Amplitude Threshold (amplitude + threshold)

Distribution by Scientific Domains


Selected Abstracts


Optimization of sigma amplitude threshold in sleep spindle detection

JOURNAL OF SLEEP RESEARCH, Issue 4 2000
E. Huupponen
Sleep spindles are transient EEG waveforms of non-rapid eye movement sleep. There is considerable intersubject variability in spindle amplitudes. The problem in automatic spindle detection has been that, despite this fact, a fixed amplitude threshold has been used. Selection of the spindle detection threshold value is critical with respect to the sensitivity of spindle detection. In this study a method was developed to estimate the optimal recording-specific threshold value for each all-night recording without any visual scorings. The performance of the proposed method was validated using four test recordings each having a very different number of visually scored spindles. The optimal threshold values for the test recordings could be estimated well. The presented method seems very promising in providing information about sleep spindle amplitudes of individual all-night recordings. [source]


Philips QT Interval Measurement Algorithms for Diagnostic, Ambulatory, and Patient Monitoring ECG Applications

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2009
F.A.C.C., Sophia H. Zhou Ph.D.
Background: Commonly used techniques for QT measurement that identify T wave end using amplitude thresholds or the tangent method are sensitive to baseline drift and to variations of terminal T wave shape. Such QT measurement techniques commonly underestimate or overestimate the "true" QT interval. Methods: To find the end of the T wave, the new Philips QT interval measurement algorithms use the distance from an ancillary line drawn from the peak of the T wave to a point beyond the expected inflection point at the end of the T wave. We have adapted and optimized modifications of this basic approach for use in three different ECG application areas: resting diagnostic, ambulatory Holter, and in-hospital patient monitoring. The Philips DXL resting diagnostic algorithm uses an alpha-trimming technique and a measure of central tendency to determine the median QT value of eight most reliable leads. In ambulatory Holter ECG analysis, generally only two or three channels are available. QT is measured on a root-mean-square vector magnitude signal. Finally, QT measurement in the real time in-hospital application is among the most challenging areas of QT measurement. The Philips real time QT interval measurement algorithm employs features from both Philips DXL 12-lead and ambulatory Holter QT algorithms with further enhancements. Results: The diagnostic 12-lead algorithm has been tested against the gold standard measurement database established by the CSE group with results surpassing the industrial ECG measurement accuracy standards. Holter and monitoring algorithm performance data on the PhysioNet QT database were shown to be similar to the manual measurements by two cardiologists. Conclusion: The three variations of the QT measurement algorithm we developed are suitable for diagnostic 12-lead, Holter, and patient monitoring applications. [source]


Noninvasive Activity-based Control of an Implantable Rotary Blood Pump: Comparative Software Simulation Study

ARTIFICIAL ORGANS, Issue 2 2010
Dean M. Karantonis
Abstract A control algorithm for an implantable centrifugal rotary blood pump (RBP) based on a noninvasive indicator of the implant recipient's activity level has been proposed and evaluated in a software simulation environment. An activity level index (ALI),derived from a noninvasive estimate of heart rate and the output of a triaxial accelerometer,forms the noninvasive indicator of metabolic energy expenditure. Pump speed is then varied linearly according to the ALI within a defined range. This ALI-based control module operates within a hierarchical multiobjective framework, which imposes several constraints on the operating region, such as minimum flow and minimum speed amplitude thresholds. Three class IV heart failure (HF) cases of varying severity were simulated under rest and exercise conditions, and a comparison with other popular RBP control strategies was performed. Pump flow increases of 2.54, 1.94, and 1.15 L/min were achieved for the three HF cases, from rest to exercise. Compared with constant speed control, this represents a relative flow change of 30.3, 19.8, and ,15.4%, respectively. Simulations of the proposed control algorithm exhibited the effective intervention of each constraint, resulting in an improved flow response and the maintenance of a safe operating condition, compared with other control modes. [source]