Imaging Parameters (imaging + parameter)

Distribution by Scientific Domains
Distribution within Medical Sciences


Selected Abstracts


Age- and Sex-Related Differences in the Tissue Doppler Imaging Parameters of Left Ventricular Diastolic Dysfunction

ECHOCARDIOGRAPHY, Issue 6 2007
Hyeun S. Park M.D.
Background: The effect of age and gender on tissue Doppler imaging measurements comparing the septal and mitral annulus needs to be investigated. Methods: We investigated in 276 outpatients in a university cardiology practice the relationship of age and gender to left atrial (LA) size, LA volume, mitral pulse-wave Doppler E/A ratio, E/Ea ratios by tissue Doppler image of mitral annular velocity (TDI), and left ventricular diastolic dysfunction (LVDD) by TDI. Results: Mitral E/A inflow was statistically decreased with age. E/Ea ratios of the lateral and mean of both lateral and septal annulus showed a statistical increase with age, while the E/Ea ratio of the septal annulus did not correlate with age. When comparing men and women of all ages, the mean LA volume for men was 59.2 cm3± 24.36 cm3 versus 48.54 cm3± 16.14 cm3 (P-value < 0.0001) and the mean LA size was 4.0 + 0.51 cm for men and 3.65 + 0.47 for women (P-value < 0.0001). There was no statistical difference between men and women when looking at mitral E/A inflow ratio, deceleration time, E/Ea ratio of the septal annulus, E/Ea ratio of the lateral annulus, E/Ea ratio of the mean of both septal and lateral annulus, and grades of LVDD. Conclusion: In patients 70 years of age or older, the mean diastolic grade was mild-to-moderate LVDD when using lateral or mean of septal and lateral annular measurements. When only the septal annular measurements were used to determine diastolic grade, all four age groups showed a mean of mildly to moderately impaired LVDD and showed no correlation with age. There were no differences in tissue Doppler imaging measurements between men and women. [source]


XTC MRI: Sensitivity improvement through parameter optimization

MAGNETIC RESONANCE IN MEDICINE, Issue 6 2007
Kai Ruppert
Abstract Xenon polarization Transfer Contrast (XTC) MRI pulse sequences permit the gas exchange of hyperpolarized xenon-129 in the lung to be measured quantitatively. However, the pulse sequence parameter values employed in previously published work were determined empirically without considering the now-known gas exchange rates and the underlying lung physiology. By using a theoretical model for the consumption of magnetization during data acquisition, the noise intensity in the computed gas-phase depolarization maps was minimized as a function of the gas-phase depolarization rate. With such optimization the theoretical model predicted an up to threefold improvement in precision. Experiments in rabbits demonstrated that for typical imaging parameter values the optimized XTC pulse sequence yielded a median noise intensity of only about 3% in the depolarization maps. Consequently, the reliable detection of variations in the average alveolar wall thickness of as little as 300 nm can be expected. This improvement in the precision of the XTC MRI technique should lead to a substantial increase in its sensitivity for detecting pathological changes in lung function. Magn Reson Med 57:1099,1109, 2007. © 2007 Wiley-Liss, Inc. [source]


Routine clinical brain MRI sequences for use at 3.0 Tesla

JOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 1 2005
Hanzhang Lu PhD
Abstract Purpose To establish image parameters for some routine clinical brain MRI pulse sequences at 3.0 T with the goal of maintaining, as much as possible, the well-characterized 1.5-T image contrast characteristics for daily clinical diagnosis, while benefiting from the increased signal to noise at higher field. Materials and Methods A total of 10 healthy subjects were scanned on 1.5-T and 3.0-T systems for T1 and T2 relaxation time measurements of major gray and white matter structures. The relaxation times were subsequently used to determine 3.0-T acquisition parameters for spin-echo (SE), T1 -weighted, fast spin echo (FSE) or turbo spin echo (TSE), T2 -weighted, and fluid-attenuated inversion recovery (FLAIR) pulse sequences that give image characteristics comparable to 1.5 T, to facilitate routine clinical diagnostics. Application of the routine clinical sequences was performed in 10 subjects, five normal subjects and five patients with various pathologies. Results T1 and T2 relaxation times were, respectively, 14% to 30% longer and 12% to 19% shorter at 3.0 T when compared to the values at 1.5 T, depending on the region evaluated. When using appropriate parameters, routine clinical images acquired at 3.0 T showed similar image characteristics to those obtained at 1.5 T, but with higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), which can be used to reduce the number of averages and scan times. Recommended imaging parameters for these sequences are provided. Conclusion When parameters are adjusted for changes in relaxation rates, routine clinical scans at 3.0 T can provide similar image appearance as 1.5 T, but with superior image quality and/or increased speed. J. Magn. Reson. Imaging 2005;22:13,22. © 2005 Wiley-Liss, Inc. [source]


Comparison of relative forced expiratory volume of one second with dynamic magnetic resonance imaging parameters in healthy subjects and patients with lung cancer,

JOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 3 2005
Christian Plathow MD
Abstract Purpose To assess relative forced expiratory volume in one second (FEV1/vital capacity (VC)) in healthy subjects and patients with a lung tumor using dynamic magnetic resonance imaging (dMRI) parameters. Materials and Methods In 15 healthy volunteers and 31 patients with a non-small-cell lung carcinoma stage I (NSCLC I), diaphragmatic length change (LE1) and craniocaudal (CC) intrathoracic distance change within one second from maximal inspiration (DE1) were divided by total length change (LEtotal, DEtotal) as a surrogate of spirometric FEV1/VC using a true fast imaging with steady-state precession (trueFISP) sequence (TE/TR = 1.7/37.3 msec, temporal resolution = 3 images/second). Influence of tumor localization was examined. Results In healthy volunteers FEV1/VC showed a highly significant correlation with LE1/LEtotal and DE1/DEtotal (r > 0.9, P < 0.01). In stage IB tumor patients, comparing tumor-bearing with the non-tumor-bearing hemithorax, there was a significant difference in tumors of the middle (LE1/LEtotal = 0.63 ± 0.05 vs. 0.73 ± 0.04, DE1/DEtotal = 0.66 ± 0.05 vs. 0.72 ± 0.04; P < 0.05) and lower (P < 0.05) lung region. Stage IA tumor patients showed no significant differences with regard to healthy subjects. Conclusion dMRI is a simple noninvasive method to locally determine LE1/LEtotal and DE1/DEtotal as a surrogate of FEV1/VC in volunteers and patients. Tumors of the middle and lower lung regions have a significant influence on these MRI parameters. J. Magn. Reson. Imaging 2005;21:212,218. © 2005 Wiley-Liss, Inc. [source]


Effect of black blood MR image quality on vessel wall segmentation

MAGNETIC RESONANCE IN MEDICINE, Issue 2 2001
Jonathan B. Thomas
Abstract Black blood MRI has become a popular technique for measuring arterial wall area as an indicator of plaque size. Computer-assisted techniques for segmenting vessel boundaries have been developed to increase measurement precision. In this study, the carotid arteries of four normal subjects were imaged at seven different fields of view (FOVs), keeping all other imaging parameters fixed, to determine whether spatial resolution could be increased at the expense of image quality without sacrificing precision. Wall areas were measured via computer-assisted segmentation of the vessel boundaries performed repeatedly by two operators. Analysis of variance (ANOVA) demonstrated that the variability of wall area measurements was below 1.5 mm2 for in-plane spatial resolutions between 0.22 mm and 0.37 mm. An inverse relationship between operator variability and the signal difference-to-noise ratio (SDNR) demonstrated that semi-automatic segmentation of the wall boundaries was robust for SDNR >3, defining a criterion above which subjective image quality can be degraded without an appreciable loss of information content. Our study also suggested that spatial resolutions higher than 0.3 mm may be required to quantify normal wall areas to within 10% accuracy, but that the reduced SNR associated with the higher resolution may be tolerated by semi-automated wall segmentation without an appreciable loss of precision. Magn Reson Med 46:299,304, 2001. © 2001 Wiley-Liss, Inc. [source]


The small airways and distal lung compartment in asthma and COPD: a time for reappraisal

ALLERGY, Issue 2 2010
M. Contoli
To cite this article: Contoli M, Bousquet J, Fabbri LM, Magnussen H, Rabe KF, Siafakas NM, Hamid Q, Kraft M. The small airways and distal lung compartment in asthma and COPD: a time for reappraisal. Allergy 2010; 65: 141,151. Abstract The involvement of small airways in the pathogenesis of asthma and chronic obstructive pulmonary disease (COPD) has been debated for a long time. However, a proper definition of small airway disease is still lacking, and neither a widely accepted biomarker nor a functional parameter to assess small airway abnormalities and to explore the effect of tested compounds on small airways is available. Aiming towards increased knowledge and consensus on this topic, this perspective paper intends to (i) strengthen awareness among the scientific community on the role of small airways in asthma and COPD; (ii) examine the pros and cons of some biological, functional and imaging parameters in the assessment of small airway abnormalities; and (iii) discuss the evidence for distal airway pharmacological targeting in asthma and COPD. [source]


Molecular Breast Imaging: Advantages and Limitations of a Scintimammographic Technique in Patients with Small Breast Tumors

THE BREAST JOURNAL, Issue 1 2007
Michael K. O'Connor PhD
Abstract:, Preliminary studies from our laboratory showed that molecular breast imaging (MBI) can reliably detect tumors <2 cm in diameter. This study extends our work to a larger patient population and examines the technical factors that influence the ability of MBI to detect small breast tumors. Following injection of 740 MBq Tc-99m sestamibi, MBI was performed on 100 patients scheduled for biopsy of a lesion suspicious for malignancy that measured <2 cm on mammography or sonography. Using a small field of view gamma camera, patients were imaged in the standard mammographic views using light pain-free compression. Subjective discomfort, breast thickness, the amount of breast tissue in the detector field of view, and breast counts per unit area were measured and recorded. Follow-up was obtained in 99 patients; 53 patients had 67 malignant tumors confirmed at surgery. Of these, 57 of 67 were detected by MBI (sensitivity 85%). Sensitivity was 29%, 86%, and 97% for tumors <5, 6,10, and ,11 mm in diameter, respectively. In seven patients, MBI identified eight additional mammographically occult tumors. Of 47 patients with no evidence of cancer at biopsy or surgery, there were 36 true negative and 11 false positive scans on MBI. MBI has potential for the regular detection of malignant breast tumors less than 2 cm in diameter. Work in progress to optimize the imaging parameters and technique may further improve sensitivity and specificity. [source]


Cognitive impairment and white matter damage in hypertension: a pilot study

ACTA NEUROLOGICA SCANDINAVICA, Issue 4 2009
K. Hannesdottir
Objectives,,, Hypertension has been associated with impaired cognition. Diffusion tensor imaging (DTI) and magnetic resonance spectroscopy were applied to assess white matter abnormalities in treated vs untreated hypertension and if these correlated with neuropsychological performance. Methods,,, Subjects were 40 patients with medically treated hypertension (mean age 69.3 years), 10 patients with untreated hypertension (mean age 57.6 years) and 30 normotensive controls (mean age 68.2 years). Hypertension was defined as a previous diagnosis and taking hypertensive medication, or a resting blood pressure of >140/90 mmHg on the day of assessment. Results,,, Patients with treated hypertension performed worse on immediate (P = 0.037) as well as delayed memory tasks (P = 0.024) compared with normotensive controls. Cognitive performance was worse in untreated compared with treated hypertension on executive functions (P = 0.041) and psychomotor speed (P = 0.003). There was no significant correlation between cognition and any of the imaging parameters in treated hypertension. However, in untreated hypertension the results revealed a positive correlation between an executive functioning and attention composite score and DTI mean diffusivity values (P = 0.016) and between psychomotor speed and spectroscopy NAA/tCr levels (P = 0.015). Conclusions,,, These results suggest there is cognitive impairment in hypertension. Treated hypertension was associated with deficits in memory while untreated hypertension revealed a more ,subcortical' pattern of cognitive impairment. [source]