Estimated Concentrations (estimated + concentration)

Distribution by Scientific Domains


Selected Abstracts


Determination of iodide in samples with complex matrices by hyphenation of capillary isotachophoresis and zone electrophoresis

ELECTROPHORESIS, Issue 20 2007
Pavla Pant
Abstract A method has been developed for the determination of iodide in mineral water, seawater, cooking salt, serum, and urine based on hyphenation of capillary ITP and zone electrophoresis. A commercially available instrumentation for capillary ITP with column-switching system was used. ITP served for removal of chloride present in the analyzed samples in a ratio of 106,107:1 to iodide, zone electrophoresis was used for evaluation. Isotachophoretic separation proceeded in a capillary made of fluorinated ethylene,propylene copolymer of 0.8,mm id and 90,mm total length to the bifurcation point filled with a leading electrolyte (LE) composed of 8,mM HCl,+,16,mM ,-alanine (,-Ala),+,10% PVP,+,2.86,mM N2H4×2HCl, pH,3.2; and a terminating electrolyte composed of 8,mM H3PO4,+,16,mM ,-Ala,+,10% PVP,+,5,mM N2H4, pH,3.85 for all the matrices except seawater. For ITP of seawater the LE consisted of 50,mM HCl,+,100,mM ,-Ala,+,10% PVP +,2.86,mM N2H4×2HCl, pH,3.52. Distance of conductivity detector from the injection point and bifurcation point was 52 and 38,mm, respectively. Zone electrophoresis was performed in a capillary made of fused silica of 0.3,mm id and 160,mm total length filled with LE from isotachophoretic step. LODs reached for all matrices were 2,3×10,8,M concentration (2.5,4,,g/L) enabled monitoring of iodide in all analyzed samples with RSD 0.4,9.3%. Estimated concentrations of iodide in individual matrices were 10,6,10,8,M. [source]


Investigation of metabolite changes in the transition from pre-invasive to invasive cervical cancer measured using 1H and 31P magic angle spinning MRS of intact tissue

NMR IN BIOMEDICINE, Issue 2 2009
Sonali S. De Silva
Abstract The aim of this study was to determine the metabolic changes in the transition from pre-invasive to invasive cervical cancer using high-resolution magic angle spinning (HR-MAS) MRS. Biopsy specimens were obtained from women with histologically normal cervix (n,=,5), cervical intraepithelial neoplasia (CIN; mild, n,=,5; moderate/severe, n,=,40), and invasive cancer (n,=,23). 1H HR-MAS MRS data were acquired using a Bruker Avance 11.74,T spectrometer (Carr,Purcell,Meiboom,Gill sequence; TR,=,4.8,s; TE,=,135,ms; 512 scans; 41,min acquisition). 31P HR-MAS spectra were obtained from the normal subjects and cancer patients only (as acetic acid applied before tissue sampling in patients with CIN impaired spectral quality) using a 1H-decoupled pulse-acquire sequence (TR,=,2.82,s; 2048 scans; 96,min acquisition). Peak assignments were based on values reported in the literature. Peak areas were measured using the AMARES algorithm. Estimated metabolite concentrations were compared between patient diagnostic categories and tissue histology using independent samples t tests. Comparisons based on patient category at diagnosis showed significantly higher estimated concentrations of choline (P,=,0.0001) and phosphocholine (P,=,0.002) in tissue from patients with cancer than from patients with high-grade dyskaryosis, but no differences between non-cancer groups. Division by histology of the sample also showed increases in choline (P,=,0.002) and phosphocholine (P,=,0.002) in cancer compared with high-grade CIN tissue. Phosphoethanolamine was increased in cancer compared with normal tissue (P,=,0.0001). Estimated concentrations of alanine (P,=,0.01) and creatine (P,=,0.008) were significantly reduced in normal tissue from cancer patients compared with normal tissue from non-cancer patients. The estimated concentration of choline was significantly increased in CIN tissue from cancer patients compared with CIN tissue from non-cancer patients (P,=,0.0001). Estimated concentrations of choline-containing metabolites increased from pre-invasive to invasive cervical cancer. Concurrent metabolite depletion occurs in normal tissue adjacent to cancer tissue. Copyright © 2008 John Wiley & Sons, Ltd. [source]


The local lymph node assay and the assessment of relative potency: status of validation

CONTACT DERMATITIS, Issue 2 2007
David A. Basketter
For the prediction of skin sensitization potential, the local lymph node assay (LLNA) is a fully validated alternative to guinea-pig tests. More recently, information from LLNA dose,response analyses has been used to assess the relative potency of skin sensitizing chemicals. These data are then deployed for risk assessment and risk management. In this commentary, the utility and validity of these relative potency measurements are reviewed. It is concluded that the LLNA does provide a valuable assessment of relative sensitizing potency in the form of the estimated concentration of a chemical required to produce a threefold stimulation of draining lymph node cell proliferation compared with concurrent controls (EC3 value) and that all reasonable validation requirements have been addressed successfully. EC3 measurements are reproducible in both intra- and interlaboratory evaluations and are stable over time. It has been shown also, by several independent groups, that EC3 values correlate closely with data on relative human skin sensitization potency. Consequently, the recommendation made here is that LLNA EC3 measurements should now be regarded as a validated method for the determination of the relative potency of skin sensitizing chemicals, a conclusion that has already been reached by a number of independent expert groups. [source]


Wastewater treatment polymers identified as the toxic component of a diamond mine effluent

ENVIRONMENTAL TOXICOLOGY & CHEMISTRY, Issue 9 2004
Simone J. C. de Rosemond
Abstract The EkatiÔ Diamond Mine, located approximately 300 km northeast of Yellowknife in Canada's Northwest Territories, uses mechanical crushing and washing processes to extract diamonds from kimberlite ore. The processing plant's effluent contains kimberlite ore particles (,0.5 mm), wastewater, and two wastewater treatment polymers, a cationic polydiallydimethylammonium chloride (DADMAC) polymer and an anionic sodium acrylate polyacrylamide (PAM) polymer. A series of acute (48-h) and chronic (7-d) toxicity tests determined the processed kimberlite effluent (PKE) was chronically, but not acutely, toxic to Ceriodaphnia dubia. Reproduction of C. dubia was inhibited significantly at concentrations as low as 12.5% PKE. Toxicity identification evaluations (TIE) were initiated to identify the toxic component of PKE. Ethylenediaminetetraacetic acid (EDTA), sodium thiosulfate, aeration, and solid phase extraction with C-18 manipulations failed to reduce PKE toxicity. Toxicity was reduced significantly by pH adjustments to pH 3 or 11 followed by filtration. Toxicity testing with C. dubia determined that the cationic DADMAC polymer had a 48-h median lethal concentration (LC50) of 0.32 mg/L and 7-d median effective concentration (EC50) of 0.014 mg/L. The anionic PAM polymer had a 48-h LC50 of 218 mg/L. A weight-of-evidence approach, using the data obtained from the TIE, the polymer toxicity experiments, the estimated concentration of the cationic polymer in the kimberlite effluent, and the behavior of kimberlite minerals in pH-adjusted solutions provided sufficient evidence to identify the cationic DADMAC polymer as the toxic component of the diamond mine PKE. [source]


Methadone dose and post-mortem blood concentration

DRUG AND ALCOHOL REVIEW, Issue 4 2002
Dr. JOHN R. M. CAPLEHORN
Abstract The relationship of methadone dose with post-mortem blood concentration was investigated using data collected from 1994 coronial cases in the Australian state of New South Wales. Data on 31 subjects were summarized using linear regression. The weight-adjusted methadone dose, gender, methadone maintenance treatment status and its interaction with adjusted-dose were all significant predictors of post-mortem blood methadone concentration. Data on the death of a young man from the toxic effects of three daily doses of 30mg methadone are used to give an example of a pair of observed (0.74 mg/l) and predicted (0.48 mg/l) post-mortem blood concentrations. The estimated post-mortem blood concentration for male maintenance patients is at least twice the trough plasma levels estimated from previously published studies of living maintenance patients. The estimated post-mortem blood concentration for female maintenance patients is at least three times the estimated trough level of living subjects. We conclude that post-mortem methadone redistribution is probably the principal cause of the observed differences between males and females in post-mortem blood concentrations and the differences between estimated concentrations for living and deceased subjects. [source]


Determination of 17,-estradiol in bovine plasma: development of a highly sensitive technique by ion trap gas chromatography,tandem mass spectrometry using negative chemical ionization,

JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 12 2002
Giancarlo Biancotto
Abstract A novel approach to the determination of 17,-estradiol in bovine plasma is presented. The observed enhanced sensitivity is gained by the application of tandem mass spectrometry (MS) fragmentation to a stable, well characterized negative ion produced by chemical ionization (methane as reagent gas). A specific derivatizing reactant is employed (pentafluorobenzyl bromide), combined with bis-trimethylsilyltrifluoroacetamide, to favor the formation of a diagnostic precursor negative ion. Plasma samples are purified through a C18 solid phase extraction column and derivatized before gas chromatography,MS analysis. The accuracy and the precision of the method, tested over a set of spiked samples, were satisfactory. The limit of detection was found to be 5 pg ml,1 and the limit of quantification was fixed at 20 pg ml,1. The fragmentation pattern is fully explained and the method is applicable for the official analysis of bovine plasma for the detection of 17,-estradiol according to the European criteria 256/93 and to the draft SANCO/1805/2000 rev. 3. The quantification of incurred positive samples was performed according to the proposed procedure and compared with the results obtained by standardized radio immuno assay; the estimated concentrations were significantly similar. Copyright © 2002 John Wiley & Sons, Ltd. [source]