1H spectroscopic imaging of human brain at 3 Tesla: Comparison of fast three-dimensional magnetic resonance spectroscopic imaging techniques

JOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 3 2009
Matthew L. Zierhut PhD
Abstract Purpose To investigate the signal-to-noise-ratio (SNR) and data quality of time-reduced three-dimensional (3D) proton magnetic resonance spectroscopic imaging (1H MRSI) techniques in the human brain at 3 Tesla. Materials and Methods Techniques that were investigated included ellipsoidal k -space sampling, parallel imaging, and echo-planar spectroscopic imaging (EPSI). The SNR values for N-acetyl aspartate, choline, creatine, and lactate or lipid peaks were compared after correcting for effective spatial resolution and acquisition time in a phantom and in the brains of human volunteers. Other factors considered were linewidths, metabolite ratios, partial volume effects, and subcutaneous lipid contamination. Results In volunteers, the median normalized SNR for parallel imaging data decreased by 34,42%, but could be significantly improved using regularization. The normalized signal to noise loss in flyback EPSI data was 11,18%. The effective spatial resolutions of the traditional, ellipsoidal, sensitivity encoding (SENSE) sampling scheme, and EPSI data were 1.02, 2.43, 1.03, and 1.01 cm3, respectively. As expected, lipid contamination was variable between subjects but was highest for the SENSE data. Patient data obtained using the flyback EPSI method were of excellent quality. Conclusion Data from all 1H 3D-MRSI techniques were qualitatively acceptable, based upon SNR, linewidths, and metabolite ratios. The larger field of view obtained with the EPSI methods showed negligible lipid aliasing with acceptable SNR values in less than 9.5 min without compromising the point-spread function. J. Magn. Reson. Imaging 2009;30:473,480. © 2009 Wiley-Liss, Inc. [source]


Spectral phase-corrected GRAPPA reconstruction of three-dimensional echo-planar spectroscopic imaging (3D-EPSI)

MAGNETIC RESONANCE IN MEDICINE, Issue 5 2007
Xiaoping Zhu
Abstract MR spectroscopic (MRS) images from a large volume of brain can be obtained using a 3D echo-planar spectroscopic imaging (3D-EPSI) sequence. However, routine applications of 3D-EPSI are still limited by a long scan time. In this communication, a new approach termed "spectral phase-corrected generalized autocalibrating partially parallel acquisitions" (SPC-GRAPPA) is introduced for the reconstruction of 3D-EPSI data to accelerate data acquisition while preserving the accuracy of quantitation of brain metabolites. In SPC-GRAPPA, voxel-by-voxel spectral phase alignment between metabolite 3D-EPSI from individual coil elements is performed in the frequency domain, utilizing the whole spectrum from interleaved water reference 3D-EPSI for robust estimation of the zero-order phase correction. The performance of SPC-GRAPPA was compared with that of fully encoded 3D-EPSI and conventional GRAPPA. Analysis of whole-brain 3D-EPSI data reconstructed by SPC-GRAPPA demonstrates that SPC-GRAPPA with an acceleration factor of 1.5 yields results very similar to those obtained by fully encoded 3D-EPSI, and is more accurate than conventional GRAPPA. Magn Reson Med 57:815,820, 2007. © 2007 Wiley-Liss, Inc. [source]


Anatomical and functional brain imaging using high-resolution echo-planar spectroscopic imaging at 1.5 Tesla

NMR IN BIOMEDICINE, Issue 4 2005
Weiliang Du
Abstract High-resolution echo-planar spectroscopic imaging (EPSI) of water resonance (i.e. without water suppression) is proposed for anatomic and functional imaging of the human brain at 1.5,T. Water spectra with a resolution of 2.6,Hz and a bandwidth of 333,Hz were obtained in small voxels (1.7,×,1.7,×,3,mm3) across a single slice. Although water spectra appeared Lorentzian in most of the voxels in the brain, non-Lorentzian broadening of the water resonance was observed in voxels containing blood vessels. In functional experiments with a motor task, robust activation in motor cortices was observed in high-resolution T maps generated from the EPSI data. Shift of the water resonance frequency occurred during neuronal activation in motor cortices. The activation areas appeared to be more localized after excluding the voxels in which the lineshape of the water resonance had elevated T and became more non-Lorentzian during the motor task. These preliminary results suggest that high-resolution EPSI is a promising tool to study susceptibility-related effects, such as BOLD contrast, for improved anatomical and functional imaging of the brain. Copyright © 2005 John Wiley & Sons, Ltd. [source]