  • cardiac troponin i concentration
  • troponin i concentration


  • Selected Abstracts


    Serum Cardiac Troponin I Concentration in Dogs with Precapillary and Postcapillary Pulmonary Hypertension

    JOURNAL OF VETERINARY INTERNAL MEDICINE, Issue 1 2010
    C. Guglielmini
    Background: Pulmonary hypertension (PH) is a disease condition leading to right-sided cardiac hypertrophy and, eventually, right-sided heart failure. Cardiac troponin I (cTnI) is a circulating biomarker of cardiac damage. Hypothesis: Myocardial damage can occur in dogs with precapillary and postcapillary PH. Animals: One hundred and thirty-three dogs were examined: 26 healthy controls, 42 dogs with mitral valve disease (MVD) without PH, 48 dogs with pulmonary hypertension associated with mitral valve disease (PH-MVD), and 17 dogs with precapillary PH. Methods: Prospective, observational study. Serum cTnI concentration was measured with a commercially available immunoassay and results were compared between groups. Results: Median cTnI was 0.10 ng/mL (range 0.10,0.17 ng/mL) in healthy dogs. Compared with the healthy population, median serum cTnI concentration was increased in dogs with precapillary PH (0.25 ng/mL; range 0.10,1.9 ng/mL; P < .001) and in dogs with PH-MVD (0.21 ng/mL; range 0.10,2.10 ng/mL; P < .001). Median serum cTnI concentration of dogs with MVD (0.12 ng/mL; range 0.10,1.00 ng/mL) was not significantly different compared with control group and dogs with PH-MVD. In dogs with MVD and PH-MVD, only the subgroup with decompensated PH-MVD had significantly higher cTnI concentration compared with dogs with compensated MVD and PH-MVD. Serum cTnI concentration showed significant modest positive correlations with the calculated pulmonary artery systolic pressure in dogs with PH and some echocardiographic indices in dogs with MVD and PH-MVD. Conclusions and Clinical Importance: Serum cTnI is high in dogs with either precapillary and postcapillary PH. Myocardial damage in dogs with postcapillary PH is likely the consequence of increased severity of MVD. [source]


    Serum Cardiac Troponin I Concentration in Dogs with Ehrlichiosis

    JOURNAL OF VETERINARY INTERNAL MEDICINE, Issue 5 2008
    P.P.V.P. Diniz
    Background: Ehrlichiosis is a multisystemic disease with the potential to cause cardiomyocyte injury in naturally infected dogs. Hypothesis: Myocardial injury occurs in dogs infected with Ehrlichia canis. Animals: One-hundred and ninety-four dogs from Brazil with clinical and laboratory abnormalities indicative of ehrlichiosis. Sixteen healthy dogs served as controls. Methods: Electrocardiogram, echocardiogram, noninvasive blood pressure measurement, and serum cardiac troponin I (cTnI) concentrations were evaluated. Serologic assays and PCR determined the exposure and infection status for E. canis, Anaplasma spp., Babesia canis vogeli, Bartonella spp., Borrelia burgdorferi, Dirofilaria immitis, Ehrlichia chaffeensis, Ehrlichia ewingii, Leishmania chagasi, and spotted-fever group Rickettsia. Dogs were assigned to groups according to PCR status: E. canis infected, infected with other vector-borne organisms, sick dogs lacking PCR evidence for infection, and healthy controls. Results: E. canis -infected dogs had higher serum cTnI concentrations than controls (median: 0.04 ng/dL; range 0.04,9.12 ng/dL; control median: 0.04 ng/dL; range: 0.04,0.10 ng/dL; P= .012), and acute E. canis infection was associated with myocardial injury (odds ratio [OR]: 2.67, confidence interval [CI] 95%: 1.12,6.40, P= .027). Severity of anemia was correlated with increased risk of cardiomyocyte damage (r= 0.84, P < .001). Dogs with clinical signs of systemic inflammatory response syndrome (SIRS) were at higher risk for myocardial injury than were other sick dogs (OR: 2.55, CI 95%: 1.31,4.95, P= .005). Conclusions and Clinical Importance: Acute infection with E. canis is a risk factor for myocardial injury in naturally infected Brazilian dogs. Severity of anemia and SIRS might contribute to the pathophysiology of myocardial damage. [source]


    Negative interference of bilirubin and hemoglobin in the MEIA troponin I assay but not in the MEIA CK‐MB assay

    JOURNAL OF CLINICAL LABORATORY ANALYSIS, Issue 2 2001
    Amitava Dasgupta
    Abstract Troponin I is a sensitive and specific marker for the diagnosis of myocardial infarction. Several commercially available immunoassays measure the concentration of troponin I in serum. The microparticle enzyme immunoassay (MEIA) for troponin I (Abbott Laboratories, Abbott Park, IL) is widely used in clinical laboratories, including our hospital laboratory. We studied the effect of bilirubin and hemolysis on the MEIA for troponin I and compared our assay with a newly available chemiluminescent assay (CLIA) for troponin I (Bayer Diagnostics, Tarrytown, NY). We also measured CK‐MB concentration using the MEIA CK‐MB assay. One serum pool was prepared by combining several specimens of one patient with elevated troponin I and with a diagnosis of myocardial infarction. Other serum pools were prepared by combining sera with similar troponin I values. All serum pools showed normal bilirubin concentrations and had no hemolysis. Then we supplemented aliquots of serum pools with various concentrations of bilirubin (5.0, 10.0, 15.0, and 20.0 mg/dL). After supplementation, troponin I concentrations were measured again using the MEIA and CLIA. We observed a statistically significant decrease in troponin I concentration in the presence of bilirubin with the MEIA. For example, in serum pool 1, the troponin I concentration was 16.3 (bilirubin: 0.8 mg/dL). In the presence of 5.0, 10.0, 15.0 and 20.0 mg/dL of added bilirubin, the cardiac troponin I concentrations were 13.9, 13.4, 13.3 and 13.0 ng/ml respectively. We observed similar negative interference of bilirubin in troponin I measurement by the MEIA in other pools. The troponin I value decreased slightly (not statistically significant) in one pool and did not change in two other pools in the presence of bilirubin when we measured troponin I concentration using the CLIA. Interestingly, bilirubin did not interfere with the MEIA CK‐MB assay. Moderate hemolysis did not have any effect on the troponin I assay using either the MEIA or CLIA. However, gross hemolysis (hemoglobin > 40 mg/dL) interfered with both assays for troponin I. J. Clin. Lab. Anal. 15:76–80, 2001. © 2001 Wiley‐Liss, Inc. [source]


    Cardiac Troponin I in Feline Hypertrophic Cardiomyopathy

    JOURNAL OF VETERINARY INTERNAL MEDICINE, Issue 5 2002
    William E. Hemdon
    Measurement of plasma cardiac troponin I concentration ([cTnI]) is a sensitive and specific means for detecting myocardial damage in many mammalian species. Studies have shown that [cTnI] increases rapidly after cardiomyocyte injury. The molecular structure of cTnl is highly conserved across species, and current assays developed for its detection in humans have been validated in many species. In this study, [cTnI] was quantified using a 2-site sandwich assay in plasma of healthy control cats (n = 33) and cats with moderate to severe hypertrophic cardiomyopathy (HCM) (n = 20). [cTnI] was significantly higher in cats with HCM (median, 0.66 ng/mL; range, 0.05,10.93 ng/mL) as compared with normal cats (median, <0.03 ng/mL; range, <0.03-0.16 ng/mL) (P < .0001). An increase in [cTnI] was also highly sensitive (sensitivity = 85%) and specific (specificity = 97%) for differentiating cats with moderate to severe HCM from normal cats. [cTnI] was weakly correlated with diastolic thickness of the left ventricular free wall (r2= .354; P= .009) but not with the diastolic thickness of the interventricular septum (P= .8467) or the left atrium: aorta ratio (P= .0652). Furthermore, cats with congestive heart failure at the time of cTnl analysis had a significantly higher [cTnI] than did cats that had never had heart failure and those whose heart failure was controlled at the time of analysis (P= .0095 and P= .0201, respectively). These data indicate that cats with HCM have ongoing myocardial damage. Although the origin of this damage is unknown, it most likely explains the replacement fibrosis that is consistently identified in cats with moderate to severe HCM. [source]


    Negative interference of bilirubin and hemoglobin in the MEIA troponin I assay but not in the MEIA CK‐MB assay

    JOURNAL OF CLINICAL LABORATORY ANALYSIS, Issue 2 2001
    Amitava Dasgupta
    Abstract Troponin I is a sensitive and specific marker for the diagnosis of myocardial infarction. Several commercially available immunoassays measure the concentration of troponin I in serum. The microparticle enzyme immunoassay (MEIA) for troponin I (Abbott Laboratories, Abbott Park, IL) is widely used in clinical laboratories, including our hospital laboratory. We studied the effect of bilirubin and hemolysis on the MEIA for troponin I and compared our assay with a newly available chemiluminescent assay (CLIA) for troponin I (Bayer Diagnostics, Tarrytown, NY). We also measured CK‐MB concentration using the MEIA CK‐MB assay. One serum pool was prepared by combining several specimens of one patient with elevated troponin I and with a diagnosis of myocardial infarction. Other serum pools were prepared by combining sera with similar troponin I values. All serum pools showed normal bilirubin concentrations and had no hemolysis. Then we supplemented aliquots of serum pools with various concentrations of bilirubin (5.0, 10.0, 15.0, and 20.0 mg/dL). After supplementation, troponin I concentrations were measured again using the MEIA and CLIA. We observed a statistically significant decrease in troponin I concentration in the presence of bilirubin with the MEIA. For example, in serum pool 1, the troponin I concentration was 16.3 (bilirubin: 0.8 mg/dL). In the presence of 5.0, 10.0, 15.0 and 20.0 mg/dL of added bilirubin, the cardiac troponin I concentrations were 13.9, 13.4, 13.3 and 13.0 ng/ml respectively. We observed similar negative interference of bilirubin in troponin I measurement by the MEIA in other pools. The troponin I value decreased slightly (not statistically significant) in one pool and did not change in two other pools in the presence of bilirubin when we measured troponin I concentration using the CLIA. Interestingly, bilirubin did not interfere with the MEIA CK‐MB assay. Moderate hemolysis did not have any effect on the troponin I assay using either the MEIA or CLIA. However, gross hemolysis (hemoglobin > 40 mg/dL) interfered with both assays for troponin I. J. Clin. Lab. Anal. 15:76–80, 2001. © 2001 Wiley‐Liss, Inc. [source]