Maze Procedure (maze + procedure)

Distribution by Scientific Domains


Selected Abstracts


Surface Electrocardiographic Patterns and Electrophysiologic Characteristics of Atrial Flutter Following Modified Radiofrequency MAZE Procedures

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 4 2007
JOSEPH G. AKAR M.D., Ph.D.
Introduction: The radiofrequency MAZE is becoming a common adjunct to cardiac surgery in patients with atrial fibrillation. While a variety of postoperative arrhythmias have been described following the original Cox-MAZE III procedure, the electrophysiological characteristics and surgical substrate of post-radiofrequency MAZE flutter have not been correlated. We sought to determine the location, ECG patterns, and electrophysiological characteristics of post-radiofrequency MAZE atrial flutter. Methods: Nine consecutive patients with post-radiofrequency MAZE flutter presented for catheter ablation 9 ± 10 months after surgery. Results: Only one patient (11%) had an ECG appearance consistent with typical isthmus-dependent right atrial (RA) flutter. However, on electrophysiological study, 3/9 patients (33%) had typical right counter-clockwise flutter entrained from the cavo-tricuspid isthmus, despite description of surgical isthmus ablation. Six patients (67%) had left atrial (LA) circuits. These involved the mitral annulus in 5/6 cases (83%) despite description of surgical mitral isthmus ablation in the majority (60%). LA flutters had a shorter cycle length compared with RA flutters (253 ± 39 msec and 332 ± 63 msec respectively, P < 0.05). After a mean of 8 ± 4 months following ablation, 8/9 patients (89%) were in sinus rhythm. Conclusion: Up to one-third of post-radiofrequency MAZE circuits are typical isthmus-dependent RA flutters, despite a highly atypical surface ECG morphology. Therefore, diagnostic electrophysiological studies should commence with entrainment at the cavo-tricuspid isthmus in order to exclude typical flutter, regardless of the surface ECG appearance. Incomplete surgical lesions at the mitral and cavo-tricuspid isthmus likely predispose to the development of post-radiofrequency MAZE flutter. [source]


Atrial Size Reduction as a Predictor of the Success of Radiofrequency Maze Procedure for Chronic Atrial Fibrillation in Patients Undergoing Concomitant Valvular Surgery

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 8 2001
MIEN-CHENG CHEN M.D.
Radiofrequency Maze Procedure and Atrial Size.Introduction: Previous studies showed that the surgical maze procedure can restore sinus rhythm and atrial transport function in patients with chronic atrial fibrillation (AF). However, no previous studies discussed the association of atrial size reduction and the success of sinus conversion by the radiofrequency (RF) maze procedure for chronic AF. Methods and Results: A total of 119 chronic AF patients undergoing valvular operations were included in this study. Sixty-one patients received RF and cryoablation to create lesions in both atria to simulate the surgical maze II or III procedure (RF maze II or RF maze III; 13 patients, group 1) or a modified maze pattern (RF maze "IV"; 48 patients, group 2). The other 58 patients who underwent valvular operations alone without the maze procedure served as control (group 3). At 3-month follow-up after operation, sinus rhythm was restored in 73%, 81%, and 11% of patients in groups 1, 2 and 3, respectively. Preoperative left and right atrial sizes were not statistically significant predictors of sinus conversion by the RF maze procedure. However, as a result of postoperative reduction of atrial sizes, postoperative left atrial diameter was significantly smaller in patients who had sinus conversion by the RF maze procedure than in patients who did not regain sinus rhythm (45.0 ± 7.0 mm vs 51.0 ± 8.0 mm; P = 0.03). Postoperative right atrial area of patients who had sinus conversion by the RF maze procedure also was significantly smaller than that of patients who did not regain sinus rhythm (18.1 ± 4.4 cm2 vs 28.5 ± 8.2 cm2; P = 0.008). Conclusion: Atrial size reduction appears to predict the success of sinus conversion with the RF maze procedure used in conjunction with valvular surgery. [source]


Percutaneous Catheter Ablation Procedures for the Treatment of Atrial Fibrillation

JOURNAL OF CARDIAC SURGERY, Issue 3 2004
Anthony R. Magnano M.D.
Given the success of the surgical Maze procedure, initial catheter-based approaches involved creation of linear atrial lesions. Success rates were low and utility was limited by a high complication rate and long procedural times. The recent discovery that AF is often initiated by atrial ectopic beats has resulted in therapies designed to target the ectopic sources, particularly those within the pulmonary veins. Experience and technological advances have improved the efficacy and safety of such procedures. This article will review catheter ablation procedures for the maintenance of sinus rhythm in patients with AF. (J Card Surg 2004;19:188-195) [source]


Surgical Ablation of Permanent Atrial Fibrillation by Means of Maze Radiofrequency:

JOURNAL OF CARDIAC SURGERY, Issue 5 2004
Mid-Term Results
We report our experience with a biatrial pattern of lesions based on the use of epicardial and endocardial radiofrequency ablation in an effort to minimize maze procedure. Method: In 85 patients undergoing cardiac surgery for established permanent atrial fibrillation (>3 months), a biauricular pattern of epicardic,endocardic maze lesions was performed. The main surgical procedures were diverse: 42 mitral valve surgeries, 7 mitrotricuspid valves, 18 mitroaortics, 4 mitroaortic and tricuspids, 2 aortic valves, 3 CABGs, 5 CABG and valve procedures, and 4 atrial septal defects. The mean age of the patients was 61 ± 12 (range 39,78). The mean duration of atrial fibrillation was 5.8 years (range 0.3 to 24). Results: Sixty-two (72.9%) patients presented postoperative supraventricular arrhythmia. Hospital mortality was seen in five patients (5.8%). Two patients died after a 12-month mean follow-up (range 2 to 32). A total of 14.1% of patients remained with their previous atrial fibrillation and 85.9% recovered and maintained sinus rhythm, with two patients having a permanent pacemaker. A total of 56% patients have been followed-up for a period of more than 6 months, and among them prevalence of sinus rhythm is 87.5%. Echocardiography detected biauricular contraction in 65% of them. After analyzing the data, factors involved in postoperative recurrence of atrial fibrillation after radiofrequency surgery were oldness of the atrial fibrillation (p < 0.01) and pre and postoperative left auricle volume (p < 0.04). Conclusion: Intraoperative radiofrequency has permitted us to perform the maze procedure in a simple way, with a low surgical morbid-mortality. We have obtained an 85.9% electrographic effectiveness and a 65% recovery of atrial contraction. Postoperative incidence of arrhythmia is the main postoperative problem. [source]


Atrial Size Reduction as a Predictor of the Success of Radiofrequency Maze Procedure for Chronic Atrial Fibrillation in Patients Undergoing Concomitant Valvular Surgery

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 8 2001
MIEN-CHENG CHEN M.D.
Radiofrequency Maze Procedure and Atrial Size.Introduction: Previous studies showed that the surgical maze procedure can restore sinus rhythm and atrial transport function in patients with chronic atrial fibrillation (AF). However, no previous studies discussed the association of atrial size reduction and the success of sinus conversion by the radiofrequency (RF) maze procedure for chronic AF. Methods and Results: A total of 119 chronic AF patients undergoing valvular operations were included in this study. Sixty-one patients received RF and cryoablation to create lesions in both atria to simulate the surgical maze II or III procedure (RF maze II or RF maze III; 13 patients, group 1) or a modified maze pattern (RF maze "IV"; 48 patients, group 2). The other 58 patients who underwent valvular operations alone without the maze procedure served as control (group 3). At 3-month follow-up after operation, sinus rhythm was restored in 73%, 81%, and 11% of patients in groups 1, 2 and 3, respectively. Preoperative left and right atrial sizes were not statistically significant predictors of sinus conversion by the RF maze procedure. However, as a result of postoperative reduction of atrial sizes, postoperative left atrial diameter was significantly smaller in patients who had sinus conversion by the RF maze procedure than in patients who did not regain sinus rhythm (45.0 ± 7.0 mm vs 51.0 ± 8.0 mm; P = 0.03). Postoperative right atrial area of patients who had sinus conversion by the RF maze procedure also was significantly smaller than that of patients who did not regain sinus rhythm (18.1 ± 4.4 cm2 vs 28.5 ± 8.2 cm2; P = 0.008). Conclusion: Atrial size reduction appears to predict the success of sinus conversion with the RF maze procedure used in conjunction with valvular surgery. [source]


Mini-Maze Suffices as Adjunct to Mitral Valve Surgery in Patients with Preoperative Atrial Fibrillation

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 9 2000
ANTON E. TUINENBURG M.D.
Mini-Maze and Mitral Valve Surgery. Introduction: After mitral valve (MV) surgery, preoperative atrial fibrillation (AF) often recurs while cardioversion therapy generally fails. Additional Cox maze surgery improves postoperative arrhythmia outcome, but the extensive nature of such an approach limits general appliance. We investigated the clinical outcome of a simplified, less extensive Cox maze procedure ("mini-maze") as adjunct to MV surgery. Methods and Results: Thirteen patients with MV disease and preoperative AF were treated with combined surgery (group 1). Nine control patients without previous AF underwent isolated MV surgery (group 2). We retrospectively compared the results to findings in 23 patients with preoperative AF who had undergone isolated MV surgery (group 3). In group 1, mini-maze took an additional 46 minutes of perfusion time. One 75-year-old patient died of postoperative multiple organ failure. Seven patients showed spontaneously converting (within 2 months) postoperative AF. After 1 year, 82% were in sinus rhythm (SR). No sinus node dysfunction was observed. In group 2, all patients were in SR after 1 year. In group 3, only 53% were in SR after 1 year, despite serial cardioversion and antiarrhythmic drug therapy. Exercise tolerance and heart rate were comparable for groups 1 and 2. Left atrial function was present in all but one patient in group 1 and in all patients in group 2 (after MV reconstruction). Conclusion: Adding a relatively simple mini-maze to MV surgery improves arrhythmia outcome in patients with preoperative AF without introducing sinus node dysfunction or persistent absence of left atrial function. The results of this type of combined surgery are encouraging and deserve further attention. [source]