Floor Reconstruction (floor + reconstruction)

Distribution by Scientific Domains

Kinds of Floor Reconstruction

  • pelvic floor reconstruction


  • Selected Abstracts


    ORIGINAL RESEARCH,SURGERY: Short Term Impact on Female Sexual Function of Pelvic Floor Reconstruction with the Prolift Procedure

    THE JOURNAL OF SEXUAL MEDICINE, Issue 11 2009
    Tsung-Hsien Su MD
    ABSTRACT Introduction., The Prolift system is an effective and safe procedure using mesh reinforcement for vaginal reconstruction of pelvic organ prolapse (POP), but its effect on sexual function is unclear. Aim., To evaluate the impact of transvaginal pelvic reconstruction with Prolift on female sexual function at 6 months post-operatively. Methods., Thirty-three sexually active women who underwent Prolift mesh pelvic floor reconstruction for symptomatic POP were evaluated before and 6 months after surgery. Their sexual function was assessed by using the short form of the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12) before and after surgery. The quality of life was also evaluated with the short forms of the Urogenital Distress Inventory (UDI-6) and the Incontinence Impact Questionnaire (IIQ-7) as a control for efficacy of the procedure. The Pelvic Organ Prolapse Quantification system was used to evaluate the degree of prolapse. Main Outcome Measures., PISQ-12 scores at 6 months post-operatively. Results., The total PISQ-12 score decreased from 29.5 ± 9.0 to 19.3 ± 14.7 (P < 0.001), indicating worsening of sexual function 6 months post-operatively. The behavioral, physical, and partner-related domains of PISQ-12 were each significantly reduced (5.2 ± 3.7 vs. 2.9 ± 3.7, P = 0.016; 15.4 ± 4.7 vs. 10.4 ± 8.6, P = 0.001; 8.9 ± 3.8 vs. 6.4 ± 5.5, P = 0.01, respectively). UDI-6 and IIQ-7 scores were significantly improved at the 6-month follow-up, as was anatomic recovery. Of the 33 subjects, 24 (73%) had worse sexual function 6 months after the procedure. Conclusion., The Prolift procedure provided an effective anatomic cure of POP, but it had an adverse effect on sexual function at 6 months after surgery. Su TH, Lau HH, Huang WC, Chen SS, Lin TY, Hsieh CH, and Yeh CY. Short term impact on female sexual function of pelvic floor reconstruction with the Prolift procedure. J Sex Med 2009;6:3201,3207. [source]


    Zygomaticomaxillary buttress reconstruction of midface defects with the osteocutaneous radial forearm free flap

    HEAD & NECK: JOURNAL FOR THE SCIENCES & SPECIALTIES OF THE HEAD AND NECK, Issue 10 2008
    Patricio Andrades MD
    Abstract Background. The purpose of this study was to evaluate morbidity, functional, and aesthetic outcomes in midface zygomaticomaxillary buttress reconstruction using the osteocutaneous radial forearm free flap (OCRFFF). Methods. A retrospective review of 24 consecutive patients that underwent midface reconstruction using the OCRFFF was performed. All patients had variable extension of maxillectomy defects that requires restoration of the zygmatico-maxillary buttress. After harvest, the OCRFFF was fixed transversely with miniplates connecting the remaining zygoma to the anterior maxilla. The orbital support was given by titanium mesh when needed that was fixed to the radial forearm bone anteriorly and placed on the remaining orbital floor posteriorly. The skin paddle was used for intraoral lining, external skin coverage, or both. The main outcome measures were flap success, donor-site morbidity, orbital, and oral complications. Facial contour, speech understandability, swallowing, oronasal separation, and socialization were also analyzed. Results. There were 6 women and 18 men, with an average age of 66 years old (range, 34,87). The resulting defects after maxillectomy were (according to the Cordeiro classification; Disa et al, Ann Plast Surg 2001;47:612,619; Santamaria and Cordeiro, J Surg Oncol 2006;94:522,531): type I (8.3%), type II (33.3%), type III (45.8%), and type IV (12.5%). There were no flap losses. Donor-site complications included partial loss of the split thickness skin graft (25%) and 1 radial bone fracture. The most significant recipient-site complications were severe ectropion (24%), dystopia (8%), and oronasal fistula (12%). All the complications occurred in patients with defects that required orbital floor reconstruction and/or cheek skin coverage. The average follow-up was 11.5 months, and over 80% of the patients had adequate swallowing, speech, and reincorporation to normal daily activities. Conclusions. The OCRFFF is an excellent alternative for midface reconstruction of the zygomaticomaxillary buttress. Complications were more common in patients who underwent resection of the orbital rim and floor (type III and IV defects) or external cheek skin. © 2008 Wiley Periodicals, Inc. Head Neck, 2008 [source]


    Biomechanical findings in rats undergoing fascial reconstruction with graft materials suggested as an alternative to polypropylene ,,

    NEUROUROLOGY AND URODYNAMICS, Issue 3 2010
    M.L. Konstantinovic
    Abstract Aims Graft materials used for pelvic floor reinforcement should still be considered as investigational and, therefore, evaluated experimentally and within clinical trials. The present report describes our biomechanical findings in rats implanted with selected novel implant materials, which in recent years have been suggested as alternatives to plain polypropylene (PP) meshes. Methods Full thickness abdominal wall defects were primarily repaired by the implant of interest. Experiments involved eight different implant materials: two partly degradable synthetic implants, that is, a hybrid of polyglactin 910 with PP (Vypro II) and collagen coated PP (Pelvitex); two non-cross linked (Surgisis, InteX,n LP) and two cross-linked materials (Pelvicol, Pelvisoft) and two porous modifications of InteX,n LP and Pelvicol implants. At different time points (7, 14, 30, and 90 days), the implants and surrounding host tissue (explant) were harvested and tensiometry was performed. Tensile strength and location of breakage were recorded. Results In general resorbable non-cross linked collagen matrices and porous materials were weaker after 90 days; similar behavior was seen for implant materials alone and their construction with the surrounding native tissue. Both non-porous and porous modification of InteX,n LP appeared at 90 days as a very thin layer of collagen that was two-thirds, respectively one-third of the initial thickness. Conclusions In experimental conditions, sufficient strength was obtained only after 3 months, and PP containing constructs appeared as the strongest though reconstruction with Pelvicol showed comparable outcomes. Lower values for strength of non-cross linked and porous collagen materials are questioning their efficacy for pelvic floor reconstruction. Neurourol. Urodynam. 29:488,493, 2010. © 2009 Wiley-Liss, Inc. [source]


    Analysis of outcomes of single polypropylene mesh in total pelvic floor reconstruction,

    NEUROUROLOGY AND URODYNAMICS, Issue 1 2007
    Kaytan V. Amrute
    Abstract Aims A 2.5-year outcome analysis was performed on patients who underwent transvaginal repair of total pelvic organ prolapse with single polypropylene mesh. A description of the repair technique using a tension-free 4-point fixation is also reviewed. Methods After proper vaginal dissection, a specially fashioned "H" shaped polypropylene mesh is positioned and fixed at 4-points. With a single piece of mesh, the anterior arms provide mid-urethral and bladder neck support, the mid-portion of the mesh corrects anterior compartment defects, and the posterior arms aid in vaginal vault suspension. Initially, bone anchors were utilized for anterior fixation, but currently a tension-free method is used. A retrospective analysis using chart review was performed on 96 patients who underwent this procedure from January 2000 to June 2005. Additional information was gathered by a telephone survey using a questionnaire. Statistical analysis was performed using Student's t -test, with Sigma Stat®. Results Seventy-six patients (79%) were available with a mean follow-up time of 30.7,±, 1.7 months and mean age of 69.3,±,11.3. Among those with follow-up, 36 patients (47.4%) underwent concurrent hysterectomies. Recurrence of prolapse was reported by four patients (5.2%). Sixty-eight patients (89%) were completely dry or almost dry, defined as an occasional leak. For those with preoperative incontinence (n,=,36), average pad use per day decreased significantly from 2.1,±,0.4 to 0.8,±,0.2 (P,<,0.005) postoperatively. Twelve patients (15.7%) reported of de novo urgency. Six patients required reoperation including excision of vaginal mesh erosion (2), uretholysis for obstruction (1), removal of palpable vaginal suture (1), and recurrent SUI (2). Among the 21 patients who are sexually active, 19 denied any dyspareunia (90.4%). Patient satisfaction was high, as the mean value was 7.9,±,0.3 on a scale of 1 (least satisfied) to 10 (most satisfied). Conclusions Transvaginal repair of complete pelvic prolapse using polypropylene mesh is a safe and efficacious option, with minimal recurrence of prolapse and SUI. While two patients had vaginal erosions, no urethral or bladder erosions occurred. Patient satisfaction was overall favorable. Neurourol. Urodynam. © 2006 Wiley-Liss, Inc. [source]


    ORIGINAL RESEARCH,SURGERY: Short Term Impact on Female Sexual Function of Pelvic Floor Reconstruction with the Prolift Procedure

    THE JOURNAL OF SEXUAL MEDICINE, Issue 11 2009
    Tsung-Hsien Su MD
    ABSTRACT Introduction., The Prolift system is an effective and safe procedure using mesh reinforcement for vaginal reconstruction of pelvic organ prolapse (POP), but its effect on sexual function is unclear. Aim., To evaluate the impact of transvaginal pelvic reconstruction with Prolift on female sexual function at 6 months post-operatively. Methods., Thirty-three sexually active women who underwent Prolift mesh pelvic floor reconstruction for symptomatic POP were evaluated before and 6 months after surgery. Their sexual function was assessed by using the short form of the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12) before and after surgery. The quality of life was also evaluated with the short forms of the Urogenital Distress Inventory (UDI-6) and the Incontinence Impact Questionnaire (IIQ-7) as a control for efficacy of the procedure. The Pelvic Organ Prolapse Quantification system was used to evaluate the degree of prolapse. Main Outcome Measures., PISQ-12 scores at 6 months post-operatively. Results., The total PISQ-12 score decreased from 29.5 ± 9.0 to 19.3 ± 14.7 (P < 0.001), indicating worsening of sexual function 6 months post-operatively. The behavioral, physical, and partner-related domains of PISQ-12 were each significantly reduced (5.2 ± 3.7 vs. 2.9 ± 3.7, P = 0.016; 15.4 ± 4.7 vs. 10.4 ± 8.6, P = 0.001; 8.9 ± 3.8 vs. 6.4 ± 5.5, P = 0.01, respectively). UDI-6 and IIQ-7 scores were significantly improved at the 6-month follow-up, as was anatomic recovery. Of the 33 subjects, 24 (73%) had worse sexual function 6 months after the procedure. Conclusion., The Prolift procedure provided an effective anatomic cure of POP, but it had an adverse effect on sexual function at 6 months after surgery. Su TH, Lau HH, Huang WC, Chen SS, Lin TY, Hsieh CH, and Yeh CY. Short term impact on female sexual function of pelvic floor reconstruction with the Prolift procedure. J Sex Med 2009;6:3201,3207. [source]


    Management of isolated orbital floor blow-out fractures: a survey of Australian and New Zealand oral and maxillofacial surgeons

    CLINICAL & EXPERIMENTAL OPHTHALMOLOGY, Issue 1 2004
    Anthony J Lynham FRCS FRACDS(OMS)
    Abstract Background:,This is the first report of involvement of Australian and New Zealand oral and maxillofacial surgeons in the management of isolated orbital floor blow-out fractures and was conducted to obtain comparisons with the results from a recent similar survey of British oral and maxillofacial surgeons. Methods:,A questionnaire survey was sent to all 113 practising members of the Australian and New Zealand Association of Oral and Maxillofacial Surgeons in April 2002 with a second mailout 1 month later. Results:,Sixty-nine per cent of the respondents were referred isolated orbital floor blow-out fractures for manage­ment, and just over half of these respondents estimated that 50% or more of the cases went to surgery. The materials most commonly used in orbital floor reconstruction were resorbable membrane for small defects and autologous bone for large defects. Conclusion:,As in Britain, management of isolated orbital floor blow-out fractures comprises part of the surgical spectrum for many oral and maxillofacial surgeons in Australia and New Zealand. The management protocol was observed to be very similar between the two groups. [source]