Home About us Contact | |||
Fluid Forces (fluid + force)
Selected AbstractsA control analysis of interaction problem by fluid forceINTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, Issue 7 2001Shoichiro Kato Abstract This paper presents a control analysis of displacement for a building. To control the vertical displacement of the building, control device of multi-balloons with water inside is introduced on the friction piles. Coupling through the water, soil, balloon and pile, the interaction problem is numerically solved. The soil is assumed to be a linear elastic body. The balloon and pile are also modelled as linear elastic truss and rigid-frame components. The water is assumed to be the two-dimensional incompressible Navier,Stokes flow. All components are discretized by the finite element method in space. The control analysis of vertical displacement by fluid force is performed for the purpose of keeping the building horizontal. One of the optimal control theory, the so-called Sakawa,Shindo method, is applied for the control analysis. Using this method, control flux of the water is determined so that position at the top of the balloon comes to be close to the objective position. Copyright © 2001 John Wiley & Sons, Ltd. [source] Multiple-relaxation-time lattice Boltzmann computation of channel flow past a square cylinder with an upstream control bi-partitionINTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, Issue 6 2010M. A. Moussaoui Abstract The present paper deals with the application of the multiple-relaxation-time lattice Boltzmann equation (MRT-LBE) for the simulation of a channel flow with a bi-partition located upstream of a square cylinder in order to control the flow. Numerical investigations have been carried out for different heights and positions of the bi-partition at Reynolds number of 250. Key computational issues involved are the computation of fluid forces acting on the square cylinder, the vortex shedding frequency and the impact of such bluff body on the flow pattern. A particular attention is paid to drag and lift coefficients on the square cylinder. The predicted results from MRT-LBE simulations show that in most cases, the interaction was beneficial insofar as the drag of the square block was lower with the bi-partition than without it. Fluctuating side forces due to vortex shedding from the main body were also reduced for most bi-partition positions. Copyright © 2009 John Wiley & Sons, Ltd. [source] The Importance of dQ/dt on the Flow Field in a Turbodynamic Pump With Pulsatile FlowARTIFICIAL ORGANS, Issue 9 2009Fangjun Shu Abstract Fluid dynamic analysis of turbodynamic blood pumps (TBPs) is often conducted under steady flow conditions. However, the preponderance of clinical applications for ventricular assistance involves unsteady, pulsatile flow,due to the residual contractility of the native heart. This study was undertaken to demonstrate the importance of pulsatility and the associated time derivative of the flow rate (dQ/dt) on hemodynamics within a clinical-scale TBP. This was accomplished by performing flow visualization studies on a transparent model of a centrifugal TBP interposed within a cardiovascular simulator with controllable heart rate and stroke volume. Particle image velocimetry triggered to both the rotation angle of the impeller and phase of the cardiac cycle was used to quantify the velocity field in the outlet volute and in between the impeller blades for 16 phases of the cardiac cycle. Comparison of the unsteady flow fields to corresponding steady conditions at the same (instantaneous) flow rates revealed marked differences. In particular, deceleration of flow was found to promote separation within the outlet diffuser, while acceleration served to stabilize the velocity field. The notable differences between the acceleration and deceleration phases illustrated the prominence of inertial fluid forces. These studies emphasize the importance of dQ/dt as an independent variable for thorough preclinical validation of TBPs intended for use as a ventricular assist device. [source] Numerical and Experimental Analysis of an Axial Flow Left Ventricular Assist Device: The Influence of the Diffuser on Overall Pump PerformanceARTIFICIAL ORGANS, Issue 7 2005Alexandrina Untaroiu Abstract:, Thousands of adult cardiac failure patients may benefit from the availability of an effective, long-term ventricular assist device (VAD). We have developed a fully implantable, axial flow VAD (LEV-VAD) with a magnetically levitated impeller as a viable option for these patients. This pump's streamlined and unobstructed blood flow path provides its unique design and facilitates continuous washing of all surfaces contacting blood. One internal fluid contacting region, the diffuser, is extremely important to the pump's ability to produce adequate pressure but is challenging to manufacture, depending on the complex blade geometries. This study examines the influence of the diffuser on the overall LEV-VAD performance. A combination of theoretical analyses, computational fluid (CFD) simulations, and experimental testing was performed for three different diffuser models: six-bladed, three-bladed, and no-blade configuration. The diffuser configurations were computationally and experimentally investigated for flow rates of 2,10 L/min at rotational speeds of 5000,8000 rpm. For these operating conditions, CFD simulations predicted the LEV-VAD to deliver physiologic pressures with hydraulic efficiencies of 15,32%. These numerical performance results generally agreed within 10% of the experimental measurements over the entire range of rotational speeds tested. Maximum scalar stress levels were estimated to be 450 Pa for 6 L/min at 8000 rpm along the blade tip surface of the impeller. Streakline analysis demonstrated maximum fluid residence times of 200 ms with a majority of particles exiting the pump in 80 ms. Axial fluid forces remained well within counter force generation capabilities of the magnetic suspension design. The no-bladed configuration generated an unacceptable hydraulic performance. The six-diffuser-blade model produced a flow rate of 6 L/min against 100 mm Hg for 6000 rpm rotational speed, while the three-diffuser-blade model produced the same flow rate and pressure rise for a rotational speed of 6500 rpm. The three-bladed diffuser configuration was selected over the six-bladed, requiring only an incremental adjustment in revolution per minute to compensate for and ease manufacturing constraints. The acceptable results of the computational simulations and experimental testing encourage final prototype manufacturing for acute and chronic animal studies. [source] Performance of Dual-Media Expanded Bed BioreactorASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, Issue 5-6 2005R. Abdul-Rahman Abstract Adsorption and biological treatment are two possible approaches to remove chloro-organic and organic compounds. Granular activated carbon (GAC) biofilm reactors combine these two features, the adsorptive capacity and irregular shape of GAC particles providing niches for bacterial colonisation protected from high fluid forces, while the variety of functional groups on the surface enhance the attachment of microorganisms. The biofilm process is compact and offers reactions in both aerobic and anoxic states. Studies on removal of nitrogen constituents by a biofilm process were carried out using a dual-media expanded bed bioreactor, with GAC and plastic media as support media. The plastic media also acts as a filter for the effluent. Experiments were carried out at F:M of about 0.45 and hydraulic residence times (HRT) of 48, 24 and 12 hours. Bed expansion was maintained at 20,30% by recirculation flow. Aerobic condition was maintained at dissolved oxygen (DO) of about 2 mg/l throughout the bed. Chemical oxygen in demand (COD) in feed was 1000 mg/L while the total-N was 100 mg/L. Analysis showed that the process is able to maintain very stable conditions, achieving substantial COD removal of about 85% and total-N removal of about 80%. Biofilm biomass measurements showed an increase from 400 mg/l at HRT of 48 hours to 10,100 mg/l at HRT 12 hours, showing that much higher biomass concentrations may be contained in a biofilm process as compared to a conventional suspended biomass process. Bioreactors contain their own ecosystems, the nature of the community and the state of microorganisms define the kinetics and determine reactor performance. Growth kinetic parameters obtained are YH = 0.3421 mg/mg, m,H = 0.2252 day,1, KH = 319.364 mg/l and bH = 0.046 day,1. The denitrification kinetic parameters obtained are YHD = 0.9409 mg/mg, m,HD = 0.1612 day,1, KHD = 24.6253 mg/l and bHD = 0.0248 day,1. These parameters enable prediction of required reactor sizes and operational parameters. The plastic media has greatly improved effluent clarification by 98% as compared to single-media (GAC) only reactor. [source] |