Home About us Contact | |||
Ion Mass Spectra (ion + mass_spectrum)
Kinds of Ion Mass Spectra Selected AbstractsAccurate product ion mass spectra of galanthamine derivativesJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 4 2006A. Jegorov [source] Metabolites of an orally active antimicrobial prodrug, 2,5-bis(4-amidinophenyl)furan-bis- O -methylamidoxime, identified by liquid chromatography/tandem mass spectrometryJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 4 2004Lian Zhou Abstract DB75 (2,5-bis(4-amidinophenyl)furan) is a promising antimicrobial agent against African trypanosomiasis and Pneumocystis carinii pneumonia. However, it suffers from poor oral activity in rodent models for both infections. In contrast, a novel prodrug of DB75, 2,5-bis(4-amidinophenyl)furan-bis- O -methylamidoxime (DB289), has excellent oral activity. DB289 is currently undergoing clinical investigation as a candidate drug to treat primary stage African trypanosomiasis and Pneumocystis carinii pneumonia. In this study, metabolites of DB289 formed after incubation with freshly isolated rat hepatocytes were characterized using liquid chromatography/ion trap mass spectrometry. Administration of DB289 and octadeuterated DB289 in a 1 : 1 mixture greatly facilitated metabolite identification by providing isotope patterns with twin ions separated by 8 m/z units in the ratio 1 : 1, in the extracted ion chromatograms of molecular ions and in the product ion mass spectra of metabolites. Ten metabolites were identified. Series of O -demethylations and N -dehydroxylations led to the metabolic activation of DB289 to DB75 with the production of four intermediate phase I metabolites. Phase II glucuronidation and sulfation led to the formation of four glucuronide and one sulfate metabolites. Copyright © 2004 John Wiley & Sons, Ltd. [source] Fragmentation pathways of acylated flavonoid diglucuronides from leaves of Medicago truncatulaPHYTOCHEMICAL ANALYSIS, Issue 3 2010ukasz Marczak Abstract Introduction , Flavonoids are important plant compounds occurring in tissues mostly in the form of glycoconjugates. Most frequently the sugar moiety is comprised of mono- or oligosaccharides consisting of common sugars like glucose, rhamnose or galactose. In some plant species the glycosidic moiety contains glucuronic acid and may be acylated by phenylpropenoic acids. Methodology , Flavonoid glyconjugates were extracted from leaves of Medicago truncatula ecotype R108 and submitted to analysis using high-performance liquid chromatography combined with high-resolution tandem (quadrupole-time of flight, QToF) mass spectrometry. Results , The studied leaf extracts contained 26 different flavonoid glycosides among which 22 compounds were flavone (apigenin, luteolin, chrysoeriol and tricin) glucuronides and 13 were acylated with aromatic acids (p -coumaric, ferulic or sinapic). The fragmentation pathways observed in positive and negative ion mass spectra differed substantially between each other and from these of flavonoid glycosides which did not contain acidic sugars. The application of high-resolution MS techniques allowed unequivocal differentiation between ions with the same nominal m/z values containing different substituents (e.g. ferulic acid or glucuronic acid). Eleven of the identified flavonoids have not been reported previously in this species. Perspectives , The presented unique fragmentation pathways of flavonoid glucuronates enable detection of these compounds in tissue extracts from different plant species. Copyright © 2009 John Wiley & Sons, Ltd. [source] Towards a universal product ion mass spectral library , reproducibility of product ion spectra across eleven different mass spectrometersRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 12 2008Chris Hopley Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry experiments can differ markedly between instruments. There have been a number of attempts to standardise the production of product ion spectra; however, a consensus on the most appropriate approach to the reproducible production of spectra has yet to be reached. We have previously reported the comparison of product ion spectra on a number of different types of instruments , a triple quadrupole, two ion traps and a Fourier transform ion cyclotron resonance mass spectrometer (Bristow AWT, Webb KS, Lubben AT, Halket JM. Rapid Commun. Mass Spectrom. 2004; 18: 1). The study showed that a high degree of reproducibility was achievable. The goal of this study was to improve the comparability and reproducibility of CID product ion mass spectra produced in different laboratories and using different instruments. This was carried out experimentally by defining a spectral calibration point on each mass spectrometer for product ion formation. The long-term goal is the development of a universal (instrument independent) product ion mass spectral library for the identification of unknowns. The spectra of 48 compounds have been recorded on eleven mass spectrometers: six ion traps, two triple quadrupoles, a hybrid triple quadrupole, and two quadrupole time-of-flight instruments. Initially, 4371 spectral comparisons were carried out using the data from eleven instruments and the degree of reproducibility was evaluated. A blind trial has also been carried out to assess the reproducibility of spectra obtained during LC/MS/MS. The results suggest a degree of reproducibility across all instrument types using the tuning point technique. The reproducibility of the product ion spectra is increased when comparing the tandem in time type instruments and the tandem in space instruments as two separate groups. This may allow the production of a more limited, yet useful, screening library for LC/MS/MS identification using instruments of the same type from different manufacturers. Copyright © 2008 John Wiley & Sons, Ltd. [source] Comparison of negative ion electrospray mass spectra measured by seven tandem mass analyzers towards library formationRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 2 2008ina Volná A library of negative ion electrospray ionization mass spectra and tandem mass spectra (MS/MS) of sulfonated dyes has been developed for fast identification purposes. The uniform protocol has been elaborated and applied to the measurements of more than 50 anionic dyes. Three collision energies are selected in our protocol which ensures that at least one of them provides a suitable ratio of product ions to the precursor ion. The robustness is investigated with altered values of tuning parameters (e.g. the pressure of the nebulizing gas, the temperature and the flow rate of drying gas, and the mobile phase composition). The results of the inter-laboratory comparison of product ion mass spectra recorded on seven different tandem mass spectrometers (three ion traps, two triple quadrupoles and two hybrid quadrupole time of flight instruments) are presented for four representative anionic dyes , azo dye Acid Red 118, anthraquinone dye Acid Violet 43, triphenylmethane dye Acid Blue 1 and Al(III) metal-complex azo dye. The fragmentation patterns are almost identical for all tandem mass analyzers, only the ratios of product ions differ somewhat which confirms the possibility of spectra transfer among different mass analyzers with the goal of library formation. Copyright © 2007 John Wiley & Sons, Ltd. [source] Electron capture dissociation mass spectrometry of peptide cations containing a lysine homologue: a mobile proton model for explaining the observation of b-type product ionsRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 21 2006Sunyoung Lee Eleven doubly protonated peptides with a residue homologous to lysine were investigated by electron capture dissociation mass spectrometry (ECD-MS). Lysine homologues provide the unique opportunity to examine the ECD fragmentation behavior by allowing us to vary the length of the lysine side chain, with minimal structural change. The lysine homologue has a primary amine side chain with a length that successively decreases by one methylene (CH2) unit from the CH2CH2CH2CH2NH2 of lysine and the accompanying decrease of its proton affinities: lysine (K), 1006.5(±7.2) kJ/mol; ornithine (K*), 1001.1(±6.6) kJ/mol; 2,4-diaminobutanoic acid (K**), 975.8(±7.4) kJ/mol; 2,3-diaminopropanoic acid (K***), 950.2(±7.2) kJ/mol. In general, the lysine-homologous peptides exhibited overall ECD fragmentation patterns similar to that of the lysine-containing peptides in terms of the locations, abundances, and ion types of products, such as yielding c+ and z+. ions as the dominant product ions. However, a close inspection of product ion mass spectra showed that ECD-MS for the alanine-rich peptides with an ornithinyl or 2,4-diaminobutanoyl residue gave rise to b ions, while the lysinyl-residue-containing peptides did not, in most cases, produce any b ions. The peptide selectivity in the generation of b+ ions could be understood from within the framework of the mobile proton model in ECD-MS, previously proposed by Cooper (Ref. 29). The exact mass analysis of the resultant b ions reveals that these b ions are not radical species but rather the cationic species with R-CO+ structure (or protonated oxozalone ion), that is, b+ ions. The absence of [M+2H]+. species in the ECD mass spectra and the selective b+ -ion formation are evidence that the peptides underwent H-atom loss upon electron capture, and then the resulting reduced species dissociated following typical MS/MS fragmentation pathways. This explanation was further supported by extensive b+ ions generated in the ECD of alanine-based peptides with extended conformations. Copyright © 2006 John Wiley & Sons, Ltd. [source] Product ion mass spectra of amphetamine-type substances, designer analogues, and ketamine using ultra-performance liquid chromatography/tandem mass spectrometry,RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 15 2006Luigino G. Apollonio This paper describes the application of ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) technology to separate and identify amphetamine-type substances (amphetamine, methamphetamine), common and novel designer analogues (MDA, MDMA, PMA, 4-MTA, MBDB), and ketamine using Acquity UPLC/Micromass Quattro Micro API mass spectrometer instrumentation (Waters Corporation, USA). From injection of drug reference standards, it was demonstrated that these compounds can be identified by product ion mass spectra in less than 4,min total analysis time, indicating that the technological advancements associated with UPLC/MS/MS allow it to serve as a powerful analytical tool for high-throughput testing. In addition to demonstrating the separation and response of these drug compounds under the stated UPLC/MS/MS conditions, we believe the acquired product ion spectra will be a beneficial reference to laboratories interested in incorporating the use of this technology in the routine analysis of drugs of abuse. Copyright © 2006 John Wiley & Sons, Ltd. [source] Assessment of the plasma desorption time-of-flight mass spectrometry technique for pesticide adsorption and degradation on ,as-received' treated soil samplesRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 17 2005J. P. Thomas The assessment of the plasma desorption time-of-flight mass spectrometry (PD-TOFMS) technique as a tool for direct characterization of pesticides adsorbed on agricultural soil is made for the first time in this study. Pellets of soils impregnated by solutions of three pesticides, namely norflurazon, malathion and oxyfluorfen, as well as deposits of these solutions onto aluminum surfaces, were investigated to this end. The yield values of the most characteristic peaks of the negative ion mass spectra were used to determine both the lowest concentrations detected on soils and limits of detection from thin films. The lowest values on soils are for malathion (1000,ppm range), and the largest for norflurazon (20,000,ppm), which is close to the limit of detection (LOD) found for the pesticide on the aluminum substrate (,0.2,µg,·,cm,2). Different behaviors were observed as a function of time of storage in the ambient atmosphere or under vacuum; norflurazon adsorbed on soil exhibited high stability for a long period of time, and a rapid degradation of malathion with the elapsed time was clearly observed. The behavior of oxyfluorfen was also investigated but segregation processes seem to occur after several days. Although by far less sensitive than conventional methods based on extraction processes and used for real-world analytical applications, this technique is well suited to the study of the transformations occurring at the sample surface. A discussion is presented of the future prospects of such experiments in degradation studies. Copyright © 2005 John Wiley & Sons, Ltd. [source] On the use of ESI-QqTOF-MS/MS for the comparative sequencing of nucleic acidsBIOPOLYMERS, Issue 6 2009Herbert Oberacher Abstract The usability of a quadrupole,quadrupole,time-of-flight (QqTOF) instrument for the tandem mass spectrometric sequencing of oligodeoxynuleotides was investigated. The sample set consisted of 21 synthetic oligodeoxynucleotides ranging in length from 5 to 42 nucleotides. The sequences were randomly selected. For the majority of tested oligonucleotides, two or three different charge states were selected as precursor ions. Each precursor ion was fragmented applying several different collision voltages. Overall 282 fragment ion mass spectra were acquired. Computer-aided interpretation of fragment ion mass spectra was accomplished with a recently introduced comparative sequencing algorithm (COMPAS). The applied version of COMPAS was specifically optimized for the interpretation of information-rich spectra obtained on the QqTOF. Sequences of oligodeoxynucleotides as large as 26-mers were correctly verified in >94% of cases (182 of 192 spectra acquired). Fragment ion mass spectra of larger oligonucleotides were not specific enough for sequencing. Because of the occurrence of extensive internal fragmentation causing low sequence coverage paired with a high probability of assigning fragment ions to wrong sequences, tandem mass spectra obtained from oligonucleotides consisting of 30 and more nucleotides could not be used for sequence verification neither manually nor with COMPAS. © 2009 Wiley Periodicals, Inc. Biopolymers 91: 401,409, 2009. This article was originally published online as an accepted preprint. The "Published Online" date corresponds to the preprint version. You can request a copy of the preprint by emailing the Biopolymers editorial office at biopolymers@wiley.com [source] Using a triple-quadrupole mass spectrometer in accurate mass mode and an ion correlation program to identify compounds,RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 18 2005Andrew H. Grange Atomic masses and isotopic abundances are independent and complementary properties for discriminating among ion compositions. The number of possible ion compositions is greatly reduced by accurately measuring exact masses of monoisotopic ions and the relative isotopic abundances (RIAs) of the ions greater in mass by +1,Da and +2,Da. When both properties are measured, a mass error limit of 6,10,mDa (<,31,ppm at 320,Da) and an RIA error limit of 10% are generally adequate for determining unique ion compositions for precursor and fragment ions produced from small molecules (less than 320,Da in this study). ,Inherent interferences', i.e., mass peaks seen in the product ion mass spectrum of the monoisotopic [M+H]+ ion of an analyte that are ,2, ,1, +1, or +2,Da different in mass from monoisotopic fragment ion masses, distort measured RIAs. This problem is overcome using an ion correlation program to compare the numbers of atoms of each element in a precursor ion to the sum of those in each fragment ion and its corresponding neutral loss. Synergy occurs when accurate measurement of only one pair of +1,Da and +2,Da RIAs for the precursor ion or a fragment ion rejects all but one possible ion composition for that ion, thereby indirectly rejecting all but one fragment ion-neutral loss combination for other exact masses. A triple-quadrupole mass spectrometer with accurate mass capability, using atmospheric pressure chemical ionization (APCI), was used to measure masses and RIAs of precursor and fragment ions. Nine chemicals were investigated as simulated unknowns. Mass accuracy and RIA accuracy were sufficient to determine unique compositions for all precursor ions and all but two of 40 fragment ions, and the two corresponding neutral losses. Interrogation of the chemical literature provided between one and three possible compounds for each of the nine analytes. This approach for identifying compounds compensates for the lack of commercial ESI and APCI mass spectral libraries, which precludes making tentative identifications based on spectral matches. Published in 2005 by John Wiley & Sons, Ltd. [source] |