Home About us Contact | |||
Early Pregnancy Diagnosis (early + pregnancy_diagnosis)
Selected AbstractsEarly Pregnancy Diagnosis by Serum Progesterone and Ultrasound in Sheep Carrying Somatic Cell Nuclear Transfer-Derived PregnanciesREPRODUCTION IN DOMESTIC ANIMALS, Issue 2 2008B Alexander Contents Early pregnancy diagnosis and monitoring play an important role following embryo transfer in sheep. The aims of the current study were to investigate (i) the pattern of serum progesterone profiles in sheep carrying somatic cell nuclear transfer (SCNT)-derived (clone) pregnancies, and (ii) the frequency of pregnancy loss during development following SCNT embryo transfer. Sheep SCNT embryos were made using standard nuclear transfer techniques. Day 7 embryos were surgically transferred to oestrus-synchronized recipients (n = 27). As a control, normal fertile ewes (n = 12) were bred by natural breeding. Serum was collected from all the ewes on the day of estrus (day 0 sample), 7 days post-estrus (day 7 sample) and 19 days post-estrus (day 19 sample) and every 10 days thereafter until lambing or pregnancy loss occurred. Serum progesterone (P4) was assessed using enzyme immunoassay. Pregnancy was confirmed by ultrasound scanning on day 35 of pregnancy followed by subsequent scanning every 10 days. In control ewes, pregnancy rate on day 35 was 83.3% (10/12), whereas in the ewes that received SCNT embryos, it was 22.2% (6/27; p < 0.05). The day 45 pregnancy rate in the control ewes was 83.3%, whereas in the SCNT embryo recipients it was 11.0% (p < 0.05). Hormone analysis revealed that SCNT embryo recipients exhibited a significantly lower P4 profiles at different time points in pregnancy compared to controls (p < 0.05). This study highlights the use of serum progesterone in combination with ultrasound for the investigation of embryo loss and crucial times during development of normal and SCNT embryos in sheep. Further, the serum P4 levels directly reflect the degree of placental development in these two groups. [source] Assessment of Progesterone Concentration Using Enzymeimmunoassay, for Early Pregnancy Diagnosis in Sheep and GoatsREPRODUCTION IN DOMESTIC ANIMALS, Issue 3 2003CM Boscos Contents The objective of this study was to determine a value of serum progesterone (P4) concentration, assessed using an enzymeimmunoassay (EIA), for the early distinction between pregnant and non-pregnant ewes and goats. Adult, non-lactating ewes of Chios (n=53), Berrichon (n=30) and Sfakia (n=45) breeds were synchronized during the breeding season with progestagens and gonadotrophins and mated to fertile rams (Experiment I). Adult, lactating goats of Swiss breeds (Alpine and Saanen, n=104) and indigenous Greek breed (n=45) were synchronized during the transitional season with progestagens, PGF2, and gonadotrophins. Cervical artificial insemination (AI) with fresh semen was applied once, 42,44 h after sponge removal (Experiment II). Jugular blood samples were collected on day 19 after sponge removal (ewes) or on day 21 after AI (goats) and serum P4 concentration was determined by EIA. Progesterone concentrations ,1.0, ,1.5, ,2.5 and ,4.0 ng/ml were tested as indicative of pregnancy. Pregnancy diagnosis was verified on birth. In the case of sheep, using a discriminatory level of 2.5 ng/ml, overall accuracy of pregnancy diagnosis was 91.4% and predictive value of negative and positive diagnoses were 98.3 and 85.3%, respectively. In the case of goats, predictive value of negative diagnosis was 95.8 and 94.0% and predictive value of positive diagnosis 71.3 and 71.7%, for 1.5 and 2.5 ng/ml, respectively; overall accuracy was 79.2% using either level. The other discriminatory levels tested did not improve these results. A significant positive correlation was observed between P4 concentration and the number of lambs or kids born, and further analysis indicated that this relationship is not a simple linear function. Based on the results of this study, P4 concentrations of 2.5 ng/ml in the case of ewes and 1.5,2.5 ng/ml in the case of goats, determined with EIA, are proposed as discriminatory levels between pregnant and non-pregnant animals, at an interval of one oestrous cycle after service. [source] Early Pregnancy Diagnosis by Serum Progesterone and Ultrasound in Sheep Carrying Somatic Cell Nuclear Transfer-Derived PregnanciesREPRODUCTION IN DOMESTIC ANIMALS, Issue 2 2008B Alexander Contents Early pregnancy diagnosis and monitoring play an important role following embryo transfer in sheep. The aims of the current study were to investigate (i) the pattern of serum progesterone profiles in sheep carrying somatic cell nuclear transfer (SCNT)-derived (clone) pregnancies, and (ii) the frequency of pregnancy loss during development following SCNT embryo transfer. Sheep SCNT embryos were made using standard nuclear transfer techniques. Day 7 embryos were surgically transferred to oestrus-synchronized recipients (n = 27). As a control, normal fertile ewes (n = 12) were bred by natural breeding. Serum was collected from all the ewes on the day of estrus (day 0 sample), 7 days post-estrus (day 7 sample) and 19 days post-estrus (day 19 sample) and every 10 days thereafter until lambing or pregnancy loss occurred. Serum progesterone (P4) was assessed using enzyme immunoassay. Pregnancy was confirmed by ultrasound scanning on day 35 of pregnancy followed by subsequent scanning every 10 days. In control ewes, pregnancy rate on day 35 was 83.3% (10/12), whereas in the ewes that received SCNT embryos, it was 22.2% (6/27; p < 0.05). The day 45 pregnancy rate in the control ewes was 83.3%, whereas in the SCNT embryo recipients it was 11.0% (p < 0.05). Hormone analysis revealed that SCNT embryo recipients exhibited a significantly lower P4 profiles at different time points in pregnancy compared to controls (p < 0.05). This study highlights the use of serum progesterone in combination with ultrasound for the investigation of embryo loss and crucial times during development of normal and SCNT embryos in sheep. Further, the serum P4 levels directly reflect the degree of placental development in these two groups. [source] Comparison of transcutaneous ultrasound over the right flank with transrectal ultrasound for pregnancy diagnosis in the dairy cowAUSTRALIAN VETERINARY JOURNAL, Issue 8 2009JC Hunnam Objective Evaluate the sensitivity and specificity of transrectal ultrasound and transcutaneous ultrasonography across the right flank between days 31 and 196 of pregnancy in the dairy cow. Procedure Pregnancy status and stage of gestation at date of pregnancy diagnosis by transcutaneous and transrectal ultrasonography were determined for 1570 dairy cattle. Sensitivity and specificity values and probabilities of a correct diagnosis for both techniques were determined and compared. Possible effects of gestational age, herd, method of transcutaneous ultrasound diagnosis, cow age, cow and bull breed, and calf sex on the determination of a correct diagnosis of pregnancy status were evaluated for both techniques. Results The overall sensitivity and probability of a correct diagnosis of pregnancy status from days 31 to 196 of gestation were significantly higher when using transrectal ultrasound relative to transcutaneous ultrasound over the right flank. However, the sensitivity of transcutaneous ultrasound changed over the course of pregnancy: it was low (7,8%) before day 84, increased to 89% between days 141 and 154, and was close to 100% thereafter. The specificity of both methods did not differ significantly. Herd and gestational age at date of pregnancy diagnosis were significantly associated with making a correct test result using transcutaneous ultrasound, although only the latter predictor was significantly associated with making a correct test result using transrectal ultrasound. Conclusion Transcutaneous ultrasound can not be recommended as an accurate method for early pregnancy diagnosis in the dairy cow, particularly on a whole-herd basis. However, if pregnancy testing is undertaken in mid to late gestation, this technique could provide an accurate and rapid alternative to transrectal ultrasound or manual palpation per rectum. [source] |