriate ICD shocks (P = 0.006). Consistent with these results, the risk of the combined endpoint of appropriate VT/VF therapy or sudden cardiac death (SCD) was also significantly increased among obese patients (Hazard Ratio 1.59; P = 0.01). Conclusions: Our findings suggest that in nondiabetic patients with ischemic left ventricular dysfunction, a BMI ,30 kg/m2 is an independent risk factor for ventricular tachyarrhythmias. [source]


    Clinical Course and Implantable Cardioverter Defibrillator Therapy in Postinfarction Women with Severe Left Ventricular Dysfunction

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 12 2005
    Ph.D. , WOJCIECH ZAREBA M.D.
    Background: There are limited data regarding implantable cardioverter defibrillator (ICD) therapy in postinfarction women with severe left ventricular dysfunction. The aim of this study was to evaluate the risk of cardiac events and effects of ICD therapy in women as compared to men enrolled in the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II). Methods and Results: Among 1,232 patients enrolled in MADIT II, there were 192 (16%) women and 1,040 (84%) men. When compared to men, women had an increased frequency of NYHA class ,II (70 vs 63%; P = 0.067), hypertension (60% vs 52%; P = 0.047), diabetes (42% vs 34%; P = 0.027), and LBBB (25% vs 17%; P = 0.011), and less frequent CABG surgery (42% vs 60%; P < 0.001). The 2-year cumulative mortality in patients randomized to conventional therapy was not significantly different in women and men (30% and 20%, respectively; P = 0.19). Adjusting for relevant clinical covariates, the hazard ratios for ICD effectiveness were similar in women (0.57; 95% CI = 0.28,1.18; P = 0.132) and men (0.66; 95% CI = 0.48,0.91; P = 0.011). The risk of appropriate ICD therapy for VT/VF was lower in women than in men (hazard ratio = 0.60 for female vs male gender; 95% CI = 0.37,0.98; P = 0.039). Conclusions: MADIT II women had similar mortality and similar ICD effectiveness when compared to men. MADIT II women with ICDs had a lower risk of arrhythmic events with fewer episodes of ventricular tachycardia than men. [source]


    The Clinical Implications of Cumulative Right Ventricular Pacing in the Multicenter Automatic Defibrillator Trial II

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 4 2005
    JONATHAN S. STEINBERG M.D.
    Introduction: This study was designed to assess whether right ventricular pacing in the implantable cardioverter defibrillator (ICD) arm of the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II was associated with an unfavorable outcome. Methods and Results: Data on the number of ventricular paced beats were available in 567 (76%) of 742 MADIT II patients with ICDs. The number of ventricular paced beats over the total number of beats showed a bimodal distribution with patients being predominantly paced or nonpaced. Therefore, patients were dichotomized at 0,50% and 51,100% of cumulative pacing with median pacing rate 0.2% and 95.6%, respectively. Endpoints included new or worsening heart failure, appropriate ICD therapy for VT/VF, and the combined endpoint of heart failure or death. Clinical features associated with frequent ventricular pacing included age ,65 years, advanced NYHA heart failure class, LVEF < 0.25, first degree AV and bundle branch block, and amiodarone use. During follow-up, 119 patients (21%) had new or worsened heart failure, 130 (23%) had new or worsened heart failure or death, and 142 (25%) had appropriate therapy for VT/VF. In comparison to patients with infrequent pacing, those with frequent pacing had significantly higher risk of new or worsened heart failure (hazard ratio = 1.93; P = 0.002) and VT/VF requiring ICD therapy (HR = 1.50; P = 0.02). Conclusions: Patients in MADIT II who were predominantly paced had a higher rate of new or worsened heart failure and were more likely to receive therapy for VT/VF. These results suggest the deleterious consequences of RV pacing, particularly in the setting of severe LV dysfunction. [source]


    Abnormal P-Wave Morphology Is a Predictor of Atrial Fibrillation Development and Cardiac Death in MADIT II Patients

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 1 2010
    Fredrik Holmqvist M.D., Ph.D.
    Background: Several ECG-based approaches have been shown to add value when risk-stratifying patients with congestive heart failure, but little attention has been paid to the prognostic value of abnormal atrial depolarization in this context. The aim of this study was to noninvasively analyze the atrial depolarization phase to identify markers associated with increased risk of mortality, deterioration of heart failure, and development of atrial fibrillation (AF) in a high-risk population with advanced congestive heart failure and a history of acute myocardial infarction. Methods: Patients included in the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) with sinus rhythm at baseline were studied (n = 802). Unfiltered and band-pass filtered signal-averaged P waves were analyzed to determine orthogonal P-wave morphology (prespecified types 1, 2, and 3/atypical), P-wave duration, and RMS20. The association between P-wave parameters and data on the clinical course and cardiac events during a mean follow-up of 20 months was analyzed. Results: P-wave duration was 139 ± 23 ms and the RMS20 was 1.9 ± 1.1 ,V. None of these parameters was significantly associated with poor cardiac outcome or AF development. After adjustment for clinical covariates, abnormal P-wave morphology was found to be independently predictive of nonsudden cardiac death (HR 2.66; 95% CI 1.41,5.04, P = 0.0027) and AF development (HR 1.75; 95% CI 1.10,2.79, P = 0.019). Conclusion: Abnormalities in P-wave morphology recorded from orthogonal leads in surface ECG are independently predictive of increased risk of nonsudden cardiac death and AF development in MADIT II patients. Ann Noninvasive Electrocardiol 2010;15(1):63,72 [source]


    Altered Interatrial Conduction Detected in MADIT II Patients Bound to Develop Atrial Fibrillation

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 3 2009
    Fredrik Holmqvist M.D., Ph.D.
    Background: Changes in P-wave morphology have recently been shown to be associated with interatrial conduction route used, without noticeable changes of P-wave duration. This study aimed at exploring the association between P-wave morphology and future atrial fibrillation (AF) development in the Multicenter Automatic Defibrillator Trial II (MADIT II) population. Methods: Patients included in MADIT-II without a history of AF with sinus rhythm at baseline who developed AF during the study ("Pre-AF") were compared to matched controls without AF development ("No-AF"). Patients were followed for a mean of 20 months. A 10-minute high-resolution bipolar ECG recording was obtained at baseline. Signal-averaged P waves were analyzed to determine orthogonal P-wave morphology, P-wave duration, and RMS20. The P-wave morphology was subsequently classified into one of three predefined types using an automated algorithm. Results: Thirty patients (age 68 ± 7 years) who developed AF during MADIT-II were compared with 60 patients (age 68 ± 8 years) who did not. P-wave duration and RMS20 in the Pre-AF group was not significantly different from the No-AF group (143 ± 21 vs 139 ± 30 ms, P = 0.26, and 2.0 ± 1.3 vs 2.1 ± 1.0 ,V, P = 0.90). The distribution of P-wave morphologies was shifted away from Type 1 in the Pre-AF group when compared to the No-AF group (Type 1/2/3/atypical; 25/60/0/15% vs 10/63/10/17%, P = 0.04). Conclusions: This study is the first to describe changes in P-wave morphology in patients prior to AF development. The results indicate that abnormal interatrial conduction may play a role in AF development in patients with prior myocardial infarction and congestive heart failure. [source]