Home About us Contact | |||
Diabetic Dogs (diabetic + dog)
Selected AbstractsReduced tear production in three canine endocrinopathies,JOURNAL OF SMALL ANIMAL PRACTICE, Issue 5 2007D. L. Williams Objectives: Previous reports have suggested that hypothyroid and diabetic patients can be predisposed to keratoconjunctivitis sicca. This study aimed to measure tear production in dogs with diabetes, hypothyroidism and hyperadrenocorticism using the Schirmer tear test and to compare these results with Schirmer tear test values for a group of normal dogs. Methods: Schirmer tear tests were performed on 16 dogs with hyperadrenocorticism, 18 with diabetes and 12 with hypothyroidism together with 100 control dogs. Corneal sensitivity was also measured in 12 of the 18 diabetic dogs with a Cochet Bonnet aesthesiometer and compared with age- and breed-matched normal dogs. Results: Schirmer tear test values in dogs with hypothyroidism, hyperadrenocorticism and diabetes were 12·3±3·2, 14·0±4·0 and 12·3±5·3 mm/minutes, respectively. Schirmer tear test values were significantly lower than that for the control group (19·6±4·2 mm/minutes) in all dogs with an endocrinopathy. Only in two hypothyroid dogs and three diabetics, this was manifested as profound keratoconjunctivitis sicca with Schirmer tear test value lower than 5 mm/minutes. Diabetic dogs had significantly reduced corneal sensitivity compared with a matched set of control dogs. Clinical Significance: This study shows a significant reduction in tear production in animals with diabetes mellitus, hypothyroidism and hyperadrenocorticism. Further research is needed to elucidate the mechanisms by which this reduction in tear production occurs. Assessment of tear production should be undertaken in animals diagnosed with these endocrinopathies, as these animals may progress to clinical keratoconjunctivitis sicca. [source] Exocrine pancreatic insufficiency as an end stage of pancreatitis in four dogsJOURNAL OF SMALL ANIMAL PRACTICE, Issue 7 2003P. J. Watson Chronic pancreatitis is a common cause of exocrine pancreatic insufficiency (EPI) in humans and cats but is rarely recognised in dogs in which pancreatic acinar atrophy (PAA) is reportedly more common. This paper describes four dogs which developed EPI secondary to pancreatitis. Two of the dogs also had diabetes mellitus which developed before EPI. One diabetic dog had concurrent hyperadrenocorticism and was euthanased five months after presentation; the other diabetic dog died 48 months after diagnosis. The remaining dogs were alive 78 and 57 months after diagnosis. The number of affected dogs was comparable to the number of cases of presumed PAA seen over the same time period in the same institution. Chronic pancreatitis may be a more common cause of EPI in dogs than previously assumed and may be under-recognised because of difficulties in diagnosis. The relative importance of chronic pancreatitis as a cause of canine diabetes mellitus remains to be ascertained. [source] The relationship between peripheral glucose utilisation and insulin sensitivity in the regulation of hepatic glucose production: studies in normal and alloxan-diabetic dogsDIABETES/METABOLISM: RESEARCH AND REVIEWS, Issue 2 2006M. J. Christopher Abstract Background Hepatic glucose overproduction (HGP) of diabetes could be primary or could occur in response to the metabolic needs of peripheral (skeletal muscle (SkM)) tissues. This question was tested in normal and diabetic dogs. Methods HGP, SkM glucose uptake (Rdtissue), metabolic clearance of glucose (MCRg) and glycolytic flux (GFexog), and SkM biopsies were measured in the same dogs before and after alloxan-induced diabetes. Normal dogs were exposed to (1) an extended 20-h fast, (2) low- and high-dose glucose infusions (GINF) at basal insulinaemia, and chronic diabetic dogs were exposed to (3) hyperglycaemia, (4) phlorizin-induced normoglycaemia, and (5) poor and good diabetic control. Results (1) Prolonged fast: HGP, Rdtissue, and GFexog fell in parallel (p < 0.05). (2) Low-dose GINF: plasma glucose, insulin, Rdtissue, MCRg, and GFexog were unchanged, but HGP fell by ,40%, paralleling the supplemental GINF. (3) High-dose GINF at basal insulin: plasma glucose doubled and synchronous changes in HGP, Rdtissue, MCRg, and GFexog occurred; ICglucose, G6P, and glycogen were unchanged. (4) Hyperglycaemic diabetes: HGP was raised (p < 0.05), matching urinary glucose loss (UGL) and decreased MCRg, and maintaining normal basal Rdtissue and GFexog. SkM ICglucose was increased and glycogen decreased (both p < 0.05). (5) Phlorizin-induced normoglycaemia in diabetic dogs: HGP rose, matching the increased UGL, while maintaining normal Rdtissue and GFexog. Intramuscular substrates normalised. (6) Whole body and SkM metabolism normalised with correction of the insulin resistance and good diabetic control. Conclusion HGP reflects whether SkM is in a state of relative glucose ,excess' or absolute/relative glucose ,deprivation'. Copyright © 2005 John Wiley & Sons, Ltd. [source] Canine diabetes mellitus: from phenotype to genotypeJOURNAL OF SMALL ANIMAL PRACTICE, Issue 1 2008B. Catchpole Breed differences in susceptibility to diabetes mellitus in dogs suggest an underlying genetic component to the pathogenesis of the disease. There is little evidence for an equivalent of human type 2 diabetes in dogs, and it has been proposed that canine diabetes is more comparable to the type 1 form of the disease. Certain immune response genes, particularly those encoding major histocompatibility complex molecules involved in antigen presentation, are important in determining susceptibility to human type 1 diabetes. We tested the hypothesis that canine major histocompatibility complex genes (known as the dog leucocyte antigen) are associated with diabetes in dogs. A total of 530 diabetic dogs and more than 1000 controls were typed for dog leucocyte antigen, and associations were found with three specific haplotypes. The DLA-DRB1*009/DQA1*001/DQB1*008 haplotype shows the strongest association with diabetes in the UK dog population. This haplotype is common in diabetes-prone breeds (Samoyed, cairn terrier and Tibetan terrier) but rare in diabetes-resistant breeds (boxer, German shepherd dog and golden retriever), which could explain differences in the prevalence of diabetes in these different breeds. There is evidence that the DLA-DQA1*001 allele is also associated with hypothyroidism, suggesting that this could represent a common susceptibility allele for canine immune-mediated endocrinopathies. [source] Reduced tear production in three canine endocrinopathies,JOURNAL OF SMALL ANIMAL PRACTICE, Issue 5 2007D. L. Williams Objectives: Previous reports have suggested that hypothyroid and diabetic patients can be predisposed to keratoconjunctivitis sicca. This study aimed to measure tear production in dogs with diabetes, hypothyroidism and hyperadrenocorticism using the Schirmer tear test and to compare these results with Schirmer tear test values for a group of normal dogs. Methods: Schirmer tear tests were performed on 16 dogs with hyperadrenocorticism, 18 with diabetes and 12 with hypothyroidism together with 100 control dogs. Corneal sensitivity was also measured in 12 of the 18 diabetic dogs with a Cochet Bonnet aesthesiometer and compared with age- and breed-matched normal dogs. Results: Schirmer tear test values in dogs with hypothyroidism, hyperadrenocorticism and diabetes were 12·3±3·2, 14·0±4·0 and 12·3±5·3 mm/minutes, respectively. Schirmer tear test values were significantly lower than that for the control group (19·6±4·2 mm/minutes) in all dogs with an endocrinopathy. Only in two hypothyroid dogs and three diabetics, this was manifested as profound keratoconjunctivitis sicca with Schirmer tear test value lower than 5 mm/minutes. Diabetic dogs had significantly reduced corneal sensitivity compared with a matched set of control dogs. Clinical Significance: This study shows a significant reduction in tear production in animals with diabetes mellitus, hypothyroidism and hyperadrenocorticism. Further research is needed to elucidate the mechanisms by which this reduction in tear production occurs. Assessment of tear production should be undertaken in animals diagnosed with these endocrinopathies, as these animals may progress to clinical keratoconjunctivitis sicca. [source] Evaluation of a continuous glucose monitoring system in diabetic dogsJOURNAL OF SMALL ANIMAL PRACTICE, Issue 10 2003L. J. Davison The generation of a blood glucose curve is important for assessing the response to insulin therapy in diabetic dogs. Disadvantages of this technique include patient discomfort and the potential for missing transient hypo- or hyperglycaemic episodes. The aim of the current study was to evaluate a continuous glucose monitoring system (CGMS) for use in diabetic dogs. Interstitial fluid glucose concentrations were recorded in 10 diabetic dogs, every five minutes for up to 48 hours, using a subcutaneous sensor attached to the CGMS device. Blood glucose concentrations were measured simultaneously using a glucometer. The correlation between interstitial fluid and blood glucose values was 0·81 (P<0·01). The largest discrepancies between the two sets of data were seen during the one- to three-hour period following feeding, suggesting that postprandial hyperglycaemia might not be reflected in the interstitial fluid. The authors conclude that the CGMS is a potentially valuable tool in the management of canine diabetic patients. [source] Evaluating the use of plasma hematocrit samples to detect ketones utilizing urine dipstick colorimetric methodology in diabetic dogs and catsJOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, Issue 1 2003Mark A. Brady DVM Abstract Objective: To determine whether plasma from a heparinized hematocrit tube placed on a urine dipstick would accurately reflect (positive or negative) urine ketone results in diabetic dogs and cats. Design: Prospective study, 37 dogs and 43 cats, with a known history of diabetes or hyperglycemia, glucosuria, and symptoms of undiagnosed diabetes mellitus were tested. Setting: Veterinary Referral Hospital. Animals: Client owned dogs and cats. Interventions: None. Measurement and main results: Heparinized plasma and urine ketone results were recorded using urine reagent strips. Plasma dipstick results were compared to urine dipstick results as the standard. Results were recorded based on the color chart provided by the manufacturer. Two individuals were responsible for verifying the results of the colorimetric test. Test efficiency was 97% (sensitivity = 96%, specificity = 100%) for the canine population, 93% (sensitivity = 100%, specificity = 83%) for the feline population, and 95% (sensitivity = 98%, specificity = 91%) for the total population. Four of 80 animals were found to have discordant results (1 dog and 3 cats). Conclusion: Plasma from heparinized hematocrit tubes is clinically useful for detecting the presence or absence of ketonuria, and therefore ketosis, in diabetic dogs and cats using urine dipstick colorimetric methodology. [source] Continuous Glucose Monitoring in Dogs and CatsJOURNAL OF VETERINARY INTERNAL MEDICINE, Issue 1 2008C.E. Wiedmeyer Use of continuous glucose monitoring in veterinary medicine is gaining popularity. Through use of a commercially available continuous glucose monitor system, insights into daily glucose changes in dogs and cats are achievable. The continuous glucose monitoring system measures glucose concentrations in the interstitial fluid of the subcutaneous space by use of a small, flexible probe. When placed in the subcutaneous tissue, the probe is connected to a recording device that is attached to the animal and records the interstitial fluid glucose concentration every 5 minutes (288 readings per 24 hours). Once attached and properly calibrated, the instrument can remain in place for several days, hospitalization of the patient is not necessary, and the normal daily routine of the animal can be maintained. The data from the recording device are then downloaded and a very detailed picture of the interstitial fluid glucose concentration over that time period can be obtained. Subcutaneous interstitial fluid glucose concentrations have a good correlation to blood glucose concentrations within a defined range. The continuous glucose monitoring system has distinct advantages over traditional blood glucose curves and is a valuable tool for managing diabetic dogs and cats. In addition, other clinical uses for continuous glucose monitoring are being developed. This review is designed to outline the technology behind the continuous glucose monitoring system, describe the clinical use of the instrument, provide clinical examples in which it may be useful, and discuss future directions for continuous glucose monitoring in dogs and cats. [source] MITEMCINAL (GM-611), AN ORALLY ACTIVE MOTILIN RECEPTOR AGONIST, IMPROVES DELAYED GASTRIC EMPTYING IN A CANINE MODEL OF DIABETIC GASTROPARESISCLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, Issue 7 2008Mitsu Onoma SUMMARY 1The aim of the present study was to evaluate the effects of mitemcinal (GM-611), an orally active motilin receptor agonist, on delayed gastric emptying in a canine model of diabetic gastroparesis and to compare these effects with those of cisapride. 2Moderate hyperglycaemia was induced by a single intravenous injection of a mixture of streptozotocin (30 mg/kg) and alloxan (50 mg/kg). Dogs that maintained moderate hyperglycaemia (fasting plasma glucose 200,300 mg/dL) without insulin treatment were selected and gastric emptying in these dogs was determined by the paracetamol method. 3One year after the onset of diabetes, there was no difference in the gastric emptying of normal and diabetic dogs. However, after 5 years, the diabetic dogs showed delayed gastric emptying. The motor nerve conduction velocity of the tibial nerve was significantly lower in diabetic dogs comapred with normal dogs at both time points. 4Histopathological examination at the end of the study showed that there were fewer nerve fibres in both dorsal vagal and tibial nerves of diabetic dogs comapred with normal dogs. The onset of delayed gastric emptying is thought to have occurred gradually, in parallel with abnormal autonomic nerve function induced by the long period of moderate hyperglycaemia. 5Oral administration of mitemcinal (0.125, 0.25 or 0.5 mg/kg) dose-dependently accelerated delayed gastric emptying, significant at 0.5 mg/kg, in diabetic dogs, whereas cisapride (1, 3 or 10 mg/kg) had no significant effect. These results add to the existing evidence that mitemcinal is likely to be useful for treating diabetic gastroparesis. [source] |