High-Density Mapping of Left Atrial Endocardial Activation During Sinus Rhythm and Coronary Sinus Pacing in Patients with Paroxysmal Atrial Fibrillation

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2004
TIMOTHY R. BETTS M.D.
Introduction: This study was designed to record global high-density maps of left atrial endocardial activation during sinus rhythm and coronary sinus pacing. Method and Results: Noncontact mapping of the left atrium was performed in nine patients with paroxysmal atrial fibrillation undergoing pulmonary vein ablation procedures. High-density isopotential and isochronal activation maps were superimposed on three-dimensional reconstructions of left atrial geometry. Mapping was repeated during pacing from sites within the coronary sinus. Earliest left atrial endocardial activation occurred anterior to the right pulmonary veins in seven patients and on the anterosuperior septum in two patients. A line of conduction block was seen in the posterior wall and inferior septum in all patients. The direction of activation in the left atrial myocardium overlying the coronary sinus was different from the electrogram sequence in the coronary sinus catheter in 6 of 9 patients. During coronary sinus pacing, activation entered the left atrium a mean (SD) of 41 (13) ms after the pacing stimulus at a site 12 (10) mm from the endocardium overlying the pacing electrode. Lines of conduction block were present in the posterior wall and inferior septum. Conclusion: In patients with paroxysmal atrial fibrillation, lines of conduction block are present in the left atrium during sinus rhythm and coronary sinus pacing. Electrograms recorded in the coronary sinus infrequently correspond to the direction of activation in the overlying left atrial myocardium. [source]


Electrogram Polarity and Cavotricuspid Isthmus Block During Ablation of Typical Atrial Flutter

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 4 2001
HIROSHI TADA M.D.
Electrogram Polarity in Atrial Flutter Ablation.Introduction: The atrial activation sequence around the tricuspid annulus has been used to assess whether complete block has been achieved across the cavotricuspid isthmus during radiofrequency ablation of typical atrial flutter. However, sometimes the atrial activation sequence does not clearly establish the presence or absence of complete block. The purpose of this study was to determine whether a change in the polarity of atrial electrograms recorded near the ablation line is an accurate indicator of complete isthmus block. Methods and Results: Radiofrequency ablation was performed in 34 men and 10 women (age 60 ± 13 years [mean ± SD]) with isthmus-dependent, counterclockwise atrial flutter. Electrograms were recorded around the tricuspid annulus using a duodecapolar halo catheter. Electrograms recorded from two distal electrode pairs (E1 and E2) positioned just anterior to the ablation line were analyzed during atrial flutter and during coronary sinus pacing, before and after ablation. Complete isthmus block was verified by the presence of widely split double electrograms along the entire ablation line. Complete bidirectional isthmus block was achieved in 39 (89%) of 44 patients. Before ablation, the initial polarity of E1 and E2 was predominantly negative during atrial flutter and predominantly positive during coronary sinus pacing. During incomplete isthmus block, the electrogram polarity became reversed either only at E2, or at neither E1 nor E2. In every patient, the polarity of E1 and E2 became negative during coronary sinus pacing only after complete isthmus block was achieved. In 4 patients (10%), the atrial activation sequence recorded with the halo catheter was consistent with complete isthmus block, but the presence of incomplete block was accurately detected by inspection of the polarity of E1 and E2. Conclusion: Reversal of polarity in bipolar electrograms recorded just anterior to the line of isthmus block during coronary sinus pacing after ablation of atrial flutter is a simple, quick, and accurate indicator of complete isthmus block. [source]


Prevention of the Initiation of Atrial Fibrillation: Mechanism and Efficacy of Different Atrial Pacing Modes

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2000
WEN-CHUNG YU
Several atrial pacing modes have been reported to be effective in the prevention of atrial fibrillation (AF); they included biatrial pacing, dual site right atrial pacing, Bachmann's bundle (BB) pacing, and coronary sinus pacing. However, the relative efficacy and electrophysiological mechanisms of these pacing modes in the prevention of AF are not clear. In 15 patients (age 54 ± 14 years) with paroxysmal AF, P wave duration, effective refractory period, and atrial conduction time were determined with six different atrial drive pacings, that were right atrial appendage (RAA), BB, right posterior interatrial septum (RPS), distal coronary sinus (DCS), RAA plus RPS simultaneously (DSA), and RAA plus DCS simultaneously (BiA). All these patients consistently had AF induced with early RAA extrastimulation coupling to RAA drive pacing. No patient had AF induced with RAA extrastimulation coupled to BB, RPS, or DCS drive pacing, but seven and eight patients had AF induced with RAA extrastimulation coupled to DSA and BiA drive pacing, respectively. The P wave duration was longest during RAA pacing, and became shorter during other atrial pacing modes. Analysis of electrophysiological change showed that early RAA extrastimulation coupled to RAA drive pacing caused the longest atrial conduction delay among these atrial pacing modes; BB, RPS, and DCS drive pacing caused a greater reduction of this conduction delay than DSA and BiA drive pacing. In addition, the effective refractory periods of RAA determined with BB, RPS, and DCS drive pacing were similar and longer than that determined with DSA and BiA drive pacing. In patients with paroxysmal AF, this arrhythmia was readily induced with RAA extrastimuli coupled to RAA drive pacing. BB, RPS, and DCS pacing were similar and more effective than DSA and BiA pacing in preventing AF. [source]