Home About us Contact | |||
Adhesive Materials (adhesive + material)
Selected AbstractsSupramolecular Soft Adhesive MaterialsADVANCED FUNCTIONAL MATERIALS, Issue 11 2010Jérémie Courtois Abstract The rheological and adhesive properties of bis-urea functionalized low-molecular-weight polyisobutylenes (PIBUT) are investigated. The polymers, which can interact through supramolecular hydrogen bonds, can self-organize over times of the order of days at room temperature. This organized structure has been identified by small angle X-ray scattering (SAXS) and its rheological properties indicate the behaviour of a soft viscoelastic gel. The ordered structure can be disrupted by temperature and shear so that at 80,°C, the material behaves as a highly viscoelastic fluid and no SAXS peak is observed. When cooled back at room temperature, the PIBUT retrieves its ordered structure and gel properties after 20 h of annealing. This very slow molecular dynamics gives PIBUT a highly dissipative nature upon deformation, which combined with strongly interacting moieties results in very interesting adhesive properties both on steel surfaces but more importantly on typical low adhesion surfaces such as silicone. A strategy based on the controlled incorporation of supramolecular bonds in a covalently crosslinked network appears promising for the development of a new generation of highly interacting and dissipative soft adhesives. [source] The Influence of Time Interval between Bleaching and Enamel BondingJOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, Issue 2 2007Jéfferson Da Silva Machado dds ABSTRACT Objectives:, The purpose of this study was to investigate the penetration of a conventional adhesive material into enamel bleached with 16% carbamide peroxide and 38% hydrogen peroxide using optical light microscopy. Methods:, Extracted human teeth were randomly divided into eight experimental groups with six specimens each, according to the bleaching material and time interval after bleaching and before the bonding procedure. Groups were designated as follows: control group, restorations in unbleached teeth; restorations performed immediately after bleaching; restorations performed 7 days after bleaching; restorations performed 14 days after bleaching; and restorations performed 30 days after bleaching. The length of resin tags was measured with an Axiophot photomicroscope at 400× magnification for the calculation of the proportion of tags of study groups compared to the respective control groups. Analysis of variance was applied for comparison between groups; data were transformed into arcsine (p < 0.05). Results:, The specimens of experimental groups, in which restorations were performed 7, 14, and 30 days after bleaching, showed better penetration of adhesive material into enamel than specimens restored immediately after bleaching. There was no statistically significant difference between the bleaching materials employed or in the interaction between bleaching agent and time interval. Conclusions:, This suggests that a time interval of at least 7 days should be allowed between enamel bleaching and placement of adhesive bonding agents for accomplishment of composite resin restorations. CLINICAL SIGNIFICANCE Establishment of adequate time after bleaching is fundamental to allow the normal penetration of a one-bottle conventional adhesive onto the enamel surface. [source] Seven-year dentin bond strengths of a total- and self-etch systemEUROPEAN JOURNAL OF ORAL SCIENCES, Issue 3 2005Michael F. Burrow The aim of this study was to determine the durability of tensile bond strengths of a conventional 3-step bonding system (Superbond D-liner Plus) and a self-etching priming bonding system (Clearfil Liner Bond II) to bovine dentin over a 7 yr period. Superficial bovine dentin finished with 600-grit SiC paper was bonded with one of the two adhesive materials. A 4 mm diameter area was bonded, covered with resin composite and stored in 37°C deionized water containing gypsum chips and 0.4% sodium azide as an antibacterial. Bonds were stressed in tension at a crosshead speed of 1 mm min,1. Mean bond strengths were observed at 1 d, at 1, 3, and 6 months, and at 1, 2, 3, 6 and 7 yr. Ten specimens were tested for the first 3 yr and 15 specimens were tested for 6 and 7 yr. The bond strength of Superbond D-liner Plus significantly decreased over the 7 yr period, whereas Liner Bond II showed a slight but, insignificant, decrease. The fracture mode changed with time for Superbond D-liner Plus, but not for Liner Bond II. It was concluded that systems which use a strong acid for demineralizing the dentin may show greater deterioration of the bond to dentin compared with a self-etching priming system. [source] An in vitro comparison of adhesive systems to seal pulp chamber wallsINTERNATIONAL ENDODONTIC JOURNAL, Issue 5 2004B. Ozturk Abstract Aim, To compare in vitro the sealing properties of five different dentine adhesive materials (Prime&Bond NT (PBNT); Prompt L-Pop (PLP); Clearfil SE Bond (CSEB); Scotchbond Multi Purpose Plus (SMPP); EBS-Multi (EBSM)) inside the pulp chamber. Methodology, Seventy-five recently extracted human molar teeth were used. The roof of the pulp chambers and roots were removed under water cooling. Pulp tissue was removed, and the canal orifices were sealed. The pulp chambers were then treated with 5% sodium hypochlorite (NaOCl) for 1 min. The teeth were randomly divided into five groups of 15 teeth each. Adhesive systems were applied to the pulp chamber walls according to the manufacturers' instructions. The samples were connected to Plexiglass plates, and a fluid filtration method was used for quantitative evaluation of leakage. Measurements of fluid movement were made at 2-min intervals for 8 min. The quality of seal of each specimen was measured immediately, after 24 h, 1 week and 1 month. The data were statistically analysed by repeated-measurements multivariate anova, Friedman test, Wilcoxon signed rank test, Kruskal,Wallis of one-way anova and Mann,Whitney U -tests. The pulp chamber wall with and without NaOCl and resin,dentine interfaces of specimens were observed under a scanning electron microscope (SEM). Results, The leakage values of the materials were significantly different at different measurement periods. In all groups, leakage values decreased with time (P < 0.05). PBNT and PLP had the least leakage during immediate measurements (P < 0.05). After 1 month, leakage of all adhesive systems was not significantly different (P < 0.05). SEM observation of pulp chamber walls demonstrated that the irregular dentine surface without smear layer was present in the nontreated group. However, NaOCl application removed the collagen fibrils leaving the dentine surface smooth. At resin,dentine interfaces of specimens, no hybridization zone was observed. Conclusions, None of the materials had created a perfect seal to the pulp chamber walls. PBNT and PLP had better sealing over the short term, but over the long term, there were no differences between the materials. [source] A Prospective Ten-Year Clinical Trial of Porcelain VeneersJOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, Issue 2 2006Article first published online: 25 APR 200 abstract Objective:, The purpose of this prospective clinical study was to evaluate the performance of porcelain veneers after 5 and 10 years of clinical service. Materials and Methods:, A single experienced clinician placed 87 porcelain veneers in 25 patients in 1990 and 1991. The teeth included maxillary central incisors to first premolars. As described in the 5-year report of this study, preparations included a chamfer margin, 0.3 to 0.7 mm labial enamel reduction, and incisal edge coverage. A single laboratory technician fabricated the veneers using feldspathic porcelain on refractory dies. Internal surfaces were etched with 5% hydrofluoric acid and silanated. Teeth were isolated with a rubber dam prior to veneer placement. All veneers were bonded with a light-activated resin cement. Patients were recalled at 5 to 6 years and at 10 years after initial veneer placement. Two evaluators examined each veneer for retention, fractures, color match, surface roughness, marginal adaptation, leakage, recurrent caries, pulp vitality, and patient satisfaction. Marginal adaptation was assessed further using scanning electron microscopy to examine epoxy replicas. Results:, Five years after placement, all 87 veneers remained in place and had "perfect" color match and surface smoothness. Four veneers had fractures, but only one of those required repair. Ninety-nine percent of the veneers had clinically acceptable marginal adaptation, although just 14% of the veneers had "perfect" marginal adaptation at all margins. One had clinically unacceptable staining from leakage. Recurrent caries was present at the proximal margin of two veneers. At the 10-year evaluation, which had a 93% recall rate, color match and surface roughness remained optimal. Thirteen of 22 patients were very satisfied with the esthetic result, whereas 7 complained of minor esthetic problems. The fracture rate increased substantially, to 34% at the 10-year recall. However, only 11% of the fractures were clinically unacceptable. None of the veneers had debonded, but the percentage of veneers with "perfect" marginal adaptation had declined to only 4%. Leakage was now evident around two-thirds of the veneers, and eight restorations had recurrent caries. Conclusion:, Porcelain veneers are a reliable and effective means for conservative esthetic treatment of anterior teeth in the long term. After 10 years of clinical service, esthetic results remained good, patient satisfaction was high, and the retention rate was excellent. The number of irreparable fractures was low. Appropriate preparation design, occlusion, and use of adhesive materials contribute to the ultimate outcome. [source] Click chemistry in materials synthesis.JOURNAL OF POLYMER SCIENCE (IN TWO SECTIONS), Issue 22 2007Abstract 1,2,3-Triazole-based polymers generated from the Cu(I)-catalyzed cycloaddition between multivalent azides and acetylenes are effective adhesive materials for metal surfaces. The adhesive capacities of candidate mixtures of azide and alkyne components were measured by a modified peel test, using a customized adhesive tester. A particularly effective tetravalent alkyne and trivalent azide combination was identified, giving exceptional strength that matches or exceeds the best commercial formulations. The addition of Cu catalyst was found to be important for the synthesis of stronger adhesive polymers when cured at room temperature. Heating also accelerated curing rates, but the maximum adhesive strengths achieved at both room temperature and high temperature were the same, suggesting that crosslinking reaches the same advanced point in all cases. Polytriazoles also form adhesives to aluminum, but copper is bound more effectively, presumably because active Cu(I) ions may be leached from the surface to promote crosslinking and adhesion. © 2007 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 45: 5182,5189, 2007 [source] Microleakage of composite resin restorations in cervical cavities prepared by Er,Cr:YSGG laser radiationAUSTRALIAN DENTAL JOURNAL, Issue 2 2008S Shahabi Abstract Background:, Evaluation of microleakage is important for assessing the success of new methods for surface preparation and new adhesive restorative materials. The aim of this laboratory study was to assess microleakage at the margins of composite restorations in Er,Cr:YSGG laser prepared cavities on the cervical aspects of teeth by means of dye penetration, and compare this with conventionally prepared and conditioned cavities. Methods:, Class V cavities were produced on sound extracted human teeth, which had been assigned randomly to one of three groups (N = 10 each), as follows: Group 1 , prepared using a diamond cylindrical bur and then treated with 37% phosphoric acid; Group 2 , irradiated with an Er,Cr:YSGG laser (Biolase Waterlase) and then treated with 37% phosphoric acid; Group 3 , irradiated only with the laser. After application of bonding agent (Excite, Ivoclar Vivadent), all cavities were restored with composite resin (Heliomolar). After polishing the restorations, the teeth were thermocycled from 5,50°C for 500 cycles. Dye leakage was assessed after immersion in methylene blue, by examining longitudinal sections in a stereomicroscope at ×30 magnification. Results:, The extent of dye penetration was lowest in the laser only group (Group 3). Penetration of dye to dentine and axial walls occurred in 80 per cent of conventionally prepared (bur + acid) specimens, but in the laser group, dye penetration to the axial wall occurred in only 30 per cent of cases. There was a strong statistical association between treatment group and the distribution of microleakage scores (Chi-square, P = 0.0023). Conclusions:, For Class V cavities, with the adhesive materials employed, higher microleakage occurs with phosphoric acid etching of bur- or laser-cut surfaces, than with the surface created by use of the laser alone without additional conditioning. [source] |