Home About us Contact | |||
Hysteretic Behaviour (hysteretic + behaviour)
Selected AbstractsCyclic tests on steel and concrete-filled tube frames with Slit WallsEARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS, Issue 6 2007Toko Hitaka Abstract Cyclic loading tests were performed on three one-storey steel frames and four three-storey concrete-filled tube (CFT) moment frames reinforced with a new type of earthquake-resisting element consisting of a steel plate shear wall with vertical slits. In this shear wall system, the steel plate segments between the slits behave as a series of flexural links, which provide fairly ductile response without the need for heavy stiffening of the wall. The steel shear walls and the moment frames behaved in a ductile manner up to more than 4% drift without abrupt strength degradation or loss of axial resistance. Results of these tests and complementary analysis provide a basis for an equivalent brace model to be employed in commercially available frame analysis programs. Test and analytical results suggest that the horizontal force is carried by the bolts in the middle portion of the wall,frame connection, while the vertical forces coupled with the moment in the connection are resisted by the bolts in the edge portion of the connection, for which the friction bolts in the connection should be designed. When sufficient transverse stiffening is provided, full plastic strength and non-degrading hysteretic behaviour can be achieved for this new type of shear wall. Copyright © 2006 John Wiley & Sons, Ltd. [source] Evaluation of residual drift demands in regular multi-storey frames for performance-based seismic assessmentEARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS, Issue 13 2006Jorge Ruiz-García Abstract This paper summarizes results of a comprehensive analytical study aimed at evaluating the amplitude and heightwise distribution of residual drift demands in multi-storey moment-resisting frames after earthquake excitation. For that purpose, a family of 12 one-bay two-dimensional generic frame models was subjected to an ensemble of 40 ground motions scaled to different intensities. In this investigation, an inelastic ground motion intensity measure was employed to scale each record, which allowed reducing the record-to-record variability in the estimation of residual drift demands. The results were statistically processed in order to evaluate the influence of ground motion intensity, number of stories, period of vibration, frame mechanism, system overstrength, and hysteretic behaviour on central tendency of residual drift demands. In addition, a special emphasis was given to evaluate the uncertainty in the estimation of residual drift demands. Results of incremental dynamic analyses indicate that the amplitude and heightwise distribution of residual drift demands strongly depends on the frame mechanism, the heightwise system structural overstrength and the component hysteretic behaviour. An important conclusion for performance-based assessment is that the evaluation of residual drift demands involves significantly larger levels of uncertainty (i.e. record-to-record variability) than that of maximum drift demands, which suggests that this variability and corresponding uncertainty should be explicitly taken into account when estimating residual drift demands during performance-based seismic assessment of frame buildings. Copyright © 2006 John Wiley & Sons, Ltd. [source] Residual displacement ratios for assessment of existing structuresEARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS, Issue 3 2006Jorge Ruiz-García Abstract Results of an analytical study aimed at evaluating residual displacement ratios, Cr, which allow the estimation of residual displacement demands from maximum elastic displacement demands is presented. Residual displacement ratios were computed using response time-history analyses of single-degree-of-freedom systems having 6 levels of relative lateral strength when subjected to an ensemble of 240 earthquake ground motions recorded in stations placed on firm sites. The results were statistically organized to evaluate the influence of the following parameters: period of vibration, level of relative lateral strength, site conditions, earthquake magnitude, and distance to the source. In addition, the influence of post-yield stiffness ratio in bilinear systems and of the unloading stiffness in stiffness-degrading systems was also investigated. A special emphasis is given to the uncertainty of these ratios. From this study, it is concluded that mean residual displacement ratios are more sensitive to changes in local site conditions, earthquake magnitude, distance to the source range and hysteretic behaviour than mean inelastic displacement ratios. In particular, residual displacement ratios exhibit large levels of record-to-record variability and, therefore, this dispersion should be taken into account when estimating residual displacements. A simplified expression is presented to estimate mean residual displacements ratios for elastoplastic systems during the evaluation of existing structures built on firm soil sites. Copyright © 2005 John Wiley & Sons, Ltd. [source] Cyclic tests on large-scale models of existing bridge piers with rectangular hollow cross-sectionEARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS, Issue 13 2003A. V. Pinto Abstract Cyclic tests on two large-scale models of existing bridge piers with rectangular hollow cross-section were performed in the ELSA laboratory. The prototype structure is an existing reinforced concrete highway bridge constructed in Austria in 1975. The piers presented several seismic deficiencies and consequently they showed poor hysteretic behaviour and limited deformation capacity as well as undesirable failure modes that do not comply with the requirements of modern codes for seismic-resistant structures. Experimental data are compared to numerical and empirical predictions. Copyright © 2003 John Wiley & Sons, Ltd. [source] Design of bilinear hysteretic isolation systemsEARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS, Issue 9 2003M. Fragiacomo Abstract This paper concerns the design of passive base isolation systems characterized by a bilinear hysteretic behaviour. The study refers to the case where the structure to be isolated (superstructure) vibrates according to the first mode. In this case the whole isolated structure can be modelled by a two-degree-of-freedom system. The base isolation effectiveness has been evaluated for different characteristics of the device, namely mass, strength, elastic and plastic stiffness, by using mainly energetic quantities. The optimum values for the base device have been obtained by minimizing the input energy and the displacement of the superstructure. Conclusions are drawn for superstructures with a fundamental period of 0.5s, a damping ratio of 5% and for three different kinds of earthquake ground motions. The study showed that the seismic input greatly affects the behaviour of the isolated structure, and therefore the design ground motion must be carefully chosen, dependent on the characteristics of the site. A simple procedure that involves mainly linear dynamic analyses is proposed for the design of base devices used in conjunction with superstructures of any fundamental vibration period. The procedure produces good results in spite of its simplicity, and therefore it is suitable for practical use by design engineers. Copyright © 2003 John Wiley & Sons, Ltd. [source] An energetic material model for time-dependent ferroelectric behaviour: existence and uniquenessMATHEMATICAL METHODS IN THE APPLIED SCIENCES, Issue 12 2006Alexander Mielke Abstract We discuss rate-independent engineering models for the multi-dimensional behaviour of ferroelectric materials. These models capture the non-linear and hysteretic behaviour of such materials. We show that these models can be formulated in an energetic framework which is based on the elastic and the electric displacements as reversible variables and on interior, irreversible variables like the remanent polarization. We provide quite general conditions on the constitutive laws which guarantee the existence of a solution. Under more restrictive assumptions we are also able to establish uniqueness results. Copyright © 2006 John Wiley & Sons, Ltd. [source] Experimentelle Bestimmung der hygrischen Sorptionsisotherme und des Feuchtetransportes unter instationären BedingungenBAUPHYSIK, Issue 2 2006Assistent und Laborleiter Rudolf Plagge Dr.-Ing. Mit der vorgestellten Augenblicksprofil-Methode (APM) werden sowohl die relative Luftfeuchte und die Temperatur, als auch der volumetrische Wassergehalt in bestimmten Positionen in einem porösen Material bestimmt. Die Messungen werden kontinuierlich unter instationären Bedingungen durchgeführt. Damit erlaubt die APM eine dynamische und gleichzeitige Messung der hygroskopischen Sorptionsisotherme und der hygrischen Feuchteleitfähigkeit für einzelne Kompartimente innerhalb der Materialprobe. Die Feuchteleitfähigkeit wird aus den sich zeitlich ändernden Potentialgradienten und den dazugehörigen Feuchteverteilungen für die jeweiligen Kompartimente berechnet. Die Anwendung nicht konstanter Randbedingungen in der APM erlaubt die Untersuchung des hygrodynamischen Verhaltes von porösen Materialien. In der vorliegenden Studie werden die zeit- und prozeßabhängige Feuchtespeicherung und der Feuchtetransport bestimmt. Die vorgestellten Adsorptions- und Desorptionsexperimente wurden an dem kapillar- aktiven Wärmedämmstoff Calciumsilikat durchgeführt. Die Ergebnisse geben das Hystereseverhalten und den Einfluß der Dynamik der Prozesse wider. In Positionen mit schnellen Feuchteänderungen wird die Feuchtespeicherfunktion im Vergleich mit Regionen langsamer Feuchteänderung nach oben verschoben. Die Feuchteleitfähigkeit als Funktion der relativen Luftfeuchte zeigt eine bedeutende Hysterese. Hingegen ist die Feuchteleitfähigkeit in Relation zum Wassergehalt nicht hysteretisch. (© 2006 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim) Experimental determination of the hygroscopie sorption isotherm and the moisture conductvity under transient conditions. By means of the proposed Instantaneous Profile Method (IPM) the relative humidity or the capillary pressure as well as the volumetric water content at specific locations inside a porous medium can be determined. The measurements are carried out under transient conditions and continuously in time. Thus, the IPM allows dynamic measurements of the hygroscopic sorption isotherm and the hygroscopic moisture conductivity. In addition, the moisture conductivity can be obtained via calculation of the moisture flow distribution from the temporal change of moisture contents in the compartments of the sample. The application of non-constant boundary conditions in the IPM allows investigation of the hygrodynamic behaviour of porous materials. In the presented study, the time and process dependent moisture retention characteristic and moisture conductivity are determined. The adsorption and successive desorption experiments presented here have been performed on the capillary active insulation material Calcium Silicate. The results show a hysteretic behaviour with a pregnant influence of the process dynamics. At locations with a rapid moisture increase, the moisture retention characteristic is shifted up in comparison to regions with slow moisture change. The moisture conductivity as function of relative humidity shows a remarkable hysteresis. However, the moisture conductivity in relation to the water content turned out to be non-hysteretic. [source] Ground motion duration effects on nonlinear seismic responseEARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS, Issue 1 2006Iunio Iervolino Abstract The study presented in this paper addresses the question of which nonlinear demand measures are sensitive to ground motion duration by statistical analyses of several case studies. A number of single degree of freedom (SDOF) structures were selected considering: (1) four oscillation periods; (2) three evolutionary and non-evolutionary hysteretic behaviours; (3) two target ductility levels. Effects of duration are investigated, by nonlinear dynamic analysis, with respect to six different demand indices ranging from displacement ductility ratio to equivalent number of cycles. Input is made of six real accelerogram sets representing three specific duration scenarios (small, moderate and large duration). For all considered demand quantities time-history results are formally compared by statistical hypothesis test to asses the difference, if any, in the demand concerning different scenarios. Incremental dynamic analysis curves are used to evaluate duration effect as function of ground motion intensity (e.g. spectral acceleration corresponding to the SDOF's oscillation period). Duration impact on structural failure probability is evaluated by fragility curves. The results lead to the conclusion that duration content of ground motion is statistically insignificant to displacement ductility and cyclic ductility demand. The conclusions hold regardless of SDOF's period and hysteretic relationship investigated. Copyright © 2005 John Wiley & Sons, Ltd. [source] |