Aggregation Tests (aggregation + test)

Distribution by Scientific Domains


Selected Abstracts


The erythrocyte adhesiveness/aggregation test for the detection of an acute phase response and for the assessment of its intensity

INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, Issue 4 2002
N. Maharshak
Summary We have developed a simple slide test and image analysis to reveal the state of erythrocyte adhesiveness/aggregation in the peripheral blood of patients with various degrees of the humoral acute phase response. The significant correlation between the results of the erythrocyte adhesiveness/aggregation test (EAAT), the erythrocyte sedimentation rate and fibrinogen concentration support the notion that it is possible to use the EAAT as a marker for the intensity of the acute phase response. Within a group of 860 individuals, we were able to differentiate effectively between groups of patients with a different intensity of humoral acute phase response. The present study confirms previous observations that support the applicability of the EAAT to routine clinical practice. [source]


Superiority of a functional leukocyte adhesiveness/aggregation test over the white blood cell count to discriminate between mild and significant inflammatory response in patients with acute bacterial infections

JOURNAL OF CLINICAL LABORATORY ANALYSIS, Issue 4 2002
Ori Rogowski
Abstract Electronic cell counters may underestimate the white blood cell count (WBCC) in the presence of aggregated leukocytes. In the present study we focused on the possibility of using a functional, as opposed to an anatomic, count to circumvent this eventual underestimation. A model of bacterial infection was used because of the importance of leukocytosis in the physician's clinical decision-making process. There were 35 patients with low C-reactive protein (CRP) concentrations (0.5,4.9 mg/dL), 45 with intermediate (5,9.9 mg/dL), and 120 with relatively high (>10 mg/dL) CRP concentrations. A significant (P=0.008) difference was noted between the state of leukocyte adhesiveness/aggregation in the peripheral blood of individuals with low CRP concentrations (3.5%±4.3%) and those with high CRP concentrations (7.4%±8%), while there was no significant difference in the respective number of WBCs per cubic millimeter (cmm) (11,600 ± 5,500 and 14,000 ± 7,200, respectively). We raise the possibility that a functional test might be superior over an anatomic count in patients with acute bacterial infection and a significant acute phase response. © 2002 Wiley-Liss, Inc. [source]


Glanzmann thrombasthenia and Bernard,Soulier syndrome in south Iran

INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, Issue 5 2005
A. AFRABIASI
Summary Glanzmann thrombasthenia (GT) and Bernard,Soulier syndrome (BSS) are two rare inherited disorders of platelet function. In this study, we report the demographic, clinical and biological characteristics of 23 patients with GT and of seven patients with BSS from southern Iran who had been followed for many years but fully characterized only recently, when platelet aggregation tests and flow cytometric studies became available for the first time in the country. We found a high prevalence of both diseases that can be explained by the high rate of consanguineous marriages in south Iran. Patients affected by GT and BSS suffer mainly from mucocutaneous bleedings causing anemia and transfusion requirements. [source]


Platelet concentrates transfusion in cardiac surgery and platelet function assessment by multiple electrode aggregometry

ACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 2 2009
N. RAHE-MEYER
Background: Platelet dysfunction contributes to the pathophysiology of bleeding complications during and after cardiac surgery. In most surgical institutions, no peri-operative point-of-care monitoring of platelet function is used. We evaluated the usefulness of the Multiplate® platelet function analyser based on impedance aggregometry for identifying groups of patients at a high risk of transfusion of platelet concentrates (PC). Methods: Platelet function parameters were determined in 60 patients before and after routine cardiac surgery. Impedance aggregometry measurements were performed on Multiplate® using ADP (ADPtest), collagen (COLtest) and thrombin receptor activating peptide (TRAPtest) as platelet activators. The correlations between the aggregometry results and the transfusion of PC were calculated. The results of the aggregation tests were also divided into tertiles and the differences in PC transfusion between the low and the high tertile were assessed. Results: Low aggregometry delimited groups of patients with significantly higher PC transfusion. In the receiver operating characteristic curve, low pre-operative aggregation in the ADPtest identified patients with high total transfusion of PC (area under the curve 0.74, P=0.001), while the ADPtest performed at the end of the operation identified patients with high PC transfusion on the intensive care unit (ICU) (area under the curve 0.76, P=0.002). Conclusions: Near-patient platelet aggregation may allow the identification of patients with enhanced risk of PC transfusion, both pre-operatively and upon arrival on the ICU. [source]


In Vivo Evaluation of Zirconia Ceramic in the DexAide Right Ventricular Assist Device Journal Bearing

ARTIFICIAL ORGANS, Issue 6 2010
Diyar Saeed
Abstract Zirconia is a ceramic with material properties ideal for journal bearing applications. The purpose of this study was to evaluate the use of zirconium oxide (zirconia) as a blood journal bearing material in the DexAide right ventricular assist device. Zirconia ceramic was used instead of titanium to manufacture the DexAide stator housing without changing the stator geometry or the remaining pump hardware components. Pump hydraulic performance, journal bearing reliability, biocompatibility, and motor efficiency data of the zirconia stator were evaluated in six chronic bovine experiments for 14,91 days and compared with data from chronic experiments using the titanium stator. Pump performance data including average in vivo pump flows and speeds using a zirconia stator showed no statistically significant difference to the average values for 16 prior titanium stator in vivo studies, with the exception of a 19% reduction in power consumption. Indices of hemolysis were comparable for both stator types. Results of coagulation assays and platelet aggregation tests for the zirconia stator implants showed no device-induced increase in platelet activation. Postexplant evaluation of the zirconia journal bearing surfaces showed no biologic deposition in any of the implants. In conclusion, zirconia ceramic can be used as a hemocompatible material to improve motor efficiency while maintaining hydraulic performance in a blood journal bearing application. [source]