Kappa Values (kappa + value)

Distribution by Scientific Domains
Distribution within Medical Sciences


Selected Abstracts


A UK-based investigation of inter- and intra-observer reproducibility of Gleason grading of prostatic biopsies

HISTOPATHOLOGY, Issue 6 2006
J Melia
Aims:, The frequency of prostatic core biopsies to detect cancer has been increasing with more widespread prostate specific antigen (PSA) testing. Gleason score has important implications for patient management but morphological reproducibility data for British practice are limited. Using literature-based criteria nine uropathologists took part in a reproducibility study. Methods:, Each of the nine participants submitted slides from consecutive cases of biopsy-diagnosed cancer assigned to the Gleason score groups 2,4, 5,6, 7 and 8,10 in the original report. A random selection of slides was taken within each group and examined by all pathologists, who were blind to the original score. Over six circulations, new slides were mixed with previously read slides, resulting in a total of 47 of 81 slides being read more than once. Results:, For the first readings of the 81 slides, the agreement with the consensus score was 78% and overall interobserver agreement was , 0.54 for Gleason score groups 2,4, 5,6, 7, 8,10. Kappa values for each category were 0.33, 0.56, 0.44 and 0.68, respectively. For the 47 slides read more than once, intra-observer agreement was 77%, , 0.66. The study identified problems in core biopsy interpretation of Gleason score at levels 2,4 and 7. Patterns illustrated by Gleason as 2 tended to be categorized as 3 because of the variable acinar size and unassessable lesional margin. In slides with consensus Gleason score 7, 13% of readings were scored 6 and in slides with consensus 6, 18% of readings were scored 7. Conclusions:, Recommendations include the need to increase objectivity of the Gleason criteria but limits of descriptive morphology may have to be accepted. [source]


A comparison between clearing and radiographic techniques in the study of the root-canal anatomy of maxillary first and second molars

INTERNATIONAL ENDODONTIC JOURNAL, Issue 5 2004
O. E. Omer
Abstract Aim, To compare a clearing technique with conventional radiography in studying certain features of the root-canal system of maxillary right first and second molars. A secondary aim was to assess interexaminer agreement for these features using radiographs. Methodology, Eighty-three recently extracted permanent maxillary right first molars and 40 recently extracted maxillary right second molars from an Irish population were included. Standard periapical radiographs were taken from a buccolingual and mesiodistal direction. The specimens were then decoronated, demineralized in 10% hydrochloric acid for 8 days and then cleared using methyl salicylate. The cleared teeth were examined using a dissecting microscope (×20), and data relating to number of roots, canal type following Vertucci's classification, presence of lateral canals, presence of transverse anastomoses and position/number of apical foramina were collected. The radiographs were examined by two independent trained endodontists using an X-ray viewer and a magnifying lens (×2) in a dark room for the same features studied using the clearing technique. Results, The Kappa values for the agreement between the radiographic examiners A and B and the clearing technique and between the two examiners for the number of roots were 0.60, 0.64 and 0.53; for the root-canal type, 0.37, 0.41 and 0.42; for the number of roots with lateral canals, 0.21, 0.18 and 0.14; and for the transverse anastomoses, 0.29 for radiographic Examiner A. Radiographic Examiner B did not feel capable of accurately recognizing transverse anastomoses from the radiographs. For the position/number of apical foramina, the Kappa values were 0.33 and 0.24, respectively. In general, the Kappa values were low to modest for all comparisons. Conclusions, It is concluded that the agreement between the two radiographic examiners and the agreement between either radiographic examiner and the clearing technique were poor to moderate, indicating the limited value of radiographs alone when studying certain aspects of the root-canal system. [source]


Agreement between self-reported and pharmacy data on medication use in the Northern Finland 1966 Birth Cohort

INTERNATIONAL JOURNAL OF METHODS IN PSYCHIATRIC RESEARCH, Issue 2 2010
Marianne Haapea
Abstract Objective: To compare self-reported (SR) medication use and pharmacy data for major psychoactive medications and three classes of medications used for different indications, and to determine the socio-economic factors associated with the congruence. Methods: Postal questionnaire data collected in 1997 were compared with the register of the Social Insurance Institution of Finland on the reimbursed prescriptions purchased during 1997. Altogether 7625 subjects were included in this study. Drugs were categorized according to the Anatomical Therapeutic Chemical (ATC) system. Results: Kappa values were 0.77, 0.68, 0.84, 0.92 and 0.55 for antipsychotics, antidepressants, antiepileptics, antidiabetics and beta-blocking agents, respectively. Prevalence-adjusted and bias-adjusted kappa values were almost perfect (0.98,1.00). Reliability of antipsychotics use was better for married subjects than for those who were not married; and of antidepressants use for highly educated and married subjects than for those who were less educated and were not married. Altogether 414 (5.4%) responders and 285 (7.1%) non-responders had used at least one of the selected medications. Conclusion: Agreement between the SR and pharmacy data was moderate for psychoactive medication use. Even though data collected by postal questionnaire may underestimate the prevalence of medication use due to non-participation it can be assumed accurate enough for study purposes. Copyright © 2010 John Wiley & Sons, Ltd. [source]


Root resorption in retained deciduous canine and molar teeth without permanent successors in patients with severe hypodontia

INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, Issue 3 2001
K. Haselden
Aims. The ability to predict the morbidity of retained deciduous teeth with no permanent successors, a characteristic of hypodontia, would be of considerable value in treatment planning, but is hampered by lack of data. Methods. This problem was studied using 356 orthopantomogram radiographs (OPGs) from the records of 249 patients who had attended a specialist hypodontia clinic, and had retained deciduous teeth with no permanent successors. Due to their clinical importance, canine and molar teeth were chosen for examination. Resorption was assessed subjectively by three experienced clinicians. Results. Un-weighted Kappa values for reproducibility were > 0·8, and for inter-observer error 0·60,0·83. Gender related differences were minimal. Regardless of gender or radiographic age, the lower canines appear to show the least amount of resorption and the upper first molars the most. The upper and lower second molars have particularly unpredictable life spans. Whilst the lower first molars have a predictable life span that is poor, the life span for the upper first molars is slightly worse. Conclusions. Lower canines have a predictable life span that appears to be good, as do upper canines, but of lesser duration than lower canines. Molars have poorer and less predictable life spans. [source]


Modelling the distributions of Culicoides bluetongue virus vectors in Sicily in relation to satellite-derived climate variables

MEDICAL AND VETERINARY ENTOMOLOGY, Issue 2 2004
B. V. Purse
Abstract., Surveillance data from 268 sites in Sicily are used to develop climatic models for prediction of the distribution of the main European bluetongue virus (BTV) vector Culicoides imicola Kieffer (Diptera: Ceratopogonidae) and of potential novel vectors, Culicoides pulicaris Linnaeus, Culicoides obsoletus group Meigen and Culicoides newsteadi Austen. The models containing the ,best' climatic predictors of distribution for each species, were selected from combinations of 40 temporally Fourier-processed remotely sensed variables and altitude at a 1 km spatial resolution using discriminant analysis. Kappa values of around 0.6 for all species models indicated substantial levels of agreement between model predictions and observed data. Whilst the distributions of C. obsoletus group and C. newsteadi were predicted by temperature variables, those of C. pulicaris and C. imicola were determined mainly by normalized difference vegetation index (NDVI), a variable correlated with soil moisture and vegetation biomass and productivity. These models were used to predict species presence in unsampled pixels across Italy and for C. imicola across Europe and North Africa. The predicted continuous presence of C. pulicaris along the appenine mountains, from north to south Italy, suggests BTV transmission may be possible in a large proportion of this region and that seasonal transhumance (seasonal movement of livestock between upland and lowland pastures) even in C. imicola -free areas should not generally be considered safe. The predicted distribution of C. imicola distribution shows substantial agreement with observed surveillance data from Greece and Iberia (including the Balearics) and parts of mainland Italy (Lazio, Tuscany and areas of the Ionian coast) but is generally much more restricted than the observed distribution (in Sardinia, Corsica and Morocco). The low number of presence sites for C. imicola in Sicily meant that only a restricted range of potential C. imicola habitats were included in the training set and that predictions could only be made within this range. Future modelling exercises will use abundance data collected according to a standardized protocol across the Mediterranean and, for Sicily in particular, should include non-climatic environmental variables that may influence breeding site suitability such as soil type. [source]


Prospective blinded comparison of surface versus wire electromyographic analysis of muscle recruitment in shoulder instability

PHYSIOTHERAPY RESEARCH INTERNATIONAL, Issue 1 2009
Anju Jaggi
Abstract Background.,This pilot study assesses level of agreement between surface and fine-wire electromyography (EMG), in order to establish if surface is as reliable as fine wire in the diagnosis and treatment of abnormal muscle patterning in the shoulder.,Method.,Eighteen participants (11 female) with unstable shoulders were recruited after written consent and ethical approval. Anthropometric information and mean skinfold size for triceps, subscapular, biceps and suprailiac sites were obtained. Triple-stud self-adhesive surface electrodes ('Triode'; Thermo Scientific, Physio Med Services, Glossop, Derbyshire, England) were placed over pectoralis major (PM), latissimus dorsi (LD), anterior deltoid (AD) and infraspinatus (IS) at standardized locations. Participants performed five identical uniplanar standard movements (flexion, abduction, external rotation, extension and cross-body adduction). After a 20-minute rest period, a dual-needle technique for fine-wire insertion was performed and the standard movements were repeated. An experienced examiner in each technique reported if muscle activation patterns differed from agreed normal during any movement and were blinded to the other test results. Sensitivity, specificity and Kappa values for level of agreement between methods were calculated for each muscle according to the method of Altman (1991).,Results.,Fifteen participants were successfully tested. Sensitivity, specificity and Kappa values between techniques for each muscle were PM (57%, 50%, 0.07), LD (38%, 85%, 0.22), AD (0%, 76%, ,0.19) and IS (85%, 75%, 0.6). Only IS demonstrated high sensitivity and specificity and a moderate level of agreement between the two techniques. There was no correlation between skinfold size and agreement levels.,Conclusion.,The use of surface EMG may help to classify types of shoulder instability and recognize abnormal muscle patterns. It may allow physiotherapists to direct specific rehabilitation strategies, avoiding strengthening of inappropriate muscles. It has a reasonable degree of confidence to evaluate IS but may have poor sensitivity in detecting abnormal patterns in PM, LD and AD. Further work is required to see if investigator interpretation may have been a factor for the poor level of agreement. Copyright © 2008 John Wiley & Sons, Ltd. [source]


Reliability and validity of Japanese version of the Mini-International Neuropsychiatric Interview

PSYCHIATRY AND CLINICAL NEUROSCIENCES, Issue 5 2005
TEMPEI OTSUBO md
Abstract The Mini-International Neuropsychiatric Interview (MINI) is a short, structured diagnostic interview used as a tool to diagnose 16 axis I (Diagnostic and Statistical Manual) DSM-IV disorders and one personality disorder. Its original version was developed by Sheehan and Lecrubier. We translated the MINI into Japanese, and investigated the reliability and validity of the Japanese version of MINI. Eighty-two subjects participated in the validation of the MINI versus the Structured Clinical Interview for DSM-III-R (SCID-P). One hundred and sixty-nine subjects participated in the validation of the MINI versus an expert's professional opinion. Seventy-seven subjects were interviewed by two investigators and subsequently readministered by a third interviewer blind to the results of initial evaluation 1,2 days later. In general, kappa values indicated good or excellent agreement between MINI and SCID-P diagnoses. Kappa values indicated poor agreement between MINI and expert's diagnoses for most diagnoses. Interrater and test,retest reliabilities were good or excellent. The mean durations of the interview were 18.8 min for MINI and 45.4 min for corresponding sections of SCID-P. Overall, the results suggest that the MINI Japanese version succeeds in reliably and validly eliciting symptom criteria used in making DSM-III-R diagnoses, and can be performed in less than half the time required for the SCID-P. [source]


How reliable is contact endoscopy of the nasopharynx in patients with nasopharyngeal cancer?

THE LARYNGOSCOPE, Issue 3 2009
Martin Wai Pak FRCS Ed (ORL)
Abstract Objectives/Hypothesis: To evaluate diagnostic reliability of contact rhinoscopy in patients with nasopharyngeal carcinoma. Study Design: A cross-sectional randomized single-blinded study was carried out to evaluate the reliability of the findings of contact rhinoscopy in patients with nasopharyngeal carcinoma assessed by different observers. Methods: Random images of contact endoscopy of 157 subjects including normal patients and patients with nasopharyngeal carcinoma, both prior to external beam radiation therapy (RT), the non-RT group, and after external beam radiation therapy, the post-RT group, were available for analysis. Three independent observers of varying clinical experience and histopathologic knowledge viewed the images and made a diagnosis for each image. The diagnosis of each image was correlated with the histology of the biopsy from the corresponding patient. Results: In the non-RT group, Kappa values for inter- and intraobserver reliability to differentiate normal epithelium from primary nasopharyngeal carcinoma were 0.894, 1.000, 0.794 and 0.694, 1.000, 0.776 for the house officer, radiologist, and pathologist, respectively. There were no significant differences in interobserver and intraobserver reliabilities between the assessors. In the post-RT group, Kappa values for the inter- and intraobserver reliability to diagnose recurrent carcinoma or atypia, squamous metaplasia, and radiation change for the three observers were 0.820, 0.718, 0.775 and 0.731, 0.622, 0.734, respectively. There were no significant differences in interobserver and intraobserver reliabilities between the assessors. Conclusions: The clinical diagnosis of nasopharyngeal carcinoma by contact endoscopy is highly reliable and is not dependent on the clinical experience or knowledge of histopathology of the observers. Laryngoscope, 119:523,527, 2009 [source]


Development and validation of a questionnaire for the assessment of bowel and lower urinary tract symptoms in women

BJOG : AN INTERNATIONAL JOURNAL OF OBSTETRICS & GYNAECOLOGY, Issue 4 2002
L. Hiller
Objective To develop a simple but sensitive instrument to evaluate and document symptoms of both bowel and urinary dysfunction in women. Design A 22-item questionnaire covering a range of bowel and urinary symptoms was developed and underwent rigorous psychometric testing. Setting The gynaecology departments of three hospitals, a urogynaecology clinic, a functional bowel clinic and a general practice. Population Six hundred and thirty women, comprising four groups: 1. women awaiting hysterectomy (n= 379), 2. women following hysterectomy (n= 45), 3. women referred with functional bowel and/or urinary symptoms (n= 65), 4. asymptomatic controls (n= 141). Main outcome measures The content, construct and criterion validity, internal consistency, reliability and responsiveness of the questionnaire were measured. Results Peer and patient reports and missing data patterns supported face and content validity. Factor analysis showed a clinically relevant four-factor structure with low content replication able to distinguish between patient groups, indicating good internal structure. Comparison with clinical, anorectal physiological, videoproctographic, transit time and urodynamic test results provide provisional indication of criterion validity. Key domain question analysis and Cronbach's alphas showed internal consistency. Kappa values demonstrated good test,retest reliability and key question correlation over time proved responsiveness. Conclusions Our findings support the suitability, clinical validity, reliability and responsiveness of a simple questionnaire, which is sensitive to the constraints of clinical practice. The authors recommend its use in health care evaluation research assessing the effects of pelvic surgery and as a useful tool in comparing treatment efficacy. [source]


Children are reliable reporters of common symptoms: results from a self-reported symptom diary for primary school children

ACTA PAEDIATRICA, Issue 7 2010
C Lundqvist
Abstract Background:, Collecting information on subjective symptoms in children by parental reports or physician's interview is indirect and not suited for prospective data collection over extended time periods. Aim:, To examine the reliability of a diary for symptom self-reports by primary school children. Methods:, Children aged 7,8 or 11,12 were recruited from primary school and a paediatric outpatient department. A picture-based symptom diary was completed individually. Children were asked about presence of 10 specified subjective symptoms for five time periods covering the previous 24 h. The diary was completed twice for test,retest and answers were compared with semi structured physician's interviews. Results:, Test,retest reliability for reporting a symptom during the previous 24 h gave reliable kappa values of 0.64,0.91. Comparison with physician's interview gave kappas of 0.18,0.68. Requiring correct time of day for each symptom reduced reliability and validity. Kappa values for test,retest and child-physician agreement for the individual symptoms were respectively: sneezing, 0.80 and 0.30; sore throat, 0.89, 0.30; tiredness, 0.88, 0.65; headache, 0.64, 0.66; runny nose, 0.91, 0.68; sore eyes, 0.67, 0.18; cough, 0.73, 0.58; stomach ache, 0.69, 0.45. Conclusion:, Our symptom diary gives reliable self-report data from primary school children. It may be used for prospective symptom monitoring. [source]


Methods for detecting age-related maculopathy: a comparison between photographic and clinical assessment

CLINICAL & EXPERIMENTAL OPHTHALMOLOGY, Issue 5 2000
Gabriella Tikellis GradDip
ABSTRACT Purpose: To examine the sensitivity, specificity and overall agreement between photographic and clinical assessment in detecting age-related maculopathy (ARM) features in the context of an epidemiological study, the Vitamin E, Cataract and Age-related Maculopathy Study (VECAT). Methods: A total of 1204 volunteers aged between 55 and 80 years of age, who were enrolled in the VECAT Study, had both slit-lamp biomicroscopy examination and fundus photos taken as part of the baseline ophthalmic examination. The Nidek 3-DX fundus camera (Nidek, Gamagori, Japan) was used to produce paired, one-framed, coloured, 15° stereoslides of the macular area at a fixed angle. An International Classification and Grading System for Age-related Maculopathy and Age-related Macular Degeneration was used to grade the stereoslides. Agreement in the detection of drusen, pigment abnormalities, and late stage ARM features was assessed using unweighted kappa statistic. Cases of disagreement were verified using clinical data records, grading documentation and the review of stereoslides. Results: Macula status was available for 2386 eyes. For drusen of size < 63 ,m, sensitivity was 47%, specificity was 68% with a kappa value of 0.20. For drusen , 125 ,m, sensitivity and specificity were , 81%. Kappa values ranged from 0.56 to 0.71. Levels of agreement for pigment abnormalities and late ARM were in the substantial range (i.e. kappa values from 0.70 to 1.00). Conclusions: Slit-lamp biomicroscopy was found to be comparable to photograding (using the Nidek 3-DX fundus camera) for detecting features pertaining to ARM. However, given the objectivity and permanency of stereoslides, photograding is still the more reliable and the preferred system of assessing ARM in the context of an epidemiological study. [source]


Fred Hollows lecture: Digital screening for eye disease

CLINICAL & EXPERIMENTAL OPHTHALMOLOGY, Issue 3 2000
Ij Constable
ABSTRACT The purpose of this study was to explore progress, in the adaptation to community screening for blinding eye disease, of digital imaging devices and technology for storage and transmission. Available imaging systems were compared to gold standard clinical photography in terms of sensitivity and specificity for diagnosis of common blinding eye conditions. Since the use of expensive non-portable imaging devices is likely to be limited for widespread community screening purposes, a portable fundus camera (Nidek, Chiyoda-ku, Japan) and a prototype monocular digital indirect ophthalmoscope constructed at the Lions Eye Institute (LEI) were selected for comparative trials for the screening of optic disc cupping, glaucoma and clinical signs of diabetic retinopathy. Fifty-one eyes of 27 consecutive patients being assessed at the LEI clinic for glaucoma were dilated and photographed with a Zeiss retinal camera, and digital images were taken with the portable Nidek NM100 fundus camera (Carl Zeiss, Oberkochen, Germany) or with a prototype digital monocular indirect ophthalmoscope. Vertical cup : disc ratios (VCDR) were measured on the disc photographs by one ophthalmologist while three other clinicians were presented with compressed digital images in random order to estimate VCDR. Field trials were also carried out to demonstrate the practicality of compression, local storage and then transmission by mobile telephone ISDN lines and satellite, of optic discs and fundus images of patients with diabetes in either rural Western Australia or Surabaya, Indonesia. Kappa values of correlations of measurement of agreement between measured and estimated VCDR were 0.87, 0.45 and 0.84, respectively, for the three observers, corresponding to a specificity of 79,97% and a sensitivity of 70,95%. The portable Nidek fundus camera was also assessed for specificity and sensitivity in the diagnosis of diabetic retinopathy in comparison to standard Zeiss fundus camera photographs. Of 49 eyes in 25 consecutive patients attending the LEI clinic for assessment of diabetic retinopathy, three ophthalmologists assessed photographs and images in random order. When used for screening diabetic retinopathy, the digital images of the Nidek camera were graded as adequate quality in only 56% of eyes compared to 93% of the photographs. The kappa value of agreement in analysis of diabetic retinopathy was only 0.30. The prototype digital monocular indirect ophthalmoscope compared favourably with the Nidek camera. At 1:5 compression, images of size 36 kB transmitted from Surabaya to Perth took 29 s on the mobile telephone, while uncompressed images took 170 s. Images compressed 1:5 were transmitted in 60 s using the satellite telephone, while the uncompressed images took 240 s. Satellite transmission was more expensive but the lines were more stable than telephone connections from Indonesia. Digital imaging is becoming a powerful tool for ophthalmology in clinical records, teaching and research, and interoffice diagnostic opinions. It also has enormous potential for community screening for blinding eye diseases, such as glaucoma and diabetic retinopathy. Inexpensive portable imaging devices that are easy to use, and on which local health workers might be trained, must be developed and validated in terms of sensitivity and specificity of performance. The technology of image capture, image compression, transmission, data base storage and analysis is rapidly evolving and becoming less expensive. [source]


A standardized photographic method for evaluating enamel opacities including fluorosis

COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, Issue 2004
Judith A. Cochran
Abstract,-,Objectives: The objective of this study was to demonstrate the reproducibility of a standardized photographic technique for recording fluorosis when used by a group of epidemiologists as part of a large multicentred European study. Methods: Studies were first carried out to develop the equipment specification and photographic method. The author (JAC) was then trained and calibrated in this method. She was then responsible for the training and calibration of examiners from a further six European study sites. The method involved taking two transparencies of the permanent maxillary central incisors of 8-year-old children, the first after 8 s while the teeth were still wet and the second after 105 s when the teeth had been allowed to dry out naturally. Data were collected at a central location during a training/calibration exercise and subsequently, during the conduct of a large study to measure fluorosis prevalence, at the seven sites. Intra- and interexaminer reproducibility of the photographic method were measured by grading the transparencies produced by all the examiners according to the DDE and TF indices. Results: The time period in which the transparencies were taken was to within 4 s among the examiners. Transparencies scored according to the TF index gave a range of Kappa values of 0.45-0.66 for intraexaminer reliability and 0.32-0.55 for interexaminer reliability. When using the DDE index Kappa values ranged from 0.43 to 0.70 for intraexaminer reliability and from 0.34 to 0.69 for interexaminer reliability. Conclusion: The photographic method was mostly robust and reproducible when used by epidemiologists from seven European study sites. [source]


Validation of the Mayo Dysphagia Questionnaire

DISEASES OF THE ESOPHAGUS, Issue 3 2007
A. B. M. Grudell
SUMMARY., While multiple instruments characterize upper gastrointestinal symptoms, a validated instrument devoted to the measurement of a spectrum of esophageal dysphagia attributes is not available. Therefore, we constructed and validated the Mayo Dysphagia Questionnaire (MDQ). The 27 items of the MDQ underwent content validity, feasibility, concurrent validity, reproducibility, internal consistency, and construct validity testing. To assess content validity, five esophageal subspecialty gastroenterologists reviewed the items to ensure inclusion of pertinent domains. Feasibility testing was done with eight outpatients who refined problematic items. To assess concurrent validity, 70 patient responses on the MDQ were compared to responses gathered in a structured patient-physician interview. A separate group of 70 outpatients completed the MDQ twice to assess the reproducibility of each item. A total of 148 patients participated in the validation process (78 [53%] men; mean age 62). On average, the MDQ took 6 minutes to complete. A single item (odynophagia) tested poorly with a kappa value of < 0.4. Otherwise, the majority of concurrent validity kappa values were in the good to excellent range with a mean of 0.63 (95% CI 0.22,0.89). The majority of reproducibility kappa values were also in the good to excellent range with a median kappa value of 0.76 (interquartile range: 0.67,0.81). Cronbach's alpha values were excellent in the range of 0.86,0.88. Spearman rank correlation coefficients to assess construct validity were also excellent in the range of 0.87,0.98. Thus, the MDQ is a concise instrument that demonstrates overall excellent concurrent validity, reproducibility, internal consistency, and construct validity for the features of esophageal dysphagia. [source]


Report: Dermoscopy as a diagnostic tool in demodicidosis

INTERNATIONAL JOURNAL OF DERMATOLOGY, Issue 9 2010
Rina Segal MD
Background, The in vivo demonstration of Demodex infestation is traditionally based on the microscopic identification of Demodex mites, which is time consuming and requires specific equipment and a trained observer. Objective, The aim of this study was to describe for the first time the use of polarized-light dermoscopy for the diagnosis of demodicidosis in patients with variable clinical presentations. Methods, A total of 72 patients with variable facial eruptions were examined clinically, microscopically, and dermoscopically for the presence of Demodex mites. Results, Of the 72 patients, 55 were found to have demodicidosis. In 54 patients, the dermoscopy examination yielded a specific picture consisting of Demodex "tails" and Demodex follicular openings. In patients with an inflammatory variant of demodicidosis, reticular horizontal dilated blood vessels were also visualized. Microscopically, skin scrapings demonstrated Demodex in 52 patients. Overall, the dermoscopy findings showed excellent agreement with the microscopy findings (kappa value 0.86, 95% CI 0.72,0.99, P < 0.001). In the remaining 17 patients, there was no evidence of Demodex infestation either microscopically or dermoscopically. Limitations, The study was not blinded. As there are no standards for the diagnosis of demodicidosis, our results were based on criteria developed by our research group. Conclusions, This is the first description of the specific dermoscopic findings associated with variable clinical presentations of demodicidosis. Dermoscopy may serve as a valuable tool for the real-time validation of Demodex infestation and the evaluation and follow-up of affected patients. [source]


The Role of Benzodiazepines in the Treatment of Insomnia

JOURNAL OF AMERICAN GERIATRICS SOCIETY, Issue 6 2001
Meta-Analysis of Benzodiazepine Use in the Treatment of Insomnia
PURPOSE: To obtain a precise estimate of the efficacy and common adverse effects of benzodiazepines for the treatment of insomnia compared with those of placebo and other treatments. BACKGROUND: Insomnia, also referred to as disorder of initiating or maintaining sleep, is a common problem and its prevalence among older people is estimated to be 23% to 34%.1 The total direct cost in the United States for insomnia in 1995 was estimated to be $13.9 billion.2 The complaint of insomnia in older people is associated with chronic medical conditions; psychiatric problems, mainly depression, chronic pain, and poor perceived general condition;1,3,4 and use of sleep medications.5 Thus in most cases, insomnia is due to some other underlying problem and is not just a consequence of aging.6 Accordingly, the management of insomnia should focus on addressing the primary problem and not just short-term treatment of the insomnia. Benzodiazepines belong to the drug class of choice for the symptomatic treatment of primary insomnia.7 This abstract will appraise a meta-analysis that compared the effect of benzodiazepines for short-term treatment of primary insomnia with placebo or other treatment. DATA SOURCES: Data sources included articles listed in Medline from 1966 to December 1998 and the Cochrane Controlled Trials Registry. The medical subject heading (MeSH) search terms used were "benzodiazepine" (exploded) or "benzodiazepine tranquillizers" (exploded) or "clonazepam,""drug therapy,""randomized controlled trial" or "random allocation" or "all random,""human," and "English language." In addition, bibliographies of retrieved articles were scanned for additional articles and manufacturers of brand-name benzodiazepines were asked for reports of early trials not published in the literature. STUDY SELECTION CRITERIA: Reports of randomized controlled trials of benzodiazepine therapy for primary insomnia were considered for the meta-analysis if they compared a benzodiazepine with a placebo or an alternative active drug. DATA EXTRACTION: Data were abstracted from 45 randomized controlled trials representing 2,672 patients, 47% of whom were women. Fifteen studies included patients age 65 and older and four studies involved exclusively older patients. Twenty-five studies were based in the community and nine involved inpatients. The duration of the studies ranged from 1 day to 6 weeks, with a mean of 12.2 days and median of 7.5 days. The primary outcome measures analyzed were sleep latency and total sleep duration after a sleep study, subjects' estimates of sleep latency and sleep duration, and subjects' report of adverse effects. Interrater reliability was checked through duplicate, independent abstraction of the first 21 articles. Overall agreement was between 95% and 98% (kappa value of 0.90 and 0.95 accordingly) for classification of the studies and validity of therapy, and 76% (kappa value of 0.51) for study of harmful effects. A scale of 0 to 5 was used to rate the individual reports, taking into account the quality of randomization, blinding, follow-up, and control for baseline differences between groups. Tests for homogeneity were applied across the individual studies and, when studies were found to be heterogeneous, subgroup analysis according to a predefined group was performed. MAIN RESULTS: The drugs used in the meta-analysis included triazolam in 16 studies; flurazepam in 14 studies; temazepam in 13 studies; midazolam in five studies; nitrazepam in four studies; and estazolam, lorazepam, and diazepam in two studies each. Alternative drug therapies included zopiclone in 13 studies and diphenhydramine, glutethimide, and promethazine in one study each. Only one article reported on a nonpharmacological treatment (behavioral therapy). The mean age of patients was reported in 33 of the 45 studies and ranged between 29 and 82. SLEEP LATENCY: In four studies involving 159 subjects, there was sleep-record latency (time to fall asleep) data for analysis. The pooled difference indicated that the latency to sleep for patients receiving a benzodiazepine was 4.2 minutes (95% CI = (,0.7) (,9.2)) shorter than for those receiving placebo. Patient's estimates of sleep latency examined in eight studies showed a difference of 14.3 minutes (95% CI = 10.6,18.0) in favor of benzodiazepines over placebo. TOTAL SLEEP DURATION: Analysis of two studies involving 35 patients in which total sleep duration using sleep-record results was compared indicated that patients in the benzodiazepine groups slept for an average of 61.8 minutes (95% CI = 37.4,86.2) longer than those in the placebo groups. Patient's estimates of sleep duration from eight studies (566 points) showed total sleep duration to be 48.4 minutes (95% CI = 39.6,57.1) longer for patients taking benzodiazepines than for those on placebo. ADVERSE EFFECTS: Analysis of eight studies (889 subjects) showed that those in the benzodiazepine groups were more likely than those in the placebo groups to complain of daytime drowsiness (odds ratio (OR) 2.4, 95% confidence interval (CI) = 1.8,3.4). Analysis of four studies (326 subjects) also showed that subjects in the benzodiazepine groups were more likely to complain of dizziness or lightheadedness than the placebo groups. (OR 2.6, 95% CI = 0.7,10.3). Despite the increased reported side effects in the benzodiazepine groups, drop-out rates were similar in the benzodiazepine and placebo groups. For patient reported outcome, there was no strong correlation found for sleep latency data, (r = 0.4, 95% CI = (,0.3) (,0.9)) or for sleep duration (r = 0.2, 95% CI = ,0.8,0.4) between benzodiazepine dose and outcome. COMPARISON WITH OTHER DRUGS AND TREATMENTS: In three trials with 96 subjects, meta-analysis of the results comparing benzodiazepines with zopiclone, did not show significant difference in sleep latency in the benzodiazepine and placebo groups, but the benzodiazepine groups had increased total sleep duration (23.1 min. 95% CI = 5.6,40.6). In four trials with 252 subjects, the side effect profile did not show a statistically significant difference (OR 1.5, CI 0.8,2.9). There was only one study comparing the effect of behavioral therapy with triazolam. The result showed that triazolam was more effective than behavioral therapy in decreasing sleep latency, but its efficacy declined by the second week of treatment. Behavioral therapy remained effective throughout the 9-week follow-up period. There were four small trials that involved older patients exclusively, with three of the studies having less than 2 weeks of follow-up. The results were mixed regarding benefits and adverse effects were poorly reported. CONCLUSION: The result of the meta-analysis shows that the use of benzodiazepines results in a decrease in sleep latency and a significant increase in total sleep time as compared with placebo. There was also a report of significantly increased side effects, but this did not result in increased discontinuation rate. There was no dose-response relationship for beneficial effect seen with the use of benzodiazepines, although the data are scant. Zopiclone was the only alternative pharmacological therapy that could be studied with any precision. There was no significant difference in the outcome when benzodiazepines were compared with zopiclone. There was only one study that compared the effect of benzodiazepines with nonpharmacological therapy; thus available data are insufficient to comment. [source]


The use of the comprehensive International Classification of Functioning, Disability and Health Core Set for low back pain in clinical practice: a reliability study

PHYSIOTHERAPY RESEARCH INTERNATIONAL, Issue 3 2009
Roger Hilfiker
Abstract Background and Purpose.,The comprehensive International Classification of Functioning, Disability and Health (ICF) Core Set for low back pain (LBP) can be used to describe functioning and the influence of the environment of patients with LBP with a selection of 78 categories, from the ICF components ,body functions', ,body structures', ,activities and participation' and ,environmental factors'. The reliability of the qualifiers' scale of the ICF Core Set for LBP has not yet been studied.,Methods.,Reliability study was conducted in three study centres in the German-speaking part of Switzerland. In the first step, two physiotherapists independently assessed 31 patients with LBP with the original qualifier scale of the 78 ICF categories from the comprehensive ICF Core Set for LBP. After the first 31 patients, inter-rater reliability was assessed and the response options were reduced based on a Rasch analysis. The second sample (n = 30) was assessed by the physiotherapists with the modified qualifier scale and inter-rater reliability was calculated again.,Results.,The percentage agreement for the ICF categories ranged from 19% to 87%, mean 44% (nominal kappa from ,0.73 to 0.54, median 0.22; weighted kappa ,0.2 to 0.69, median 0.38) in the first round with the original qualifier scale. In the second round with the reduced response options, the percentage agreement ranged from 23% to 90%, mean 49% (nominal kappa from ,0.15 to 0.71, median 0.24; weighted kappa ,0.16 to 0.81, median 0.25). The overall percentage agreement was 44% in the first round and 49% with the reduced response categories. The overall kappa value in the first round was 0.29 and in the second round 0.32. There was a small but statistically significant improvement in the agreement.,Conclusion.,The low-to-moderate reliability found in this study requires an improved operationalization (e.g. the definition and description of each response category) and improved instructions for the ICF Core Set for LBP. Copyright © 2009 John Wiley & Sons, Ltd. [source]


Lack of agreement between rheumatologists in defining digital ulceration in systemic sclerosis

ARTHRITIS & RHEUMATISM, Issue 3 2009
Ariane L. Herrick
Objective To test the intra- and interobserver variability, among clinicians with an interest in systemic sclerosis (SSc), in defining digital ulcers. Methods Thirty-five images of finger lesions, incorporating a wide range of abnormalities at different sites, were duplicated, yielding a data set of 70 images. Physicians with an interest in SSc were invited to take part in the Web-based study, which involved looking through the images in a random sequence. The sequence differed for individual participants and prevented cross-checking with previous images. Participants were asked to grade each image as depicting "ulcer" or "no ulcer," and if "ulcer," then either "inactive" or "active." Images of a range of exemplar lesions were available for reference purposes while participants viewed the test images. Intrarater reliability was assessed using a weighted kappa coefficient with quadratic weights. Interrater reliability was estimated using a multirater weighted kappa coefficient. Results Fifty individuals (most of them rheumatologists) from 15 countries participated in the study. There was a high level of intrarater reliability, with a mean weighted kappa value of 0.81 (95% confidence interval [95% CI] 0.77, 0.84). Interrater reliability was poorer (weighted , = 0.46 [95% CI 0.35, 0.57]). Conclusion The poor interrater reliability suggests that if digital ulceration is to be used as an end point in multicenter clinical trials of SSc, then strict definitions must be developed. The present investigation also demonstrates the feasibility of Web-based studies, for which large numbers of participants can be recruited over a short time frame. [source]


Methods for detecting age-related maculopathy: a comparison between photographic and clinical assessment

CLINICAL & EXPERIMENTAL OPHTHALMOLOGY, Issue 5 2000
Gabriella Tikellis GradDip
ABSTRACT Purpose: To examine the sensitivity, specificity and overall agreement between photographic and clinical assessment in detecting age-related maculopathy (ARM) features in the context of an epidemiological study, the Vitamin E, Cataract and Age-related Maculopathy Study (VECAT). Methods: A total of 1204 volunteers aged between 55 and 80 years of age, who were enrolled in the VECAT Study, had both slit-lamp biomicroscopy examination and fundus photos taken as part of the baseline ophthalmic examination. The Nidek 3-DX fundus camera (Nidek, Gamagori, Japan) was used to produce paired, one-framed, coloured, 15° stereoslides of the macular area at a fixed angle. An International Classification and Grading System for Age-related Maculopathy and Age-related Macular Degeneration was used to grade the stereoslides. Agreement in the detection of drusen, pigment abnormalities, and late stage ARM features was assessed using unweighted kappa statistic. Cases of disagreement were verified using clinical data records, grading documentation and the review of stereoslides. Results: Macula status was available for 2386 eyes. For drusen of size < 63 ,m, sensitivity was 47%, specificity was 68% with a kappa value of 0.20. For drusen , 125 ,m, sensitivity and specificity were , 81%. Kappa values ranged from 0.56 to 0.71. Levels of agreement for pigment abnormalities and late ARM were in the substantial range (i.e. kappa values from 0.70 to 1.00). Conclusions: Slit-lamp biomicroscopy was found to be comparable to photograding (using the Nidek 3-DX fundus camera) for detecting features pertaining to ARM. However, given the objectivity and permanency of stereoslides, photograding is still the more reliable and the preferred system of assessing ARM in the context of an epidemiological study. [source]


Quantification of upper extremity function and range of motion in children with cerebral palsy

DEVELOPMENTAL MEDICINE & CHILD NEUROLOGY, Issue 12 2008
L Andrew Koman MD
This study evaluated the hypothesis that upper extremity function and range of motion can be quantified reliably in children with cerebral palsy (CP) in a busy clinical setting. The specific aim was to determine the inter- and intrarater reliability of a modified House Functional Classification (MHC) system to evaluate upper extremity function and a standardized instrument to document upper extremity range of motion (Upper Extremity Rating Scale [UERS]). Sixty-five children with CP (43 males, 22 females, mean age 9y 2mo, SD 4y 1mo) with spasticity involving the upper extremity (quadriplegia n=22; hemiplegia n=36; diplegia n=7; Gross Motor Functional Classification System Levels I n=41, II n=6, III n=3, IV n=5, V n=10) were evaluated independently by occupational therapists and orthopedic surgeons using both instruments at several visits. Inter- and intrarater reliability were determined for both instruments by calculating measures of agreement (weighted kappa values and intraclass correlation coefficients [ICCs]). Interrater agreement (ICC=0.94) and intrarater agreement (ICC=0.96) on the MHC were good to excellent. Similarly, inter-rater agreement (kappa 0.66,0.81) and intrarater agreement (kappa 0.64,0.88) on the UERS was either good or excellent. The MHC and the UERS provide standardized, reliable, reproducible, and efficient instruments that can be used by occupational therapists and orthopedic surgeons to evaluate the upper extremities of children with CP. [source]


Assessment of specimen adequacy reproducibility: An Italian experience

DIAGNOSTIC CYTOPATHOLOGY, Issue 4 2003
Gioia Montanari M.D.
Abstract Interobserver disagreement on smear adequacy may influence the evaluation of the performance of samplers as well as Pap test sensitivity and follow-up. In 1998, the Italian Group for Cervical Cancer Screening (GISCi) promoted a study on the reproducibility of adequacy criteria using a modified version of the Bethesda system. A set of 200 smears was circulated among six Italian laboratories situated in different parts of the country. For each smear, participants were requested to provide a summary judgment on its adequacy and on the cause(s) of inadequacy, if any. Agreement was measured using kappa-type statistics. The agreement among laboratories was generally good. In comparisons, among five laboratories, kappa values ranged from 0.47 to 0.66. At the consensus meeting on 42 slides, on which at least 2 laboratories dissented from the majority, agreement was reached unanimously for 31 reviewed slides and among 5,6 centers for 11. In this article, some guidance is given in order to attribute to one of the two categories satisfactory/unsatisfactory those smears that have been traditionally considered as candidates for the category of "satisfactory but limited by ," (SBLB). New Italian guidelines on adequacy proposed the GISCi are presented and the recommendation is made to eliminate the SBLB category. Diagn. Cytopathol. 2003;28:224,226. © 2003 Wiley-Liss, Inc. [source]


Numerical modification of the Los Angeles classification of gastroesophageal reflux disease fails to decrease observer variation

DIGESTIVE ENDOSCOPY, Issue 1 2004
Motoyasu Kusano
Background:, We previously reported that a new endoscopic classification of gastroesophageal reflux disease, the Los Angeles classification, showed considerable observer variation depending on the experience of the endoscopist. In the present study, we evaluated some modifications of the classification to determine whether we could decrease observer variation. Methods:, Fifty endoscopic photographs, each showing four images of the squamo-columnar junction, were prospectively obtained from 50 consecutive patients with gastroesophageal reflux disease. Two groups of eight endoscopists divided by their endoscopic experience, group 1 (100,500 procedures) and group 2 (more than 500 procedures), assessed the photographs using classifications with the following modifications: (i) addition of grade O to describe healed mucosal breaks and setting grade B as more than 5 mm or 10 mm; or (ii) addition of grade O and setting grade D as 75,99% or 100% circumferential. Results:, Changing the definition of grade B or grade D did not increase the kappa values for either group of observers. Conclusions:, These modifications of the Los Angeles classification were unable to decrease observer variation. [source]


Validation of the Mayo Dysphagia Questionnaire

DISEASES OF THE ESOPHAGUS, Issue 3 2007
A. B. M. Grudell
SUMMARY., While multiple instruments characterize upper gastrointestinal symptoms, a validated instrument devoted to the measurement of a spectrum of esophageal dysphagia attributes is not available. Therefore, we constructed and validated the Mayo Dysphagia Questionnaire (MDQ). The 27 items of the MDQ underwent content validity, feasibility, concurrent validity, reproducibility, internal consistency, and construct validity testing. To assess content validity, five esophageal subspecialty gastroenterologists reviewed the items to ensure inclusion of pertinent domains. Feasibility testing was done with eight outpatients who refined problematic items. To assess concurrent validity, 70 patient responses on the MDQ were compared to responses gathered in a structured patient-physician interview. A separate group of 70 outpatients completed the MDQ twice to assess the reproducibility of each item. A total of 148 patients participated in the validation process (78 [53%] men; mean age 62). On average, the MDQ took 6 minutes to complete. A single item (odynophagia) tested poorly with a kappa value of < 0.4. Otherwise, the majority of concurrent validity kappa values were in the good to excellent range with a mean of 0.63 (95% CI 0.22,0.89). The majority of reproducibility kappa values were also in the good to excellent range with a median kappa value of 0.76 (interquartile range: 0.67,0.81). Cronbach's alpha values were excellent in the range of 0.86,0.88. Spearman rank correlation coefficients to assess construct validity were also excellent in the range of 0.87,0.98. Thus, the MDQ is a concise instrument that demonstrates overall excellent concurrent validity, reproducibility, internal consistency, and construct validity for the features of esophageal dysphagia. [source]


Specific Epileptic Syndromes Are Rare Even in Tertiary Epilepsy Centers: A Patient-oriented Approach to Epilepsy Classification

EPILEPSIA, Issue 3 2004
Christoph Kellinghaus
Summary: Purpose: To assess the practicability and reliability of a five-dimensional patient-oriented epilepsy classification and to compare it with the International League Against Epilepsy (ILAE) classification of epilepsy and epileptic syndromes. The dimensions consist of the epileptogenic zone, semiologic seizure type(s), etiology, related medical conditions, and seizure frequency. Methods: The 185 epilepsy patients (94 adults, 91 children, aged 18 years or younger) were randomly selected from the database of a tertiary epilepsy center and the general neurological department of a metropolitan hospital (28 adults). The charts were reviewed independently by two investigators and classified according to both the ILAE and the patient-oriented classification. Interrater reliability was assessed, and a final consensus among all investigators was established. Results: Only four (4%) adults and 19 (21%) children were diagnosed with a specific epilepsy syndrome of the ILAE classification. All other patients were in unspecific categories. The patient-oriented classification revealed that 64 adults and 56 children had focal epilepsy. In an additional 34 adults and 45 children, the epileptogenic zone could be localized to a certain brain region, and in 14 adults and five children, the epileptogenic zone could be lateralized. Fourteen adults and 21 children had generalized epilepsy. In 16 adults and 14 children, it remained unclear whether the epilepsy was focal or generalized. Generalized simple motor seizures were found in 66 adults and 52 children, representing the most frequent seizure type. Etiology could be determined in 40 adults and 45 children. Hippocampal sclerosis was the most frequent etiology in adults (10%), and cortical dysplasia (9%), in children. Seven adults and 31 children had at least daily seizures. Seventeen adults and 26 children had rare or no seizures at their last documented contact. The most frequent related medical conditions were psychiatric disorders and mental retardation. Interrater agreement was high (kappa values of 0.8 to 0.9) for both the patient-oriented and the ILAE classification. Conclusions: Specific epilepsy syndromes included in the current ILAE classification are rare even in a tertiary epilepsy center. Most patients are included in unspecific categories that provide only incomplete information. In contrast, all of the patients could be classified by the five-dimensional patient-oriented classification, providing all essential information for the management of the patients with a high degree of interrater reliability. [source]


Long-term reliability and observer comparisons in the radiographic diagnosis of periapical disease

INTERNATIONAL ENDODONTIC JOURNAL, Issue 2 2002
O. Molven
Abstract Aim The aim of this study was to evaluate and compare the long-term diagnostic consistency of two examiners, an endodontist and a radiologist, and to make comparisons with findings recorded by an observer with more recent scientific and clinical experience in endodontics. Methodology Three groups, each consisting of 20 full mouth series of intraoral radiographs, with 79, 93 and 85 endodontically-treated roots, respectively, were successively evaluated for periapical disease. Evaluations were at first performed separately by the three observers. Disagreement and difficult, borderline cases were subjected to joint evaluation. Intra- and interexaminer comparisons were made. For two of the observers the observations were compared with findings recorded several years before for the same cases in the same radiographs. Results The intra- and interobserver long-term reliability of the two original examiners resulted in 83% overall agreement, the kappa values were 0.54, 0.57 and 0.53. Comparisons between all three observers disclosed 82%, 85% and 86% agreement and kappa values 0.55, 0.58 and 0.60. The joint evaluations and decisions did not indicate a dominating influence from any of the observers. Conclusions The long-term reliability of the two original observers was judged as being satisfactory. All three observers judged the overall disease status of the material in the same way. The joint discussions of selected cases might reduce observer variation to an acceptable level, avoid a number of false recordings and increase the reliability and validity of the findings. [source]


Agreement between self-reported and pharmacy data on medication use in the Northern Finland 1966 Birth Cohort

INTERNATIONAL JOURNAL OF METHODS IN PSYCHIATRIC RESEARCH, Issue 2 2010
Marianne Haapea
Abstract Objective: To compare self-reported (SR) medication use and pharmacy data for major psychoactive medications and three classes of medications used for different indications, and to determine the socio-economic factors associated with the congruence. Methods: Postal questionnaire data collected in 1997 were compared with the register of the Social Insurance Institution of Finland on the reimbursed prescriptions purchased during 1997. Altogether 7625 subjects were included in this study. Drugs were categorized according to the Anatomical Therapeutic Chemical (ATC) system. Results: Kappa values were 0.77, 0.68, 0.84, 0.92 and 0.55 for antipsychotics, antidepressants, antiepileptics, antidiabetics and beta-blocking agents, respectively. Prevalence-adjusted and bias-adjusted kappa values were almost perfect (0.98,1.00). Reliability of antipsychotics use was better for married subjects than for those who were not married; and of antidepressants use for highly educated and married subjects than for those who were less educated and were not married. Altogether 414 (5.4%) responders and 285 (7.1%) non-responders had used at least one of the selected medications. Conclusion: Agreement between the SR and pharmacy data was moderate for psychoactive medication use. Even though data collected by postal questionnaire may underestimate the prevalence of medication use due to non-participation it can be assumed accurate enough for study purposes. Copyright © 2010 John Wiley & Sons, Ltd. [source]


Farmers' perceptions of soil erosion and its consequences in India's semiarid tropics

LAND DEGRADATION AND DEVELOPMENT, Issue 3 2005
J. Kerr
Abstract This paper investigates farmers' perceptions of soil erosion and how it affects crop yields, land values, and private conservation investments in India's semiarid tropics. It is based on three types of data: (1) a survey of farmers in three study villages; (2) a plot survey by a professional soil surveyor in the same villages; and (3) experimental and simulated data from nearby research stations with similar conditions. Farmers' perceptions of erosion are compared to the surveyor's using kappa, a statistical measure of interrater agreement. Perceived erosion,yield relationships are estimated econometrically and compared to experimental and simulated data. Effects on land values and conservation investments are estimated econometrically. Findings suggest that farmers are keenly aware of rill erosion but less aware of sheet erosion; kappa values ranging from 0 to 0·28 suggest low agreement with the soil surveyor. They anticipate annual yield losses of 5·8,11,per,cent due to rill erosion; these figures are reasonably consistent with those from nearby research stations. They anticipate yield increases of 3·8,14·5,per,cent due to installation of soil conservation bunds, largely because they can harvest soil from up the slope and capture organic matter. Perceived erosion has some effect on land values and soil conservation investments, but other factors such as irrigation and soil type have a much greater effect. These findings suggest that promoting soil conservation requires capitalizing on farmers' interest in short-term gains, such as from water and nutrient management. Copyright © 2005 John Wiley & Sons, Ltd. [source]


The effect of new diagnostic criteria for irritable bowel syndrome on community prevalence estimates

NEUROGASTROENTEROLOGY & MOTILITY, Issue 6 2003
Y. A. Saito
Abstract, The ,Rome' criteria for irritable bowel syndrome (IBS) have evolved over 15 years with four published versions. The impact of these changes on community prevalence rates is not known. Study aims were to estimate the prevalence of IBS using the four Rome criteria and agreement between Rome II and previous criteria. Questionnaires were mailed to a random sample of Olmsted County, Minnesota residents in 1992. Age- and gender-adjusted prevalence estimates were calculated for Rome II (1999), Rome I (1992), Rome (1990), and Rome (1989) criteria. Per cent agreement and kappa values were calculated to assess agreement. Of 892 eligible subjects, 643 (72%) responded. The age- and gender-adjusted prevalence of IBS was 5.1% [95% confidence interval (CI): 3.1, 7.0], 6.8% (95% CI: 4.7, 8.9), 5.1% (95% CI: 3.2, 7.1) and 27.6% (95% CI: 23.6, 31.5), respectively. In comparison with Rome II criteria, per cent agreement and , values were 97.2% and 0.78 (95% CI: 0.69, 0.88), 96.4% and 0.68 (95% CI: 0.55, 0.80), and 79.0% and 0.29 (95% CI: 0.19, 0.40), respectively. Thus, although differences were seen with the older criteria, compared with the Rome I criteria, good agreement was seen and community prevalence estimates were similar with the Rome II criteria. [source]


Clinical evaluation of pelvic floor muscle function in continent and incontinent women

NEUROUROLOGY AND URODYNAMICS, Issue 3 2004
Annemie Devreese
Abstract Aims The aim of the study was to investigate the reliability of a scoring system for the investigation of voluntary and reflex co-contractions of abdominal and pelvic floor muscles in lying, sitting, and standing positions in continent and incontinent women. Methods A visual inspection and digital (strength, tone, speed, and endurance) palpation scale was developed to measure the coordination of the lower abdominal and pelvic floor muscles. Inter-observer reliability of the scales was investigated in 40 continent and 40 incontinent women. Differences between the continent and incontinent group were analysed. Results Inter-observer reliability for the visual inspection scale showed kappa values between 0.91 and 1.00, for tone percentage of agreement ranged from 95 to 100% (superficial) and 95 to 98% (deep muscle). Weighted Kappa (Kw) varied from 0.77 to 0.95 for strength and 0.75 to 0.98 for the inward movement of superficial and deep pelvic floor muscles. Kw for coordination between the superficial and deep part of the pelvic floor muscles groups was from 0.87 to 0.88 and 0.97 to 1.00 for endurance and global speed of the pelvic floor contraction. The continent women exhibited significantly better coordination between the pelvic floor and lower abdominal muscles during coughing in all three positions. Also the superficial part of the inward movement, the feeling and the coordination of the pelvic floor muscles were significantly better in the continent group. Conclusions Visual inspection and digital tests are easy and reliable methods by which insight can be gained into the multi-muscular activity and coordination of the pelvic floor and lower abdominal muscles in continent and incontinent women. Neurourol. Urodynam. 23:190,197, 2004. © 2004 Wiley-Liss, Inc. [source]


Reliability and validity of Japanese version of the Mini-International Neuropsychiatric Interview

PSYCHIATRY AND CLINICAL NEUROSCIENCES, Issue 5 2005
TEMPEI OTSUBO md
Abstract The Mini-International Neuropsychiatric Interview (MINI) is a short, structured diagnostic interview used as a tool to diagnose 16 axis I (Diagnostic and Statistical Manual) DSM-IV disorders and one personality disorder. Its original version was developed by Sheehan and Lecrubier. We translated the MINI into Japanese, and investigated the reliability and validity of the Japanese version of MINI. Eighty-two subjects participated in the validation of the MINI versus the Structured Clinical Interview for DSM-III-R (SCID-P). One hundred and sixty-nine subjects participated in the validation of the MINI versus an expert's professional opinion. Seventy-seven subjects were interviewed by two investigators and subsequently readministered by a third interviewer blind to the results of initial evaluation 1,2 days later. In general, kappa values indicated good or excellent agreement between MINI and SCID-P diagnoses. Kappa values indicated poor agreement between MINI and expert's diagnoses for most diagnoses. Interrater and test,retest reliabilities were good or excellent. The mean durations of the interview were 18.8 min for MINI and 45.4 min for corresponding sections of SCID-P. Overall, the results suggest that the MINI Japanese version succeeds in reliably and validly eliciting symptom criteria used in making DSM-III-R diagnoses, and can be performed in less than half the time required for the SCID-P. [source]