Home About us Contact | |||
High-resolution Ultrasound (high-resolution + ultrasound)
Selected AbstractsTest Characteristics of High-Resolution Ultrasound in the Preoperative Assessment of Margins of Basal Cell and Squamous Cell Carcinoma in Patients Undergoing Mohs Micrographic SurgeryDERMATOLOGIC SURGERY, Issue 1 2009ANOKHI JAMBUSARIA-PAHLAJANI MD BACKGROUND Noninvasive techniques to assess subclinical spread of nonmelanoma skin cancer (NMSC) may improve surgical precision. High-resolution ultrasound has shown promise in evaluating the extent of NMSC. OBJECTIVES To determine the accuracy of high-resolution ultrasound to assess the margins of basal cell (BCC) and squamous cell carcinomas (SCC) before Mohs micrographic surgery (MMS). METHODS We enrolled 100 patients with invasive SCC or BCC. Before the first stage of MMS, a Mohs surgeon delineated the intended surgical margin. Subsequently, a trained ultrasound technologist independently evaluated disease extent using the EPISCAN I-200 to evaluate tumor extent beyond this margin. The accuracy of high-resolution ultrasound was subsequently tested by comparison with pathology from frozen sections. RESULTS The test characteristics of the high-resolution ultrasound were sensitivity=32%, specificity=88%, positive predictive value=47%, and negative predictive value=79%. Subgroup analyses demonstrated better test characteristics for tumors larger than the median (area>1.74 cm2). Qualitative analyses showed that high-resolution ultrasound was less likely to identify extension from tumors with subtle areas of extension, such as small foci of dermal invasion from infiltrative SCC and micronodular BCC. CONCLUSION High-resolution ultrasound requires additional refinements to improve the preoperative determination of tumor extent before surgical treatment of NMSC. [source] Association between plasma osteoprotegerin concentrations and urinary albumin excretion in Type 2 diabetesDIABETIC MEDICINE, Issue 4 2009G. D. Xiang Abstract Aims Osteoprotegerin (OPG) is a recently identified inhibitor of bone resorption. Recent studies indicate that OPG is also associated with endothelial dysfunction in Type 2 diabetes. The aim was to investigate the relationship between plasma OPG levels and urinary albumin excretion (UAE) in Type 2 diabetic patients. Methods This study included 154 newly diagnosed Type 2 diabetic patients and 46 healthy subjects. Plasma OPG and 24-h UAE were measured. High-resolution ultrasound was used to measure flow-mediated (endothelium-dependent arterial) dilation (FMD). Results Compared with the normoalbuminuric subgroup, OPG levels in the microalbuminuric subgroup were significantly higher, and OPG levels in macroalbuminuria subgroup were significantly higher than those in the normoalbuminuria and albuminuria subgroups. Multiple regression analysis showed that only FMD (r = ,0.26), C-reactive protein (r = 0.23), fasting blood glucose (r = 0.25), 2-h blood glucose (r = 0.21), HbA1c (r = 0.28), UAE (r = 0.27) and retinopathy (r = 0.27) were significant factors associated with OPG. Pearson's correlation analyses showed a positive correlation between OPG and logUAE (r = 0.440) and negative correlations between OPG and FMD (r = ,0.284), and between FMD and logUAE (r = ,0.602). Conclusions Plasma OPG levels are significantly associated with UAE in Type 2 diabetic patients. [source] Use of High-Frequency, High-Resolution Ultrasound Before Mohs SurgeryDERMATOLOGIC SURGERY, Issue 6 2010ELLEN S. MARMUR MD BACKGROUND Although ultrasound imaging is employed ubiquitously today, its use to examine and assess the skin is a relatively new technology. We explored the clinical application and use of high-frequency, high-resolution ultrasound in Mohs micrographic surgery. OBJECTIVE To evaluate the ability of ultrasound to accurately determine lesion length and width of tumor borders in order to reduce the number of surgical stages. METHODS AND MATERIALS This was an institutional review board,approved single-center study of 26 Mohs surgery patients. Ultrasound images were taken to record lesion dimensions, and then the investigator documented clinical estimation of the first stage. Extirpation of the tumor and histological analysis were performed thereafter. RESULTS The results of 20 patients were included in the analysis. A paired-samples t -test revealed no significant difference between clinical and ultrasound widths (t=,1.324, p=.20). Similarly, there was no significant difference between the lengths found from clinical assessment and ultrasound (t=,1.093, p=.29). For different tumor types, there was no significant difference between clinical and ultrasound widths or lengths for basal cell carcinoma (t=,1.307, p=.23; t=,1.389, p=.20) or squamous cell cancer (t=,0.342, p=.73; t=0.427, p=.68). CONCLUSION There is a diagnostic role for high-resolution ultrasound in Mohs surgery regarding the delineation of surgical margins, but its limitations preclude its practical adoption at this time. The ultrasound equipment was loaned to the investigators. Funding for the study was provided by Longport, Inc. [source] Test Characteristics of High-Resolution Ultrasound in the Preoperative Assessment of Margins of Basal Cell and Squamous Cell Carcinoma in Patients Undergoing Mohs Micrographic SurgeryDERMATOLOGIC SURGERY, Issue 1 2009ANOKHI JAMBUSARIA-PAHLAJANI MD BACKGROUND Noninvasive techniques to assess subclinical spread of nonmelanoma skin cancer (NMSC) may improve surgical precision. High-resolution ultrasound has shown promise in evaluating the extent of NMSC. OBJECTIVES To determine the accuracy of high-resolution ultrasound to assess the margins of basal cell (BCC) and squamous cell carcinomas (SCC) before Mohs micrographic surgery (MMS). METHODS We enrolled 100 patients with invasive SCC or BCC. Before the first stage of MMS, a Mohs surgeon delineated the intended surgical margin. Subsequently, a trained ultrasound technologist independently evaluated disease extent using the EPISCAN I-200 to evaluate tumor extent beyond this margin. The accuracy of high-resolution ultrasound was subsequently tested by comparison with pathology from frozen sections. RESULTS The test characteristics of the high-resolution ultrasound were sensitivity=32%, specificity=88%, positive predictive value=47%, and negative predictive value=79%. Subgroup analyses demonstrated better test characteristics for tumors larger than the median (area>1.74 cm2). Qualitative analyses showed that high-resolution ultrasound was less likely to identify extension from tumors with subtle areas of extension, such as small foci of dermal invasion from infiltrative SCC and micronodular BCC. CONCLUSION High-resolution ultrasound requires additional refinements to improve the preoperative determination of tumor extent before surgical treatment of NMSC. [source] Endothelial dysfunction in Buerger's disease and its relation to markers of inflammationEUROPEAN JOURNAL OF CLINICAL INVESTIGATION, Issue 6 2006M. Joras Abstract Background, Buerger's disease (BD) is a segmental occlusive vascular disease. The aim of this study was to detect functional changes in brachial artery and asymptomatic morphological changes in extra-cranial carotid arteries not affected by the disease process and to assess markers of inflammation and endothelial damage. Materials and methods, Fourteen patients in the remission phase of BD and the same number of age- and sex-matched healthy controls were included in the study. The capability of endothelium-dependent (flow-mediated) and endothelium-independent dilation of the brachial artery and intima-media thickness of the carotid arteries were measured using high-resolution ultrasound. Laboratory parameters of endogenous fibrinolytic activity, inflammation and endothelial dysfunction were also measured. Results, Patients with BD had a diminished capability of endothelium-dependent vasodilation and higher levels of some circulating markers of inflammation, such as leukocytes, C-reactive protein, intercellular adhesion molecule-1 and E-selectin. Intercellular adhesion molecule-1 levels were related to some of the inflammatory markers (sedimentation rate, C-reactive protein, ,2-globulins and fibrinogen), while E-selectin was correlated with decreased endogenous blood fibrinolytic activity. Endothelium-dependent vasodilation was in negative correlation with the relative share of neutrophil granulocytes. There were no significant differences in intima-media thickness between patients with BD and controls. Conclusions, Our study has expressed generalized functional arterial disorder in patients with BD not accompanied by any measurable morphological changes of the carotid arterial wall. Functional deterioration of brachial artery could be related to increased levels of various inflammatory markers , the process which is most probably the basic pathogenetic mechanism of the disease. [source] Sonography versus nerve conduction studies in patients referred with a clinical diagnosis of carpal tunnel syndromeJOURNAL OF CLINICAL ULTRASOUND, Issue 7 2009D. Pastare MD Abstract Purpose. To compare the diagnostic value of high-resolution ultrasound (US) with nerve conduction studies (NCS) in patients with clinically defined carpal tunnel syndrome (CTS). Methods. A prospective study was conducted on 66 consecutive patients investigated for sensory hand symptoms. The gold standard was the clinical diagnosis of CTS. Results. NCS showed greater diagnostic sensitivity (82%) than US (62%) in supporting a diagnosis of CTS. With increasing neurophysiologic severity of median neuropathy, there was increasing convergence of the two test methods. Abnormal US as the only diagnostic supportive evidence of CTS was rare. However, the positive predictive value of US for CTS was 100%. Conclusion. NCS show better sensitivity than US in supporting a diagnosis of CTS. However, because of its high positive predictive value, one may consider using US as a screening test, eliminating the need for NCS in the majority of clinical suspicion of CTS and reserving NCS for cases in which US is negative. © 2009 Wiley Periodicals, Inc. J Clin Ultrasound, 2009 [source] In Vivo mouse imaging and spectroscopy in drug discoveryNMR IN BIOMEDICINE, Issue 3 2007Nicolau Beckmann Abstract Imaging modalities such as micro-computed tomography (micro-CT), micro-positron emission tomography (micro-PET), high-resolution MRI, optical imaging, and high-resolution ultrasound have become invaluable tools in preclinical pharmaceutical research. They can be used to non-invasively investigate, in vivo, rodent biology and metabolism, disease models, and pharmacokinetics and pharmacodynamics of drugs. The advantages and limitations of each approach usually determine its application, and therefore a small-rodent imaging laboratory in a pharmaceutical environment should ideally provide access to several techniques. In this paper we aim to illustrate how these techniques may be used to obtain meaningful information for the phenotyping of transgenic mice and for the analysis of compounds in murine models of disease. Copyright © 2007 John Wiley & Sons, Ltd. [source] The making of fetal surgeryPRENATAL DIAGNOSIS, Issue 7 2010Jan A. Deprest Abstract Fetal diagnosis prompts the question for fetal therapy in highly selected cases. Some conditions are suitable for in utero surgical intervention. This paper reviews historically important steps in the development of fetal surgery. The first invasive fetal intervention in 1963 was an intra-uterine blood transfusion. It took another 20 years to understand the pathophysiology of other candidate fetal conditions and to develop safe anaesthetic and surgical techniques before the team at the University of California at San Francisco performed its first urinary diversion through hysterotomy. This procedure would be abandoned as renal and pulmonary function could be just as effectively salvaged by ultrasound-guided insertion of a bladder shunt. Fetoscopy is another method for direct access to the feto-placental unit. It was historically used for fetal visualisation to guide biopsies or for vascular access but was also abandoned following the introduction of high-resolution ultrasound. Miniaturisation revived fetoscopy in the 1990s, since when it has been successfully used to operate on the placenta and umbilical cord. Today, it is also used in fetuses with congenital diaphragmatic hernia (CDH), in whom lung growth is triggered by percutaneous tracheal occlusion. It can also be used to diagnose and treat urinary obstruction. Many fetal interventions remain investigational but for a number of conditions randomised trials have established the role of in utero surgery, making fetal surgery a clinical reality in a number of fetal therapy programmes. The safety of fetal surgery is such that even non-lethal conditions, such as myelomeningocoele repair, are at this moment considered a potential indication. This, as well as fetal intervention for CDH, is currently being investigated in randomised trials. Copyright © 2010 John Wiley & Sons, Ltd. [source] A new non-invasive ultrasonic method for simultaneous measurements of longitudinal and radial arterial wall movements: first in vivo trialCLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, Issue 5 2003Magnus Persson Summary During recent years, the radial movement of the arterial wall has been extensively studied, and measurements of the radial movement are now an important tool in cardiovascular research for characterizing the mechanical properties of the arterial wall. In contrast, the longitudinal movement of vessels has gained little or no attention as it has been presumed that this movement is negligible. With modern high-resolution ultrasound, it can, however, be seen that the intima-media complex of the arterial wall moves not only in the radial direction, but also in the longitudinal direction during pulse-wave propagation. This paper describes a new non-invasive ultrasonic method that is able to measure simultaneously two dimensionally arterial vessel wall movements. The method is demonstrated in a limited in vivo trial. Results from the in vivo trial show that, apart from the well-known radial movement, there is a distinct longitudinal movement in the human common carotid artery with, in this case, the intima-media complex moving substantially as compared with the region of the tunica adventitia. Two-dimensional evaluation of the vessel-wall movements, taking not only the radial movement, but also the longitudinal movement into account, may provide novel information of importance in the evaluation of vessel-wall function. [source] |