Load Values (load + value)

Distribution by Scientific Domains


Selected Abstracts


An acoustic emission study on the fracture behavior of continuous glass fiber/polypropylene composites based on commingled yarn

POLYMER COMPOSITES, Issue 7 2008
Yantao Wang
The fracture behavior of continuous glass fiber reinforced polypropylene composites made of commingled yarn in the form of biaxial (±±45°) noncrimp warp-knitted fabric, twill woven fabric, and swirl mat, respectively, was investigated by virtue of single edge notched tensile (SEN-T) specimens. These composite laminates were manufactured by compression molding and cooled at two different rates (1°C/min and 10°C/min) during the last processing phase of the laminates. The failure mechanisms were studied by acoustic emission (AE) analysis. AE amplitude ranges corresponding to the individual failure modes have been identified. For biaxial noncrimp fabric reinforced materials, the failure mechanisms involved in the fracture procedure are governed by the interface related failure events. Higher cooling rate, which is accompanied by better fiber/matrix adhesion, results in not only the increase in the relative proportion of high-amplitude failure events, but also the occurrence of a large quantity of fiber fracture events. For woven fabric and mat reinforced composites, fiber-dominated failure mechanisms result in the higher fracture toughness when compared with biaxial noncrimp fabric composites. Under this circumstance, the change in cooling rate only results in the difference in the relative frequency of the individual failure modes. In addition, it is found out that the initiation fracture toughness of SEN-T specimens can be easily assessed by marking the load value which corresponds to the first point of AE signals emitted stably in AE events-displacement curves. POLYM. COMPOS., 2008. © 2008 Society of Plastics Engineers [source]


The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study

CLINICAL ORAL IMPLANTS RESEARCH, Issue 6 2008
Simon Rupert Allum
Abstract Objectives: While caution in the use of small-diameter (,3.5 mm) implants has been advocated in view of an increased risk of fatigue fracture under clinical loading conditions, a variety of implant designs with diameters <3 mm are currently offered in the market for reconstructions including fixed restorations. There is an absence of reported laboratory studies and randomized-controlled clinical trials to demonstrate clinical efficacy for implant designs with small diameters. This laboratory study aimed to provide comparative data on the mechanical performance of a number of narrow commercially marketed implants. Materials and methods: Implants of varying designs were investigated under a standardized test set-up similar to that recommended for standardized ISO laboratory testing. Implant assemblies were mounted in acrylic blocks supporting laboratory cast crowns and subjected to 30° off-axis loading on an LRX Tensometer. Continuous output data were collected using Nexygen software. Results: Load/displacement curves demonstrated good grouping of samples for each design with elastic deformation up to a point of failure approximating the maximum load value for each sample. The maximum loads for Straumann (control) implants were 989 N (±107 N) for the 4.1 mm RN design, and 619 N (±50 N) for the 3.3 mm RN implant (an implant known to have a risk of fracture in clinical use). Values for mini implants were recorded as 261 N (±31 N) for the HiTec 2.4 mm implant, 237 N (±37 N) for the Osteocare 2.8 mm mini and 147 N (±25 N) for the Osteocare mini design. Other implant designs were also tested. Conclusions: The diameters of the commercially available implants tested demonstrated a major impact on their ability to withstand load, with those below 3 mm diameter yielding results significantly below a value representing a risk of fracture in clinical practice. The results therefore advocate caution when considering the applicability of implants ,3 mm diameter. Standardized fatigue testing is recommended for all commercially available implants. [source]


RANKL Inhibition with Osteoprotegerin Increases Bone Strength by Improving Cortical and Trabecular bone Architecture in Ovariectomized Rats,,

JOURNAL OF BONE AND MINERAL RESEARCH, Issue 5 2008
Michael S Ominsky
Abstract Introduction: Ovariectomy (OVX) results in bone loss caused by increased bone resorption. RANKL is an essential mediator of bone resorption. We examined whether the RANKL inhibitor osteoprotegerin (OPG) would preserve bone volume, density, and strength in OVX rats. Materials and Methods: Rats were OVX or sham-operated at 3 mo of age. Sham controls were treated for 6 wk with vehicle (Veh, PBS). OVX rats were treated with Veh or human OPG-Fc (10 mg/kg, 2/wk). Serum RANKL and TRACP5b was measured by ELISA. BMD of lumbar vertebrae (L1,L5) and distal femur was measured by DXA. Right distal femurs were processed for bone histomorphometry. Left femurs and the fifth lumbar vertebra (L5) were analyzed by ,CT and biomechanical testing, and L6 was analyzed for ash weight. Results: OVX was associated with significantly greater serum RANKL and osteoclast surface and with reduced areal and volumetric BMD. OPG markedly reduced osteoclast surface and serum TRACP5b while completely preventing OVX-associated bone loss in the lumbar vertebrae, distal femur, and femur neck. Vertebrae from OPG-treated rats had increased dry and ash weight, with no significant differences in tissue mineralization versus OVX controls. ,CT showed that trabecular compartments in OVX-OPG rats had significantly greater bone volume fraction, vBMD, bone area, trabecular thickness, and number, whereas their cortical compartments had significantly greater bone area (p < 0.05 versus OVX-Veh). OPG improved cortical area in L5 and the femur neck to levels that were significantly greater than OVX or sham controls (p < 0.05). Biomechanical testing of L5 and femur necks showed significantly greater maximum load values in the OVX-OPG group (p < 0.05 versus OVX-Veh). Bone strength at both sites was linearly correlated with total bone area (r2 = 0.54,0.74, p < 0.0001), which was also significantly increased by OPG (p < 0.05 versus OVX). Conclusions: OPG treatment prevented bone loss, preserved trabecular architecture, and increased cortical area and bone strength in OVX rats. [source]


Molecular epidemiology of hepatitis B virus in Dakar, Sénégal

JOURNAL OF MEDICAL VIROLOGY, Issue 3 2006
Muriel Vray
Abstract Using DNA chip technology and real-time quantitative PCR, molecular profile of HBV strains infecting blood donors and patients in Dakar, Sénégal was studied. All HBsAg-positive blood donors (n,=,175) and all patients who presented with chronic hepatitis B (n,=,29) between 1st June 2003 and 31st July 2003 were studied. One patient, a blood donor, was coinfected by HCV, and nine patients had anti-HDV antibodies. Few persons in either group were HBeAg-positive. Viral load values were relatively low but correlated with biochemical abnormalities. Patients were infected mainly by genotype E (72%). Patients infected by genotype A (28%) tended to be younger than other patients. There was no significant difference between the blood donors and the patients with hepatitis B as regards virological markers, including viral load, when the HBV genotype was taken into account. The BCP A1762T and G1764A mutations were found in four patients and one patient, respectively; the two mutations were never found in the same patient. The W28* mutation at position 1896 of the core was detected in 19 of the 32 genotyped patients, 18 (83%) of whom had genotype E infection. ALT levels were not influenced by HBV mutations. This study shows a low frequency of clinical signs in HBsAg-positive blood donors, a relatively low level of viral replication, and a high frequency of pre-core mutants in this West African population. These results underline the importance of molecular characterization of HBV infection as specific treatments become available in this region. J. Med. Virol. 78:329,334, 2006. © 2006 Wiley-Liss, Inc. [source]


Monitoring the response to antiretroviral therapy in HIV-1 group O infected patients using two new RT-PCR assays

JOURNAL OF MEDICAL VIROLOGY, Issue 3 2001
Carmen de Mendoza
Abstract Failure to recognise infection caused by human immunodeficiency virus type 1 (HIV-1) group O variants has been described using both serological and genetic procedures. Moreover, monitoring the response to antiretroviral therapy is a difficult task in patients infected with HIV-1 group O since commercial tests are not available so far for the quantitation of this virus. In this study, the virological response to antiretroviral therapy were assessed in five HIV-1 group O-infected patients living in Spain by using two new and different RT-PCR methods (MUPROVAMA and LCx). Twenty-four plasma samples belonging to these five patients were selected. As reference, p24 antigenaemia levels and CD4+ cell counts were used. All samples yielded positive viral load values using MUPROVAMA (range: 138 to 595,500 HIV-RNA copies/ml) and 23 of 24 using LCx (range: <,178 to 98,356 HIV-RNA copies/ml). Overall, the results obtained using both assays showed a good correlation among themselves, and in respect to p24 antigenaemia and CD4+ cell counts. However, the values provided by LCx were significantly lower (0.33 logs on average) than those provided by MUPROVAMA. In conclusion, both the highly sensitive MUPROVAMA and LCx Quantitative assays might represent an useful tool for guiding the decision on when start treatment and for monitoring the response to antiretroviral therapy in HIV-1 group O-infected patients. J. Med. Virol. 64:217,222, 2001. © 2001 Wiley-Liss, Inc. [source]


Mechanical Behavior and Failure Analysis of Prosthetic Retaining Screws after Long-term Use In Vivo.

JOURNAL OF PROSTHODONTICS, Issue 3 2008
Part 1: Characterization of Adhesive Wear, Structure of Retaining Screws
Abstract Purpose: The general aim of this study and those presented in Parts 2,4 of this series was to characterize the structure, properties, wear, and fracture of prosthetic retaining screws in fixed detachable hybrid prostheses after long-term use in vivo. This part of the overall investigation addresses whether there are differences in thread wear between the screws closest to the fulcrum and those that are farthest from the fulcrum in fixed detachable hybrid prostheses. Materials and Methods: The total number of prosthetic retaining screws used in this study was 100 (10 new and 90 used). New screws (controls) from Nobel Biocare (NB) were divided into Group 1 (slotted) and Group 2 (hexed). Ninety used screws (in service 18,120 months) were retrieved from fixed detachable hybrid prostheses in 18 patients (5 screws from each patient, 60 from NB and 30 from Sterngold). The used screws were divided into 18 groups. Additionally, each group was subdivided into A and B categories. Category A contained the middle three prosthetic screws, which were considered the farthest screws from the fulcrum line. Category B contained the most posterior two screws, which were considered the screws closest to the fulcrum line. All 100 screws were subjected to thorough, nondestructive testing. Results: Light and scanning electron microscopic examination of all used screws for each group revealed surface deterioration of the active profile of the screw threads consistent with adhesive wear. The observed thread profile deterioration ranged from mild to severe. The wear was aggressive enough to cause galling, which led to thinning of the threads and, in severe cases, to knife-edges at thread crests. In ten groups, the most anterior three screws exhibited more wear than the most posterior two screws. In addition to thread wear, severe plastic deformation was detected on the bottom part of each screw for three groups, and a long external longitudinal crack was detected in one screw of Group 2. Conclusions: The findings of this study and those presented in Parts 2,4 demonstrate that different retaining screws from the same manufacturer and/or from different manufacturers have different geometrical design, microstructures, major alloy constituents, and microhardness, and that these differences influence their preload and fractured load values. In this part of the overall investigation, the occurrence of galling as a result of wear involving prosthetic retaining screws appears to be an inevitable and unavoidable consequence of long-term use in vivo in fixed detachable hybrid prostheses regardless of the intended/original preload value. The galling rate is greater on the middle three screws compared to the most posterior two screws in fixed detachable hybrid prostheses. The wear pattern is consistent with an adhesive wear mechanism; however, this study does not provide enough data to support a definitive analysis. [source]


CAD/CAM to fabricate ceramic implant abutments and crowns: a preliminary in vitro study

AUSTRALIAN DENTAL JOURNAL, Issue 1 2009
MA Alfarsi
Abstract Background:, This study evaluated the feasibility of fabricating implant abutments and crowns from pre-sintered feldspathic porcelain blocks using the chair-side CAD/CAM, CEREC3D® system. Methods:, Thirty-two implant analogues were divided into two groups. In the control group, prefabricated machined anatomical titanium (Ti) abutments were screw-retained to the analogues. In the test group, machined feldspathic porcelain abutments were cemented on prefabricated machined Ti links and screw-retained to the implant analogues. These feldspathic porcelain abutments were fabricated out of pre-sintered feldspathic porcelain blocks as duplicates of the abutments in the control group using the CAD/CAM, CEREC3D® system. Thirty-two feldspathic porcelain crowns, also fabricated out of pre-sintered ceramic blocks, were then cemented with resin cement on all the abutments in both groups. All samples were subsequently subjected to fracture strength testing under static load. An unpaired t-test was used to compare fracture load values between the two groups. Results:, The test group using feldspathic porcelain abutments and crowns showed statistically significant higher mean fracture strength than the control group with the Ti abutments and feldspathic porcelain crowns. Conclusions:, This preliminary study showed that the chair-side CAD/CAM technology can be utilized to fabricate customized ceramic abutments with their associated ceramic crowns using pre-sintered feldspathic porcelain blocks. [source]