Home About us Contact | |||
Interobserver Reliability (interobserver + reliability)
Selected AbstractsInterobserver Reliability of Video Recording in the Diagnosis of Nocturnal Frontal Lobe SeizuresEPILEPSIA, Issue 8 2007Luca Vignatelli Summary:,Background: Nocturnal frontal lobe seizures (NFLS) show one or all of the following semeiological patterns: (1) paroxysmal arousals (PA: brief and sudden recurrent motor paroxysmal behavior); (2) hyperkinetic seizures (HS: motor attacks with complex dyskinetic features); (3) asymmetric bilateral tonic seizures (ATS: motor attacks with dystonic features); (4) epileptic nocturnal wanderings (ENW: stereotyped, prolonged ambulatory behavior). Objective: To estimate the interobserver reliability (IR) of video-recording diagnosis in patients with suspected NFLS among sleep medicine experts, epileptologists, and trainees in sleep medicine. Methods: Sixty-six patients with suspected NFLS were included. All underwent nocturnal video-polysomnographic recording. Six doctors (three experts and three trainees) independently classified each case as "NFLS ascertained" (according to the above specified subtypes: PA, HS, ATS, ENW) or "NFLS excluded". IR was calculated by means of Kappa statistics, and interpreted according to the standard classification (0.0,0.20 = slight agreement; 0.21,0.40 = fair; 0.41,0.60 = moderate; 0.61,0.80 = substantial; 0.81,1.00 = almost perfect). Results: The observed raw agreement ranged from 63% to 79% between each pair of raters; the IR ranged from "moderate" (kappa = 0.50) to "substantial" (kappa = 0.72). A major source of variance was the disagreement in distinguishing between PA and nonepileptic arousals, without differences in the level of agreement between experts and trainees. Conclusions: Among sleep experts and trainees, IR of diagnosis of NFLS, based on videotaped observation of sleep phenomena, is not satisfactory. Explicit video-polysomnographic criteria for the classification of paroxysmal sleep motor phenomena are needed. [source] Interobserver reliability of visual interpretation of electroencephalograms in children with newly diagnosed seizuresDEVELOPMENTAL MEDICINE & CHILD NEUROLOGY, Issue 5 2006Hans Stroink MD The reliability of visual interpretation of electroencephalograms (EEG) is of great importance in assessing the value of this diagnostic tool. We prospectively obtained 50 standard EEGs and 61 EEGs after partial sleep deprivation from 93 children (56 males, 37 females) with a mean age of 6 years 10 months (SE 5mo; range 4mo,15y 7mo) with one or more newly diagnosed, unprovoked seizures. Two clinical neurophysiologists independently classified the background pattern and the presence of epileptiform discharges or focal non-epileptiform abnormalities of each EEG. The agreement was substantial for the interpretation of the EEG as normal or abnormal (kappa 0.66), almost perfect for the presence of epileptiform discharges (kappa 0.83), substantial for the occurrence of an abnormal background pattern (kappa 0.73), and moderate for the presence of focal non-epileptiform discharges (kappa 0.54). In conclusion, the reliability of the visual interpretation of EEGs in children is almost perfect as regards the presence of epileptiform abnormalities, and moderate to substantial for the presence of other abnormalities. [source] Interobserver agreement in the magnetic resonance location of cerebral vein and dural sinus thrombosisEUROPEAN JOURNAL OF NEUROLOGY, Issue 3 2007J. M. Ferro The interobserver variation in the magnetic resonance (MR) location of cerebral vein and dural sinus thrombosis (CVT) has not been previously reported. Four independent observers rated a convenience sample of 40 MR/MR angiographies to assess whether or not each dural sinus and major cerebral veins were occluded. Interobserver reliability was measured using , statistics. Interobserver agreement was comparable between the six pairs of raters. Agreement was excellent for thrombosis of the deep cerebral venous system (, = 1.00), cerebellar veins (, = 1.00), superior saggital sinus (, range: 0.82,1) and right jugular vein (, range: 0.84,0.95); good to excellent for the right transverse/sigmoid sinus (, range: 0.75,0.90) and the left jugular vein (, range: 0.65,0.85); moderate to excellent for the left lateral sinus (, range: 0.59,0.78) and the straight sinus (, range: 0.59,0.92); poor to good for the cortical veins (, range: 0.02,0.65). Agreement between observers varies with the location of CVT. It is good or excellent for most of the occluded sinus and veins, except for the cortical veins. This study suggests that information on the location of CVT can be reliably collected and used in multicentre studies. [source] A Randomized, Double-blind, Sham-controlled Trial Comparing Two Screening Devices for Radiation ContaminationACADEMIC EMERGENCY MEDICINE, Issue 9 2010Philip Salen MD Abstract Objectives:, This exploratory study compared the screening ability of a newly introduced radiation detection portal with a traditional Geiger counter for detection of radiation contamination in the setting of a mass casualty training exercise. Methods:, Following a pretrial evaluation of interobserver reliability for Geiger counter use, 30 volunteers were randomly assigned to don gowns containing three disks, each of which was either a sham resembling the radioactive samples or an actual cesium-137 sample; each subject participated a minimum of four times with different gowns each time. Each subject underwent standard radioactivity screening with the Geiger counter and the portal. Results:, Interobserver reliability was excellent between the two Geiger counter screeners in the pretrial exercise, correctly identifying 101 of 102 sham and radioactive samples (, = 0.98; 95% confidence interval [CI] = 0.94 to 1.00). For radioactively labeled subjects across all bodily locations, the portal (43/61, or 70.5%; 95% CI = 58.1% to 80.5%) was less sensitive than the Geiger counter screening (61/61, or 100%; 95% CI = 92.9% to 100%), which resulted in a portal false-negative rate of 29.5%. For radiation detection in the posterior thorax, the portal radiation screening (4/19, or 21.1%; 95% CI = 8% to 43.9%) was less accurate than the Geiger counter (19/19, or 100%; 95% CI 80.2% to 100%). In contrast, there were no major differences between the portal and the Geiger counter for radiation detection at the left shoulder, right shoulder, or sham (nonradiation) detection. There were no false-positive detections of the sham-labeled subjects for either device, yielding a specificity of 100% for both screening modalities. Conclusions:, Geiger counter screening was more sensitive than, and equally specific to, radiation detection portal screening in detecting radioactively labeled subjects during a radiation mass casualty drill. ACADEMIC EMERGENCY MEDICINE 2010; 17:1020,1023 © 2010 by the Society for Academic Emergency Medicine [source] Medico-legal assessment of disability in narcolepsy: an interobserver reliability studyJOURNAL OF SLEEP RESEARCH, Issue 1 2008FRANCESCA INGRAVALLO Summary Impairment because of narcolepsy strongly limits job performance, but there are no standard criteria to assess disability in people with narcolepsy and a scale of disease severity is still lacking. We explored: (1) the interobserver reliability among Italian Medical Commissions making disability and handicap benefit decisions for people with narcolepsy, searching for correlations between the recognized disability degree and patients' features; (2) the willingness to report patients to the driving licence authority and (3) possible sources of variance in judgement. Fifteen narcoleptic patients were examined by four Medical Commissions in simulated sessions. Raw agreement and interobserver reliability among Commissions were calculated for disability and handicap benefit decisions and for driving licence decisions. Levels of judgement differed on percentage of disability (P < 0.001), severity of handicap (P = 0.0007) and the need to inform the driving licence authority (P = 0.032). Interobserver reliability ranged from Kappa = ,0.10 to 0.35 for disability benefit decision and from Kappa = ,0.26 to 0.36 for handicap benefit decision. The raw agreement on driving licence decision ranged from 73% to 100% (Kappa not calculable). Spearman's correlation between percentages of disability and patients' features showed correlations with age, daytime naps, sleepiness, cataplexy and quality of life. This first interobserver reliability study on social benefit decisions for narcolepsy shows the difficulty of reaching an agreement in this field, mainly because of variance in interpretation of the assessment criteria. The minimum set of indicators of disease severity correlating with patients' self assessments encourages a disability classification of narcolepsy. [source] Digit ratios (2D:4D) determined by computer-assisted analysis are more reliable than those using physical measurements, photocopies, and printed scansAMERICAN JOURNAL OF HUMAN BIOLOGY, Issue 3 2009Heather C. Allaway Prenatal androgens influence the second to fourth digit ratio (2D:4D) of hands with men having lower ratios than women. Numerous methods are used to assess 2D:4D including, physical measurements with calipers, and measurements made from photocopies, scanned images, digital photographs, radiographs, and scaled tubes. Although each method appears relatively reliable, agreement upon a gold standard is necessary to better explore the putative effects of prenatal androgens. Our objective was to assess the level of intra and interobserver reliability when evaluating 2D:4D using four techniques: (1) physical measurements, (2) photocopies, (3) printed scanned images, and (4) computer-assisted image analysis. Physical measurements, photocopies, and printed scanned images were measured with Vernier calipers. Scanned images were also measured with computer-based calipers. Measurements were made in 30 men and 30 women at two different time points, by three experienced observers. Intraclass correlation coefficients were used to assess the level of reliability. Intraobserver reliability was best for computer-assisted (0.957), followed by photocopies (0.939), physical measurements (0.925), and printed scans (0.842; P = 0.015). Interobserver reliability was also greatest for computer-assisted (0.892), followed by photocopies (0.858), physical measurements (0.795), and printed scans (0.761; P = 0.001). Mean 2D:4D from physical measurements were higher than all other techniques (P < 0.0001). Digit ratios determined from computer-assisted, physical measurements, and printed scans were more reliable in men than women (P = 0.009, P = 0.017, and P = 0.012, respectively). In summary, 2D:4D determined from computer-assisted analysis yielded the most accurate and consistent measurements among observers. Investigations of 2D:4D should use computer-assisted measurements over alternate methods whenever possible. Am. J. Hum. Biol., 2009. © 2009 Wiley-Liss, Inc. [source] Interobserver reliability of the Nail Psoriasis Severity IndexCLINICAL & EXPERIMENTAL DERMATOLOGY, Issue 2 2007. Aktan Summary Background., Because the Psoriasis Area and Severity Index (PASI) does not consider the severity of nail disease, a scale that assesses the extent of involvement of psoriatic nails is needed. A new grading system, the Nail Psoriasis Severity Index (NAPSI) has been proposed. Aims., The purpose of this study was to assess the interobserver reliability of NAPSI. Methods., The nail features of 25 patients with psoriasis with nail involvement were evaluated and graded by three dermatologists for total NAPSI scores and nail scores. The quadrants of all nails were examined for the presence of matrix and bed features. Total NAPSI score (0,160) of patients and nail score (0,32) of the individual nails were calculated. Interobserver reliability assessments were performed by computing intraclass correlation coefficients (ICC; two-way mixed model, consistency definition). Results., The ICC(3,1) results for total NAPSI score and nail score were found to be 0.781 and 0.649, respectively. The ICC(3,1) for nail-bed and nail-matrix features were 0.869 and 0.584, respectively, in the total NAPSI scoring system, and 0.705 and 0.603, respectively, in the nail scoring system. Conclusion., Moderate to good agreement of scoring with the NAPSI was determined among the observers in this study. Our results suggest that scoring for nail-bed features seems to be more reliable than scoring for nail-matrix features. [source] The Bech,Rafaelsen Melancholia Scale (MES) in clinical trials of therapies in depressive disorders: a 20-year review of its use as outcome measureACTA PSYCHIATRICA SCANDINAVICA, Issue 4 2002P. Bech Bech P. The Bech,Rafaelsen Melancholia Scale (MES) in clinical trials of therapies in depressive disorders A 20-year review of its use as outcome measure. Acta Psychiatr Scand 2002: 106: 252,264. © Blackwell Munksgaard 2002. Objective:,To evaluate the psychometric properties of the Bech,Rafaelsen Melancholia Scale (MES) by reviewing clinical trials in which it has been used as outcome measure. Method:,The psychometric analysis included internal validity (total scores being a sufficient statistic), interobserver reliability, and external validity (responsiveness in short-term trials and relapse prevention in long-term trials). Results:,The results showed that the MES is a unidimensional scale, indicating that the total score is a sufficient statistic. The interobserver reliability of the MES has been found adequate both in unipolar and bipolar depression. External validity including both relapse, response and recurrence indicated that the MES has a high responsiveness and sensitivity. Conclusion:,The MES has been found a valid and reliable scale for the measurement of changes in depressive states during short-term as well as long-term treatment. [source] Interobserver agreement in neonatal seizure identificationEPILEPSIA, Issue 9 2009Aileen Malone Summary Objectives:, Accurate diagnosis of neonatal seizures is critically important and is often made clinically, without EEG (electroencephalography) monitoring. This observational study aimed to determine the accuracy and interobserver reliability of healthcare professionals in distinguishing clinically manifested seizures from other neonatal movements, when presented with clinical histories and digital video recordings only. Methods:, Twenty digital video recordings of paroxysmal movements in term and preterm infants were selected from a video-EEG database. The movements were categorized as seizure and nonseizure using EEG. Health care professionals (n = 137) from eight neonatal intensive care units (NICUs) were shown the video recordings with additional relevant clinical data, excluding EEG findings. The observers were asked to indicate which movements they considered to be seizure or nonseizure. A multirater Kappa statistic was used to assess agreement between observers and with the true diagnosis. Results:, Twenty video clips (11 seizure, 9 nonseizure) were evaluated by 91 doctors and 46 other professionals. The average number of correctly identified events was 10/20. Clonic seizures were correctly identified most frequently (range 36.5,95.6% of observers). Subtle seizures were poorly identified (range 20.4,49.6% of observers). The interobserver agreement (Kappa) for doctors and other health care professionals was poor at 0.21 and 0.29, respectively. Agreement with the correct diagnosis was also poor at 0.09 for doctors and ,0.02 for other healthcare professionals. Discussion:, It is often impossible to accurately differentiate between seizure-related and nonseizure movements in infants using clinical evaluation alone. In addition, doctors do not have a higher capacity for discriminating between neonatal paroxysmal events than other health care professionals. Until reliable continuous neurologic monitoring of newborn babies is available, it is likely that some babies with seizures will remain undetected and others with nonseizure movements will continue to be treated with potentially harmful anticonvulsants. [source] Interobserver Reliability of Video Recording in the Diagnosis of Nocturnal Frontal Lobe SeizuresEPILEPSIA, Issue 8 2007Luca Vignatelli Summary:,Background: Nocturnal frontal lobe seizures (NFLS) show one or all of the following semeiological patterns: (1) paroxysmal arousals (PA: brief and sudden recurrent motor paroxysmal behavior); (2) hyperkinetic seizures (HS: motor attacks with complex dyskinetic features); (3) asymmetric bilateral tonic seizures (ATS: motor attacks with dystonic features); (4) epileptic nocturnal wanderings (ENW: stereotyped, prolonged ambulatory behavior). Objective: To estimate the interobserver reliability (IR) of video-recording diagnosis in patients with suspected NFLS among sleep medicine experts, epileptologists, and trainees in sleep medicine. Methods: Sixty-six patients with suspected NFLS were included. All underwent nocturnal video-polysomnographic recording. Six doctors (three experts and three trainees) independently classified each case as "NFLS ascertained" (according to the above specified subtypes: PA, HS, ATS, ENW) or "NFLS excluded". IR was calculated by means of Kappa statistics, and interpreted according to the standard classification (0.0,0.20 = slight agreement; 0.21,0.40 = fair; 0.41,0.60 = moderate; 0.61,0.80 = substantial; 0.81,1.00 = almost perfect). Results: The observed raw agreement ranged from 63% to 79% between each pair of raters; the IR ranged from "moderate" (kappa = 0.50) to "substantial" (kappa = 0.72). A major source of variance was the disagreement in distinguishing between PA and nonepileptic arousals, without differences in the level of agreement between experts and trainees. Conclusions: Among sleep experts and trainees, IR of diagnosis of NFLS, based on videotaped observation of sleep phenomena, is not satisfactory. Explicit video-polysomnographic criteria for the classification of paroxysmal sleep motor phenomena are needed. [source] Doppler ultrasound assessment of posterior tibial artery size in humansJOURNAL OF CLINICAL ULTRASOUND, Issue 5 2006Manning J. Sabatier PhD Abstract Purpose. The difference between structural remodeling and changes in tone of peripheral arteries in the lower extremities has not been evaluated. The purpose of this study was to (1) evaluate the day-to-day reproducibility and interobserver reliability (IOR) of posterior tibial artery (PTA) diameter measurements and (2) evaluate the effect of posture on PTA diameter at rest (Drest), during 10 minutes of proximal cuff occlusion (Dmin), and after the release of cuff occlusion (Dmax), as well as range (Dmax , Dmin) and constriction [(Dmax , Drest)/(Dmax , Dmin) × 100] in vivo. Methods. We used B-mode sonography to image the PTA during each condition. Results. Day-to-day reliability was good for Drest (intraclass correlation coefficient [ICC] 0.95; mean difference 4.2%), Dmin (ICC 0.93; mean difference 5.4%), and Dmax (ICC 0.99; mean difference 2.2%). The coefficient of repeatability for IOR was 70.5 ,m, with a mean interobserver error of 4.7 ,m. The seated position decreased Drest (2.6 ± 0.2 to 2.4 ± 0.3 mm; p = 0.002), increased Dmin (2.1 ± 0.2 to 2.4 ± 0.2 mm; p = 0.001), and decreased Dmax (3.1 ± 0.4 to 2.8 ± 0.3 mm; p < 0.001) compared with the supine position. The seated position also decreased arterial range (Dmax , Dmin) from 0.9 ± 0.2 to 0.5 ± 0.1 mm (p = 0.003) and increased basal arterial constriction from 57 ± 19% to 105 ± 27% (p = 0.007). Conclusions. The system employed for measuring PTA diameter yields unbiased and consistent estimates. Furthermore, lower extremity arterial constriction and range change with posture in a manner consistent with known changes in autonomic activity. © 2006 Wiley Periodicals, Inc. J Clin Ultrasound 34:223,230, 2006 [source] In vitro analysis of the cement mantle of femoral hip implants: Development and validation of a CT-scan based measurement toolJOURNAL OF ORTHOPAEDIC RESEARCH, Issue 4 2005Thierry Scheerlinck Abstract We developed, validated and assessed inter- and intraobserver reliability of a CT-scan based measurement tool to evaluate morphological characteristics of the bone,cement,stem complex of hip implants in cadaver femurs. Two different models were investigated: the stem-cavity model using a double tapered polished femoral-stem that is removed after cement curing and the plastic-replica model using a stereolithographic stem replica that is left in place during CT-scanning. Software was developed to segment and analyze connective CT-images and identify the contours of bone, cement, and stem based on their respective gray values. Volume parameters (whole specimen, cement, stem, air contents of bone and cement), concentricity parameters (distances between centroids of stem and cement, cement and bone, stem and bone), contact surfaces (bone/air and cement/bone) and bone cement mantle thickness parameters were calculated. A three-dimensional protocol was developed to evaluate the minimal mantle thickness out of the CT-plane. The average accuracy for surfaces within CT-images was 7.47 mm2 (1.80%), for bone and cement mantle thickness it was 0.51 mm (9.39%), for distances between centroids it was 0.38 mm (18.5%) and contours: 0.27 mm (2.57%). The intra- and interobserver reliability of air content in bone and cement was sub-optimal (intraclass-correlation coefficient (JCC) as low as 0.54 with an average ICC of 0.85). All other variables were reliable (ICC > 0.81, average ICC: 0.96). This in vitro technique can assess characteristics of cement mantles produced by different cementing techniques, stem types or centralizers. © 2005 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved. [source] Validation of a dental image analyzer tool to measure alveolar bone loss in periodontitis patientsJOURNAL OF PERIODONTAL RESEARCH, Issue 1 2009W. J. Teeuw Background and Objective:, Radiographs are an essential adjunct to the clinical examination for periodontal diagnoses. Over the past few years, digital radiographs have become available for use in clinical practice. Therefore, the present study investigated whether measuring alveolar bone loss, using digital radiographs with a newly constructed dental image analyzer tool was comparable to the conventional method, using intra-oral radiographs on film, a light box and a Schei ruler. Material and Methods:, Alveolar bone loss of the mesial and distal sites of 60 randomly selected teeth from 12 patients with periodontitis was measured using the conventional method, and then using the dental image analyzer tool, by five dentists. The conventional method scored bone loss in categories of 10% increments relative to the total root length, whereas the software dental image analyzer tool calculated bone loss in 0.1% increments relative to the total root length after crucial landmarks were identified. Results:, Both methods showed a high interobserver reliability for bone loss measurements in nonmolar and molar sites (intraclass correlation coefficient , 0.88). Also, a high reliability between both methods was demonstrated (intraclass correlation coefficient nonmolar sites, 0.98; intraclass correlation coefficient molar sites, 0.95). In addition, the new dental image analyzer tool showed a high sensitivity (1.00) and a high specificity (0.91) in selecting teeth with , 50% or < 50% alveolar bone loss in comparison with the conventional method. Conclusion:, This study provides evidence that, if digital radiographs are available, the dental image analyzer tool can reliably replace the conventional method for measuring alveolar bone loss in periodontitis patients. [source] A Randomized, Double-blind, Sham-controlled Trial Comparing Two Screening Devices for Radiation ContaminationACADEMIC EMERGENCY MEDICINE, Issue 9 2010Philip Salen MD Abstract Objectives:, This exploratory study compared the screening ability of a newly introduced radiation detection portal with a traditional Geiger counter for detection of radiation contamination in the setting of a mass casualty training exercise. Methods:, Following a pretrial evaluation of interobserver reliability for Geiger counter use, 30 volunteers were randomly assigned to don gowns containing three disks, each of which was either a sham resembling the radioactive samples or an actual cesium-137 sample; each subject participated a minimum of four times with different gowns each time. Each subject underwent standard radioactivity screening with the Geiger counter and the portal. Results:, Interobserver reliability was excellent between the two Geiger counter screeners in the pretrial exercise, correctly identifying 101 of 102 sham and radioactive samples (, = 0.98; 95% confidence interval [CI] = 0.94 to 1.00). For radioactively labeled subjects across all bodily locations, the portal (43/61, or 70.5%; 95% CI = 58.1% to 80.5%) was less sensitive than the Geiger counter screening (61/61, or 100%; 95% CI = 92.9% to 100%), which resulted in a portal false-negative rate of 29.5%. For radiation detection in the posterior thorax, the portal radiation screening (4/19, or 21.1%; 95% CI = 8% to 43.9%) was less accurate than the Geiger counter (19/19, or 100%; 95% CI 80.2% to 100%). In contrast, there were no major differences between the portal and the Geiger counter for radiation detection at the left shoulder, right shoulder, or sham (nonradiation) detection. There were no false-positive detections of the sham-labeled subjects for either device, yielding a specificity of 100% for both screening modalities. Conclusions:, Geiger counter screening was more sensitive than, and equally specific to, radiation detection portal screening in detecting radioactively labeled subjects during a radiation mass casualty drill. ACADEMIC EMERGENCY MEDICINE 2010; 17:1020,1023 © 2010 by the Society for Academic Emergency Medicine [source] Medico-legal assessment of disability in narcolepsy: an interobserver reliability studyJOURNAL OF SLEEP RESEARCH, Issue 1 2008FRANCESCA INGRAVALLO Summary Impairment because of narcolepsy strongly limits job performance, but there are no standard criteria to assess disability in people with narcolepsy and a scale of disease severity is still lacking. We explored: (1) the interobserver reliability among Italian Medical Commissions making disability and handicap benefit decisions for people with narcolepsy, searching for correlations between the recognized disability degree and patients' features; (2) the willingness to report patients to the driving licence authority and (3) possible sources of variance in judgement. Fifteen narcoleptic patients were examined by four Medical Commissions in simulated sessions. Raw agreement and interobserver reliability among Commissions were calculated for disability and handicap benefit decisions and for driving licence decisions. Levels of judgement differed on percentage of disability (P < 0.001), severity of handicap (P = 0.0007) and the need to inform the driving licence authority (P = 0.032). Interobserver reliability ranged from Kappa = ,0.10 to 0.35 for disability benefit decision and from Kappa = ,0.26 to 0.36 for handicap benefit decision. The raw agreement on driving licence decision ranged from 73% to 100% (Kappa not calculable). Spearman's correlation between percentages of disability and patients' features showed correlations with age, daytime naps, sleepiness, cataplexy and quality of life. This first interobserver reliability study on social benefit decisions for narcolepsy shows the difficulty of reaching an agreement in this field, mainly because of variance in interpretation of the assessment criteria. The minimum set of indicators of disease severity correlating with patients' self assessments encourages a disability classification of narcolepsy. [source] European Federation of Neurological Societies/Peripheral Nerve Society Guideline on the use of skin biopsy in the diagnosis of small fiber neuropathy.JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, Issue 2 2010Report of a joint task force of the European Federation of Neurological Societies, the Peripheral Nerve Society Revision of the guidelines on the use of skin biopsy in the diagnosis of peripheral neuropathy, published in 2005, has become appropriate due to publication of more relevant papers. Most of the new studies focused on small fiber neuropathy (SFN), a subtype of neuropathy for which the diagnosis was first developed through skin biopsy examination. This revision focuses on the use of this technique to diagnose SFN. Task force members searched the Medline database from 2005, the year of the publication of the first EFNS guideline, to June 30th, 2009. All pertinent papers were rated according to the EFNS and PNS guidance. After a consensus meeting, the task force members created a manuscript that was subsequently revised by two experts (JML and JVS) in the field of peripheral neuropathy and clinical neurophysiology, who were not previously involved in the use of skin biopsy. Distal leg skin biopsy with quantification of the linear density of intraepidermal nerve fibers (IENF), using generally agreed upon counting rules, is a reliable and efficient technique to assess the diagnosis of SFN (level A recommendation). Normative reference values are available for bright-field immunohistochemistry (level A recommendation) but not yet for confocal immunofluorescence or the blister technique. The morphometric analysis of IENF density, either performed with bright-field or immunofluorescence microscopy, should always refer to normative values matched for age (level A recommendation). Newly established laboratories should undergo adequate training in a well established skin biopsy laboratory and provide their own stratified age and gender-matched normative values, intra- and interobserver reliability, and interlaboratory agreement. Quality control of the procedure at all levels is mandatory (Good Practice Point). Procedures to quantify subepidermal nerve fibers and autonomic innervated structures, including erector pili muscles, and skin vessels are under development but need to be confirmed by further studies. Sweat gland innervation can be examined using an unbiased stereologic technique recently proposed (level B recommendation). A reduced IENF density is associated with the risk of developing neuropathic pain (level B recommendation), but it does not correlate with its intensity. Serial skin biopsies might be useful for detecting early changes of IENF density, which predict the progression of neuropathy, and to assess degeneration and regeneration of IENF (level C recommendation). However, further studies are warranted to confirm the potential usefulness of skin biopsy with measurement of IENF density as an outcome measure in clinical practice and research. Skin biopsy has not so far been useful for identifying the etiology of SFN. Finally, we emphasize that 3-mm skin biopsy at the ankle is a safe procedure based on the experience of 10 laboratories reporting absence of serious side effects in approximately 35,000 biopsies and a mere 0.19% incidence of non-serious side effects in about 15 years of practice (Good Practice Point). [source] Quantification of Video-Taped Images in Microcirculation Research Using Inexpensive Imaging Software (Adobe Photoshop)MICROCIRCULATION, Issue 2 2000Joachim Brunner ABSTRACT Background: Study end-points in microcirculation research are usually videotaped images rather than numeric computer print-outs. Analysis of these videotaped images for the quantification of microcirculatory parameters usually requires computer-based image analysis systems. Most software programs for image analysis are custom-made, expensive, and limited in their applicability to selected parameters and study end-points. Methods and Result: We demonstrate herein that an inexpensive, commercially available computer software (Adobe Photoshop), run on a Macintosh G3 computer with inbuilt graphic capture board provides versatile, easy to use tools for the quantification of digitized video images. Using images obtained by intravital fluorescence microscopy from the pre- and postischemic muscle microcirculation in the skinfold chamber model in hamsters, Photoshop allows simple and rapid quantification (i) of microvessel diameters, (ii) of the functional capillary density and (iii) of postischemic leakage of FITC-labeled high molecular weight dextran from postcapillary venules. We present evidence of the technical accuracy of the software tools and of a high degree of interobserver reliability. Conclusions: Inexpensive commercially available imaging programs (i.e., Adobe Photoshop) provide versatile tools for image analysis with a wide range of potential applications in microcirculation research. [source] Digit ratios (2D:4D) determined by computer-assisted analysis are more reliable than those using physical measurements, photocopies, and printed scansAMERICAN JOURNAL OF HUMAN BIOLOGY, Issue 3 2009Heather C. Allaway Prenatal androgens influence the second to fourth digit ratio (2D:4D) of hands with men having lower ratios than women. Numerous methods are used to assess 2D:4D including, physical measurements with calipers, and measurements made from photocopies, scanned images, digital photographs, radiographs, and scaled tubes. Although each method appears relatively reliable, agreement upon a gold standard is necessary to better explore the putative effects of prenatal androgens. Our objective was to assess the level of intra and interobserver reliability when evaluating 2D:4D using four techniques: (1) physical measurements, (2) photocopies, (3) printed scanned images, and (4) computer-assisted image analysis. Physical measurements, photocopies, and printed scanned images were measured with Vernier calipers. Scanned images were also measured with computer-based calipers. Measurements were made in 30 men and 30 women at two different time points, by three experienced observers. Intraclass correlation coefficients were used to assess the level of reliability. Intraobserver reliability was best for computer-assisted (0.957), followed by photocopies (0.939), physical measurements (0.925), and printed scans (0.842; P = 0.015). Interobserver reliability was also greatest for computer-assisted (0.892), followed by photocopies (0.858), physical measurements (0.795), and printed scans (0.761; P = 0.001). Mean 2D:4D from physical measurements were higher than all other techniques (P < 0.0001). Digit ratios determined from computer-assisted, physical measurements, and printed scans were more reliable in men than women (P = 0.009, P = 0.017, and P = 0.012, respectively). In summary, 2D:4D determined from computer-assisted analysis yielded the most accurate and consistent measurements among observers. Investigations of 2D:4D should use computer-assisted measurements over alternate methods whenever possible. Am. J. Hum. Biol., 2009. © 2009 Wiley-Liss, Inc. [source] The Validity and Reliability of the Reflux Finding Score (RFS),THE LARYNGOSCOPE, Issue 8 2001Peter C. Belafsky MD Abstract Background The evaluation of medical and surgical outcomes relies on methods of accurately quantifying treatment results. Currently, there is no validated instrument whose purpose is to document the physical findings and severity of laryngopharyngeal reflux (LPR). Objective To evaluate the validity and reliability of the reflux finding score (RFS). Methods Forty patients with LPR confirmed by double-probe pH monitoring were evaluated pretreatment and 2, 4, and 6 months after treatment. The RFS was documented for each patient at each visit. For test,retest intraobserver reliability assessment, a blinded laryngologist determined the RFS on two separate occasions. To evaluate interobserver reliability, the RFS was determined by two different blinded laryngologists. Results The mean age of the cohort was 50 years (± 12 standard deviation [SD]). Seventy-three percent were women. The RFS at entry was 11.5 (± 5.2 SD). This score improved to 9.3 (± 4.7 SD) at 2 months, 7.3 (± 5.5 SD) at 4 months, and 6.1 (± 5.2 SD) at 6 months of treatment (P <.001 with trend). The mean RFS for laryngologist no. 1 was 10.8 (± 4.1 SD) at the initial screening and 10.8 (± 4.0 SD) at the repeat evaluation (r = 0.95, P <.001). The mean RFS for laryngologist no. 2 was 11.1 (± 3.8 SD) at the initial screening and 10.9 (± 3.7 SD) at the repeat evaluation (r = 0.95, P <.001). The correlation coefficient for interobserver variability was 0.90 (P <.001). Conclusions The RFS accurately documents treatment efficacy in patients with LPR. It demonstrates excellent inter- and intraobserver reproducibility. [source] The Measurement of the QT and QTc on the Neonatal and Infant Electrocardiogram: A Comprehensive Reliability AssessmentANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2 2009B.S., Robert M. Gow M.B. Background: An electrocardiogram has been proposed to screen for prolonged QT interval that may predispose infants to sudden death in the first year of life. Understanding the reliability of QT interval measurement will inform the design of a screening program. Methods: Three pediatric cardiologists measured the QT/RR intervals on 60 infant electrocardiograms (median age 46 days), from leads II, V5 and V6 on three separate occasions, 7 days apart, according to a standard protocol. The QTc was corrected by Bazett's (QTcB), Fridericia's (QTCFrid), and Hodges' (QTcH) formulae. Intraobserver and interobserver reliability were assessed by intraclass correlation coefficients (ICC), limits of agreement and repeatability coefficients for single, average of two and average of three measures. Agreement for QTc prolongation (> 440 msec) was assessed by kappa coefficients. Results: QT interval intraobserver ICC was 0.86 and repeatability coefficient was 25.9 msec; interobserver ICC increased from 0.88 for single observations to 0.94 for the average of 3 measurements and repeatability coefficients decreased from 22.5 to 16.7 msec. For QTcB, intraobserver ICC was 0.67, and repeatability was 39.6 msec. Best interobserver reliability for QTcB was for the average of three measurements (ICC 0.83, reproducibility coefficient 25.8 msec), with further improvement for QTcH (ICC 0.92, reproducibility coefficient 16.69 msec). Maximum interobserver kappa for prolonged QTc was 0.77. Misclassification around specific cut points occurs because of the repeatability coefficients. Conclusions: Uncorrected QT measures are more reliable than QTcB and QTCFrid. An average of three independent measures provides the most reliable QT and QTc measurements, with QTcH better than QTcB. [source] Dysplastic naevi with moderate to severe histological dysplasia: a risk factor for melanomaBRITISH JOURNAL OF DERMATOLOGY, Issue 5 2006A.R. Shors Summary Background, The risk of malignant melanoma associated with histologically dysplastic naevi (HDN) has not been defined. While clinically atypical naevi appear to confer an independent risk of melanoma, no study has evaluated the extent to which HDN are predictive of melanoma. Objectives, To estimate the risk of melanoma associated with HDN. Secondarily, the risk associated with number of naevi and large naevi is estimated. Methods, We enrolled 80 patients with newly diagnosed melanoma along with 80 spousal controls. After obtaining information on melanoma risk factors and performing a complete cutaneous examination, the most clinically atypical naevus was biopsied in both cases and controls. Histological dysplasia was then assessed independently by 13 dermatopathologists (0, no dysplasia; 1, mild dysplasia; 2, moderate dysplasia; 3, severe dysplasia). The dermatopathologists were blinded as to whether the naevi were from melanoma subjects or controls. Multivariate analyses were performed to determine if there was an independent association between the degree of histological dysplasia in naevi and a personal history of melanoma. Results, In persons with naevi receiving an average score of > 1 (i.e. naevi considered to have greater than mild histological dysplasia), there was an increased risk of melanoma [odds ratio (OR) 2·60, 95% confidence interval (CI) 0·99,6·86] which persisted after adjustment for confounders (OR 3·99, 95% CI 1·02,15·71). Very few dermatopathologists reliably graded naevi of subjects with melanoma as being more dysplastic than naevi of control subjects. Among the entire group, the interobserver reliability associated with grading histological dysplasia in naevi was poor (weighted kappa 0·28). Conclusions, HDN do appear to confer an independent risk of melanoma. However, this result may add more to our biological understanding of melanoma risk than to clinical assessment of risk, because HDN assessed by a single pathologist generally cannot be used to assess risk of melanoma. Future studies should be directed at establishing reproducible, predictive criteria for grading naevi. [source] Distinguishing Parkinson's disease and essential tremor with transcranial sonographyACTA NEUROLOGICA SCANDINAVICA, Issue 1 2009M. Budisic Objectives,,, Until today there is no reliable test that can clearly distinguish Parkinson's disease (PD) from the essential tremor (ET). Our aim was to determine the usefulness of the transcranial sonography (TCS) in the differential diagnosis of the PD and ET as well as the interobserver reliability for this method. Methods,,, Transcranial sonography of substantia nigra and clinical examination were performed on 80 PD patients, 30 ET patients, and 80 matched controls by two independent physicians. Results,,, Bilateral SN hyperechogenicity over the margin of 0.20 cm2 was found in 91% of PD patients, 10% of healthy subjects, and in 13% patients with ET. Interobserver agreement for this method was significant (Student's t -test, P = 1.000). Conclusions,,, Substantia nigra hyperechogenicity on TCS is a highly specific finding of PD, where in healthy individuals or in ET patients, it might correspond to an increased risk of developing PD later in life or might also be because of the impairment of nearby area of nucleus ruber in ET patients, as suggested by positron emission tomography studies. TCS may serve as a practical and sufficiently sensitive neuroimaging tool in PD diagnoses and in distinguishing it from ET; its repeatability and accuracy might add to its practical value. [source] Development of adaptive motor behaviour in typically developing infantsACTA PAEDIATRICA, Issue 4 2010KR Heineman Abstract Aim:, During motor development, infants learn to select adaptive motor strategies out of their motor repertoire. The aim of this study is twofold: first, to investigate whether the presence of adaptive motor behaviour can be observed reliably, and second, to explore the ages at which clinically observable transition to adaptive motility emerges for four specific motor functions: abdominal progression, sitting motility, reaching and grasping. Methods:, The reliability part of the study included 38 assessments of term and preterm infants in the age range of 4,18 months. The longitudinal prospective study included 30 term born typically developing infants with nine assessments between 3 and 18 months. On the basis of standardized video-recordings of spontaneous motor behaviour, the presence of adaptive motor strategies was scored. Results:, Intra- and interobserver reliability were good. Clinically observable transitions to adaptive selection started to emerge from 6 months onwards and peaked between 8 and 15 months. Transitions developed gradually and occurred at specific ages for different motor functions. Conclusion:, Transition to adaptive motor behaviour can be observed reliably. Adaptive motor behaviour develops gradually from 6 months onwards at function-specific ages. Comparison of our results to literature showed that changes measured by neurophysiologic methods precede clinically observed transitions. [source] Interobserver reliability of the Nail Psoriasis Severity IndexCLINICAL & EXPERIMENTAL DERMATOLOGY, Issue 2 2007. Aktan Summary Background., Because the Psoriasis Area and Severity Index (PASI) does not consider the severity of nail disease, a scale that assesses the extent of involvement of psoriatic nails is needed. A new grading system, the Nail Psoriasis Severity Index (NAPSI) has been proposed. Aims., The purpose of this study was to assess the interobserver reliability of NAPSI. Methods., The nail features of 25 patients with psoriasis with nail involvement were evaluated and graded by three dermatologists for total NAPSI scores and nail scores. The quadrants of all nails were examined for the presence of matrix and bed features. Total NAPSI score (0,160) of patients and nail score (0,32) of the individual nails were calculated. Interobserver reliability assessments were performed by computing intraclass correlation coefficients (ICC; two-way mixed model, consistency definition). Results., The ICC(3,1) results for total NAPSI score and nail score were found to be 0.781 and 0.649, respectively. The ICC(3,1) for nail-bed and nail-matrix features were 0.869 and 0.584, respectively, in the total NAPSI scoring system, and 0.705 and 0.603, respectively, in the nail scoring system. Conclusion., Moderate to good agreement of scoring with the NAPSI was determined among the observers in this study. Our results suggest that scoring for nail-bed features seems to be more reliable than scoring for nail-matrix features. [source] |