Home About us Contact | |||
H/D Exchange Experiments (d + exchange_experiment)
Selected AbstractsDirect evidence by H/D exchange and ESI-MS for transient unproductive domain interaction in the refolding of an antibody scFv fragmentPROTEIN SCIENCE, Issue 3 2000Marcus Jäger Abstract The refolding kinetics of a single-chain Fv (scFv) fragment, derived from a stabilized mutant of the phosphorylcholine binding antibody McPC603, was investigated by H/D exchange and ESI-MS and compared with the folding kinetics of its constituting domains VH and VL. Both VH and VL adopt essentially native-like exchange protection within the dead time of the manual-mixing H/D exchange experiment (10 s) and in the case of VL, which contains two cis -prolines in the native conformation, this fast protection is independent of proline cis/trans isomerization. At the earliest time point resolvable by manual mixing, fewer deuterons are protected in the scFv fragment than in the two isolated domains together, despite the fact that the scFv fragment is significantly more stable than VL and VH. Full H/D exchange protection in the scFv fragment is gained on a time scale of minutes. This means that the domains in the scFv fragment do not refold independently. Rather, they associate prematurely and in nonnative form, a kinetic trap. Unproductive domain association is observed both after equilibrium- and short-term denaturation. For the equilibrium-denatured scFv fragment, whose native structure formation is dependent on a cis conformation of an interface proline in VL, this cis/trans isomerization reaction proceeds about one order in magnitude more slowly than the escape from the trap to a conformation where full H/D exchange protection is already achieved. We interpret these data in terms of a general kinetic scheme involving intermediates with and without domain association. [source] The Orbitrap: a new mass spectrometerJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 4 2005Qizhi Hu Abstract Research areas such as proteomics and metabolomics are driving the demand for mass spectrometers that have high performance but modest power requirements, size, and cost. This paper describes such an instrument, the Orbitrap, based on a new type of mass analyzer invented by Makarov. The Orbitrap operates by radially trapping ions about a central spindle electrode. An outer barrel-like electrode is coaxial with the inner spindlelike electrode and mass/charge values are measured from the frequency of harmonic ion oscillations, along the axis of the electric field, undergone by the orbitally trapped ions. This axial frequency is independent of the energy and spatial spread of the ions. Ion frequencies are measured non-destructively by acquisition of time-domain image current transients, with subsequent fast Fourier transforms (FFTs) being used to obtain the mass spectra. In addition to describing the Orbitrap mass analyzer, this paper also describes a complete Orbitrap-based mass spectrometer, equipped with an electrospray ionization source (ESI). Ions are transferred from the ESI source through three stages of differential pumping using RF guide quadrupoles. The third quadrupole, pressurized to less than 10,3 Torr with collision gas, acts as an ion accumulator; ion/neutral collisions slow the ions and cause them to pool in an axial potential well at the end of the quadrupole. Ion bunches are injected from this pool into the Orbitrap analyzer for mass analysis. The ion injection process is described in a simplified way, including a description of electrodynamic squeezing, field compensation for the effects of the ion injection slit, and criteria for orbital stability. Features of the Orbitrap at its present stage of development include high mass resolution (up to 150 000), large space charge capacity, high mass accuracy (2,5 ppm), a mass/charge range of at least 6000, and dynamic range greater than 10.3 Applications based on electrospray ionization are described, including characterization of transition-metal complexes, oligosaccharides, peptides, and proteins. Use is also made of the high-resolution capabilities of the Orbitrap to confirm the presence of metaclusters of serine octamers in ESI mass spectra and to perform H/D exchange experiments on these ions in the storage quadrupole. Copyright © 2005 John Wiley & Sons, Ltd. [source] Isomer separation of hyperbranched polyesteramides with gas-phase H/D exchange and a novel MSn approach: DoDIPJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 8 2002Sander Koster Abstract Two approaches are introduced that provide information about the isomeric composition of hyperbranched polyesteramides. The first approach is based on a novel tandem mass spectrometric (MSn) approach that allows the study of different types of isomeric structures by a separation based on their difference in appearance energy. The method is called DoDIP: dissociation of depleted ion populations. A first MS/MS step is used to fragment isomers with relatively low appearance energy. The isomers with higher appearance energy are fragmented in a second MS/MS step of higher energy. The second approach is based on gas-phase H/D exchange experiments that result in a bimodal isotopic distribution for oligomers XnDn+1 of which one distribution corresponds to a type of isomeric structure that exhibits H/D exchange behaviour and the other to an isomeric structure that does not exhibit H/D exchange behaviour. X is a difunctional anhydride of phthalic acid (P), 1,2-cyclohexanedicarboxylic acid (C), succinic acid (S) or glutaric acid (G). D in XnDn+1 is a trifunctional diisopropanolamine and n the degree of polymerization. The type of isomeric structure that does not exhibit H/D exchange behaviour has a non-alternating monomer sequence that contains an amine bond with a relatively high proton affinity. The other isomeric structure that does exhibit H/D exchange behaviour has an alternating monomer sequence containing only amide and ester bonds with relatively low proton affinity. Oligomer structures were confirmed with additional MS2 experiments after H/D exchange. H/D exchange experiments on the fragments obtained after MS2 of the parent ion show that next to previously postulated mechanisms for the cleavage of the ester and amide bond another reaction pathway must be operational. A new mechanism is introduced to explain the H/D exchange behaviour of the fragments that requires a cleavage of the amide bonds only. Two types of fragments are formed by this mechanism. One type is protonated due to the cleavage of the amide bond whereas the other type has an oxazolonium ion structure due to the loss of an additional H2O. Copyright © 2002 John Wiley & Sons, Ltd. [source] Effects of electrospray capillary temperature on amide hydrogen exchangeRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 9 2008Stephen J. Coales Amide hydrogen/deuterium (H/D) exchange coupled with proteolysis, high-perfeomance liquid chromatographic (HPLC) separation and mass spectrometry (MS) has become a powerful tool to study protein dynamics in solution. Prior to the execution of H/D exchange experiments, various experimental parameters have to be set, including proteolysis, HPLC, and MS conditions. Here we investigate the effects of electrospray capillary temperature on deuterium retention in backbone amides of various pepsin-generated cytochrome c peptides. Lower capillary temperature generally helps retain more deuterium than higher capillary temperature. When the capillary temperature was 150°C, on average 26% more deuterium was retained than when the capillary temperature was set at 250°C. The effects of capillary temperature varied depending on the ions monitored. There was little difference in deuterium retention among different charge state species of the same peptide at 150°C. However, a lower charge state ion loses more deuterium atoms going from 150°C to 250°C than the corresponding higher charge state species. These results indicate that the capillary temperature should be optimized not only to maximize the signal-to-noise of each ion followed in H/D exchange experiments, but also to minimize the deuterium loss of the ions. Also the loss of deuterium in several ions, especially lower charge state ones, should be monitored in the optimization, as the temperature effects vary among ions and are more significant for lower charge state ions. Copyright © 2008 John Wiley & Sons, Ltd. [source] Study of Structural Stability of Cyclophilin A by NMR and Circular Dichroism SpectraCHINESE JOURNAL OF CHEMISTRY, Issue 7 2006Yan-Hong Shi Abstract The structural stability of cyclophilin A (CypA) was investigated using H/D exchange and temperature coefficients of chemical shifts of amide protons, monitored by 2D heteronuclear NMR spectroscopy. Amide proton exchange rates were measured by H/D exchange experiments for slow-exchange protons and measured by SEA (Solvent Exposed Amides)-HSQC experiments for fast-exchange protons. Temperature coefficients of chemical shifts and hydrogen exchange rates of amide protons show reasonably good correlation with the protein structure. Totally, 44 out of 153 non-proline assigned residues still exist in 86 d of hydrogen-deuterium exchange at 4 °C, suggesting that CypA structure should be highly stable. Residues in secondary structures of ,2, ,1, ,2, ,5, ,6 and ,7 might constitute the hydrophobic core of the protein. The change in free energy of unfolding (,Gu) of CypA was estimated to be (21.99±1.53) kJ·mol,1 by circular dichroism (CD). The large free energy change is also an indicator of the high structural stability. [source] |