Maximum Torque (maximum + torque)

Distribution by Scientific Domains


Selected Abstracts


Accelerator adsorption onto carbon nanotubes surface affects the vulcanization process of styrene,butadiene rubber composites

JOURNAL OF APPLIED POLYMER SCIENCE, Issue 5 2009
A. De Falco
Abstract The multiwalled carbon nanotubes (MWCNT) filled styrene,butadiene rubber (SBR) composites were prepared by incorporating MWCNT in a SBR/toluene solution and subsequently evaporating the solvent. These composites have shown a significant improvement in Young's modulus and tensile strength with respect to SBR gum without sacrificing high elongation at break. However, this improvement is less than expected at the higher filler content. Then, the influence of low concentrations of MWCNT on the vulcanization process of the SBR composites was studied by means of rheometer torque curves, swelling measurements, differential scanning calorimeter (DSC) analysis, and Fourier transform infrared (FTIR) spectroscopy. Also, their thermal degradation was studied by thermogravimetric analysis (TGA). It has been noticed that MWCNT affects the cure kinetics of SBR gum matrix reducing all parameters, i.e., the total heat rate and order of the reaction, scorch delay, maximum torque, and crosslink density. This effect increases as MWCNT content does, and it was attributed to the adsorption of the accelerator employed in the vulcanization (N -tert-butyl-benzothiazole-2-sulfenamide) onto the MWCNT surface. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2009 [source]


Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement

JOURNAL OF ORAL REHABILITATION, Issue 12 2006
I. TURKYILMAZ
summary, The aim of this study was to determine the bone density in the designated implant sites using computerized tomography (CT), the fastening torque values of dental implants, and the implant stability values using resonance frequency analysis. Further aim was to evaluate a possible correlation between bone density, fastening torque and implant stability. Eighty-five patients were treated with 158 Brånemark System implants. CT machine was used for preoperative evaluation of the jawbone for each patient, and bone densities were recorded in Hounsfield units (HU). The fastening torque values of all implants were recorded with the OsseoCare equipment. Implant stability measurements were performed with the Osstell machine. The average bone density and fastening torque values were 751·4 ± 256 HU and 39·7 ± 7 Ncm for 158 implants. The average primary implant stability was 73·2 ± 6 ISQ for seventy implants. Strong correlations were observed between the bone density, fastening torque and implant stability values of Brånemark System TiUnite MKIII implants at implant placement (P < 0·001). These results strengthen the hypothesis that it may be possible to predict and quantify initial implant stability and bone quality from pre-surgical CT diagnosis. [source]


Low intensity pulsed ultrasound accelerated bone remodeling during consolidation stage of distraction osteogenesis

JOURNAL OF ORTHOPAEDIC RESEARCH, Issue 2 2006
Chun Wai Chan
Abstract Bone regeneration in distraction osteogenesis occurs under tensile stress with axial rhythmic distraction after osteotomy. In this study, we evaluated if the low intensity pulsed ultrasound (LIPUS) was also effective on enhancement of bone remodeling during consolidation stage of distraction osteogenesis. Open osteotomy of seventeen 18-week-old female New Zealand rabbit tibiae were performed. The distraction was applied with the rate of 1 mm per day. LIPUS (30 mW/cm2, 1.5 MHz) was delivered for 20 min per day during 4-week consolidation stage (n,=,10). The animals without treatment served as sham group (n,=,7). Plain X-ray, peripheral quantitative computational tomography (pQCT), and torsional test were performed. Results showed that smaller radiolucent interzone of LIPUS treatment group was gradually occupied by calcified tissue in plain X-ray at week 2. The bone mineral density (BMD) measured on radiographs increased by 9.18% in the LIPUS group. Bone mineral content (BMC), hard callus volume, and bone strength index (BSI) measured by pQCT were 83%, 116%, and 94%, respectively, in LIPUS group that were significantly greater than those of the controls. At the 4th week, LIPUS-treated callus showed the development of neocorticalization in the proximal and distal region. The BMC, hard callus volume, and BSI of LIPUS group decreased and was not significantly different from control. This was also confirmed by the maximum torque of LIPUS-treated callus (1424.2,±,457.3 N,·,mm) obtained at week 4, which did not differ from that of the sham group (1968.8,±,895.1 N,·,mm). In conclusion, the effective period of LIPUS treatment was at the initial stage of consolidation, with accelerated bone formation and remodeling. © 2005 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res [source]


Repair of rabbit segmental defects with the thrombin peptide, TP508

JOURNAL OF ORTHOPAEDIC RESEARCH, Issue 5 2004
Michael R. Sheller
Abstract The synthetic peptide, TP508 (Chrysalin®), was delivered to rabbit segmental bone defects in biodegradable controlled-release PLGA microspheres to determine its potential efficacy for enhancing healing of non-critically and critically sized segmental defects. Non-critically sized radial defects were created in the forelimbs of New Zealand White rabbits, which were randomized into three treatment groups receiving 10, 50 and 100 ,g doses of TP508 in the right radius and control microspheres (without TP508) in the left radius. Torsional testing of the radii at six weeks showed a significant increase in ultimate torque, failure torque, ultimate energy, failure energy, and stiffness when treated with TP508 compared to controls (p < 0.01 for all measures). Thus, TP508 appeared to enhance or accelerate bone growth in these defects. In a second set of experiments, critically sized ulnar defects were created in the forelimbs of New Zealand White rabbits, which were randomized into two groups with each rabbit receiving microspheres with 100 or 200 ,g of TP508 into the right ulnar defect and control microspheres (without TP508) alone into the left ulnar defect. Bone healing was evaluated with plain radiographs, synchrotron-based microtomography, and mechanical testing. Radiographs of the rabbit limbs scored by three blinded, independent reviewers demonstrated a significantly higher degree of healing when treated with TP508 than their untreated control limbs (p < 0.05). Three-dimensional synchrotron tomography of a limited number of samples showed that the new bone in TP508-treated samples had a less porous surface appearance and open marrow spaces, suggesting progression of bone remodeling. Torsional testing of the ulnae at nine weeks showed a significant increase in maximum torque and failure energy when treated with TP508 compared to controls (p < 0.01 for both measures). These results suggest that TP508 in a controlled release delivery vehicle has the potential to enhance healing of segmental defects in both critically and non-critically sized defects. © 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved. [source]


Influence of operating conditions on friction and temperature characteristics of a wet clutch engagement

LUBRICATION SCIENCE, Issue 2 2000
Mikael HolgersonArticle first published online: 9 MAR 200
Abstract To optimise the gear change in automatic transmissions, more knowledge is needed of the engagement behaviour of wet clutches. A factorial design investigation of the engagement of a wet clutch has been carried out. The friction and temperature characteristics have been studied. The experiments were carried out in an apparatus that can vary sliding velocity, drive torque, inertia, force rate, and lubricant flow. The results show how these parameters affect the response data: engagement time, developed energy, temperature rise, maximum torque, maximum power, static friction, dynamic friction, and initial friction. There are interaction effects between some of the input parameters, but they are relatively small. The friction coefficient varies over time but is independent of the input parameters, except for dynamic friction, which decreases with increasing sliding velocity, drive torque, and inertia. The temperature rise was found to be proportional to developed energy and both these were most affected by sliding velocity. The drive torque and force rate have the greatest effect on the engagement time. [source]


Recycling of silicone rubber waste: Effect of ground silicone rubber vulcanizate powder on the properties of silicone rubber

POLYMER ENGINEERING & SCIENCE, Issue 2 2003
Arun Ghosh
The silicone rubber vulcanizate powder (SVP) obtained from silicone rubber by mechanical grinding exists in a highly aggregated state. The particle size distribution of SVP is broad, ranging from 2 µm to 110 µm with an average particle size of 33 µm. X-ray Photoelectron Spectroscopy (XPS) and Infrared (IR) Spectroscopy studies show that there is no chemical change on the rubber surface following mechanical grinding of the heat-aged (200°C/10 days) silicone rubber vulcanizate. Addition of SVP in silicone rubber increases the Mooney viscosity, Mooney scorch time, shear viscosity and activation energy for viscous flow. Measurement of curing characteristics reveals that incorporation of SVP into the virgin silicone rubber causes an increase in minimum torque, but marginal decrease in maximum torque and rate constant of curing. However, the activation energy of curing shows an increasing trend with increasing loading of SVP. Expectedly, incorporation of SVP does not alter the glass-rubber transition and cold crystallization temperatures of silicone rubber, as observed in the dynamic mechanical spectra. It is further observed that on incorporation of even a high loading of SVP (i.e., 60 phr), the tensile and tear strength of the silicone rubber are decreased by only about 20%, and modulus dropped by 15%, while the hardness, tension set and hysteresis loss undergo marginal changes and compression stress-relaxation is not significantly changed. Atomic Force Microscopy studies reveal that incorporation of SVP into silicone rubber does not cause significant changes in the surface morphology. [source]


An initial investigation on torsional properties of nickel-titanium instruments produced with a new manufacturing method

AUSTRALIAN ENDODONTIC JOURNAL, Issue 2 2009
Gianluca Gambarini md
Abstract A new manufacturing process involving twisting of a ground blank combined with heat treatment has been recently developed to produce nickel-titanium rotary files for root canal preparation. The aim of this study was to compare torsional resistance of prototype instruments produced using the new manufacturing method versus traditional nickel-titanium instruments produced by the customary grinding process. Twenty prototypes instruments of the same design and dimensions were divided in two groups of 10 each, according to the different manufacturing method. A file-testing apparatus specifically designed to perform torsional testing was used in accordance with the International Organization for Standardization 3630-1. The results indicated that instruments manufactured by the new manufacturing process demonstrated significantly higher average maximum torque levels than those manufactured by the existing grinding process (P < 0.05). Since instruments design and dimensions of the instruments were the same, the different manufacturing process could be the only explanation for this improvement in torsional resistance. [source]


Utilization of bowstring hemp fiber as a filler in natural rubber compounds

JOURNAL OF APPLIED POLYMER SCIENCE, Issue 1 2008
E. Osabohien
Abstract The cure characteristics and physicomechanical properties of natural rubber (standard Nigerian rubber) vulcanizates filled with the fiber of bowstring hemp (Sansevieria liberica) and carbon black were investigated. The results showed that the scorch and cure times decreased, whereas the maximum torques increased, with increasing filler loadings for both bowstring hemp fiber and carbon black filled vulcanizates. The tensile strength of both bowstring hemp fiber and carbon black filled vulcanizates increased to a maximum at a 40 phr filler concentration before decreasing. The elongation at break and rebound resilience decreased, whereas the modulus, specific gravity, abrasion resistance, and hardness increased, with increasing filler contents. The carbon black/natural rubber vulcanizates had higher tensile strength, which was about 1.5 times that of bowstring hemp fiber/natural rubber vulcanizates. This superiority in the tensile strength was probably due to the higher moisture content and larger particle size of the bowstring hemp fiber. However, the bowstring hemp fiber/natural rubber vulcanizates showed superior hardness. © 2007 Wiley Periodicals, Inc. J Appl Polym Sci, 2008 [source]