AF Burden (af + burden)

Distribution by Scientific Domains


Selected Abstracts


Characterization of the Electroanatomical Substrate in Human Atrial Fibrillation: The Relationship between Changes in Atrial Volume, Refractoriness, Wavefront Propagation Velocities, and AF Burden

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 3 2007
PIPIN KOJODJOJO M.R.C.P.
Introduction: Progressive remodeling occurs in experimental models of AF whereby slowing of conduction, shortening of refractoriness, and atrial dilatation are associated with an increased vulnerability to atrial fibrillation (AF). This study investigates the relative changes in atrial geometry and electrophysiology with increasing AF burden in humans. Methods and Results: Patients undergoing ablation of AF or left-sided accessory pathways were recruited. Atrial volumes were determined by echocardiography. Wavefront propagation velocities (WPV), specifically in the direction of activation, were calculated from pre-ablation activation (CartoÔ) maps of both atria. Dispersion, adaptation of, and effective refractoriness (ERP) were measured at 3 sites. A composite arrhythmogenic index (Atrial Volume/WPV × ERP) was derived to compare the degree of electroanatomical remodeling with AF burden. Fifty-nine patients (22 paroxysmal AF, 19 recurrent persistent AF, and 18 controls) were recruited. AF subjects had slower right atrial WPV (P = 0.01), but no difference in left atrial WPV compared with controls. ERP was reduced globally (P < 0.05), with increased dispersion (P < 0.05). WPV and ERP did not distinguish between patients with paroxysmal or persistent AF. Biatrial volumes were greater only in patients with persistent AF (P < 0.01). There was a stepwise increase in the AI with increasing AF burden (P < 0.0001). Conclusion: An arrhythmogenic substrate exists in human AF, characterized by globally decreased refractoriness with greater dispersion, slower right atrial conduction, and atrial dilatation. Persistence of AF is not accompanied by any further electrical remodeling, but only atrial dilatation. The degree of electroanatomical remodeling is associated with the clinical pattern of AF. [source]


Comparison of Cool Tip Versus 8-mm Tip Catheter in Achieving Electrical Isolation of Pulmonary Veins for Long-Term Control of Atrial Fibrillation: A Prospective Randomized Pilot Study

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2006
SANJAY DIXIT M.D.
Objective: To compare safety and efficacy of 8-mm versus cooled tip catheter in achieving electrical isolation (EI) of pulmonary veins (PV) for long-term control of atrial fibrillation (AF). Background: There is paucity of studies comparing safety/efficacy of 8-mm and cooled tip catheters in patients undergoing AF ablation. Methods and Results: This was a randomized and patient-blinded study. Subjects were followed by clinic visits (at 6 weeks and 6 months) and transtelephonic monitoring (3-week duration) done around each visit. Primary endpoints were: (1) long-term AF control (complete freedom and/or >90% reduction in AF burden on or off antiarrhythmic drugs at 6 months after a single ablation), and (2) occurrence of serious adverse events (cardiac tamponade, stroke, LA-esophageal fistula, and/or death). Eighty-two patients (age 56 ± 9 years, 60 males, paroxysmal AF = 59) were randomized (42 patients to 8-mm tip and 40 patients to cooled tip). EI of PVs was achieved in shorter time by the 8-mm tip as compared with cooled tip catheter (40 ± 23 minutes vs 50 ± 30 minutes; P < 0.05) but long-term AF control was not different between the two (32 patients [78%] vs 28 patients [70%], respectively; P = NS). One serious adverse event occurred in each group (LA-esophageal fistula and stroke, respectively) and no significant PV stenosis was observed in either. Conclusion: EI of PVs using either 8-mm or cooled tip catheter results in long-term AF control in the majority after a single ablation procedure, with comparable efficacy and safety. [source]


Atrial Fibrillation Burden During the Post-Implant Period After CRT Using Device-Based Diagnostics

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 8 2006
BURKHARD HÜGL M.D.
Aims: Cardiac resynchronization therapy (CRT) is increasingly used in congestive heart failure (CHF) patients (with cardiac dyssynchrony). In addition to delivering therapy, CRT devices offer a variety of diagnostic tools for continuous long-term monitoring of clinically relevant information (i.e., occurrence and duration of arrhythmia episodes). Methods and Results: Eighty-four patients with drug-refractory CHF in NYHA-class II,IV received a CRT device. The response to CRT was assessed by determining NYHA class at baseline and at 3 months follow-up. Atrial fibrillation (AF) burden (defined as time of AF per day) was continuously measured by the device. A significant gradual reduction of AF burden (from 9.88 ± 12.61 to 4.20 ± 9.24 [hours/day]) and number of patients experiencing AF episodes (from 26 to 13) were observed during CRT. Conclusions: (1) Diagnostic features for long-term monitoring of physiological variables provide useful information on the state and course of AF and may improve disease management. (2) AF burden reduces over time during the first 3 months after CRT implantation. [source]


Total Atrioventricular Nodal Ablation Increases Atrial Fibrillation Burden in Patients with Paroxysmal Atrial Fibrillation Despite Continuation of Antiarrhythmic Drug Therapy

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 12 2003
RIK WILLEMS M.D.
Introduction: Total atrioventricular nodal (TAVN) ablation and pacing is an accepted and safe treatment for patients with drug-refractory paroxysmal atrial fibrillation (AF). Many patients develop permanent AF within the first 6 months after TAVN ablation. This usually is ascribed to the cessation of antiarrhythmic drug therapy. We hypothesized that TAVN ablation itself creates an atrial substrate prone to AF. Methods and Results: Patients participating in the Atrial Pacing Periablation for Paroxysmal Atrial Fibrillation (PA3) study who remained on stable antiarrhythmic drug therapy throughout follow-up were included in this analysis. AF burden and the development of persistent AF in the preablation period were compared to two consecutive postablation periods. Echocardiographic changes also were evaluated. Twenty-two patients remained on stable drug therapy (9 men and 13 women, age 59 ± 3 years). One patient developed persistent AF preablation compared to 10 postablation (P < 0.05). AF burden preablation was 3.0 ± 1.2 hours/day and increased to 10.4 ± 2.2 hours/day and 11.8 ± 2.3 hours/day in the two postablation follow-up periods (P < 0.05). In patients with fractional shortening (FS) >30% prior to ablation, FS decreased significantly from 39.4%± 1.3% to 36.4%± 1.7% (P < 0.05). In contrast, in patients with a FS ,30% prior to ablation, FS increased from 27%± 0.8% to 33.6 ± 1.7% (P < 0.05). Conclusion: TAVN ablation increases AF burden and facilitates the development of persistent AF in patients with paroxysmal AF despite the continuation of antiarrhythmic drugs. Loss of AV and/or interventricular synchrony may lead to altered cardiac hemodynamics resulting in atrial stretch and increasing AF burden. (J Cardiovasc Electrophysiol, Vol. 14, pp. 1296-1301, December 2003) [source]


Effects of Continuous and Triggered Atrial Overdrive Pacing on Paroxysmal Atrial Fibrillation in Pacemaker Patients

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 8 2008
ANDREAS SCHUCHERT M.D.
Background: The aim of the study was to compare the effects of different pacing strategies to prevent paroxysmal atrial fibrillation (AF): triggered atrial overdrive pacing versus the combination of triggered and continuous overdrive pacing. Methods: Patients with an indication for dual-chamber pacing (Selection 9000, Prevent AF; Vitatron B.V., Arnhem, the Netherlands) and a history of paroxysmal AF were randomized to triggered atrial pacing (three pacing functions, "triggered group": PAC SuppressionÔ, Post-PAC ResponseÔ, and Post-Exercise ResponseÔ) or to the combination of continuous (Pace ConditioningÔ) and triggered atrial pacing (four pacing functions, "combined group"). After 3 months, there was a crossover to the other pacemaker setting. Results: In 171 enrolled patients, the median AF burden of the combined group was with 2.1% versus 0.1% in the triggered group (P = 0.014). Fewer AF episodes were observed in the triggered (median: 7) than in the combined group (median: 116; P = 0.016). The combined group had more frequent atrial pacing (median 97%) than the triggered group with 85% (P < 0.001), but ventricular pacing was not significantly different with 95% and 96% in the combined and triggered group, respectively. After the crossover, the AF burden increased in the triggered group to 0.3% and decreased in the combined group to 0.4%. Conclusions: Triggered atrial pacing functions alone resulted in a low AF burden. The additional activation of continuous atrial overdrive pacing increased the percentage of atrial pacing, but had no beneficial effects on the prevention of paroxysmal AF. [source]


Individualized Selection of Pacing Algorithms for the Prevention of Recurrent Atrial Fibrillation: Results from the VIP Registry

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 2 2006
THORSTEN LEWALTER
Objectives: The VIP registry investigated the efficacy of preventive pacing algorithm selection in reducing atrial fibrillation (AF) burden. Background: There are few data identifying which patients might benefit most from which preventive pacing algorithms. Methods: Patients, with at least one documented AF episode and a conventional antibradycardia indication for pacemaker therapy, were enrolled. They received pacemakers with AF diagnostics and four preventive algorithms (Selection and PreventAF series, Vitatron). A 3-month Diagnostic Phase with conventional pacing identified a Substrate Group (>70% of AF episodes with <2 premature atrial contractions [PACs] before AF onset) and a Trigger Group (,70% of AF episodes with <2 PACs before AF onset). This was followed by a 3-month Therapeutic Phase where in the Trigger Group algorithms were enabled aimed at avoiding or preventing a PAC and in the Substrate Group continuous atrial overdrive pacing was enabled. Results: One hundred and twenty-six patients were evaluated. In the Trigger Group (n = 73), there was a statistically significant 28% improvement in AF burden (median AF burden: 2.06 hours/day, Diagnostic Phase vs 1.49 hours/day, Therapy Phase; P = 0.03304 signed-rank test), and reduced PAC activity. There was no significant improvement in AF burden in the Substrate Group (median AF burden: 1.82 hours/day, Diagnostic Phase vs 2.38 hours/day, Therapy Phase; P = 0.12095 signed-rank test), and little change in PAC activity. Conclusions: We identified a subgroup of patients for whom the selection of appropriate pacing algorithms, based on individual diagnostic data, translated into a reduced AF burden. Trigger AF patients were more likely responders to preventive pacing algorithms as a result of PAC suppression. [source]