Home About us Contact | |||
Corneal Volume (corneal + volume)
Selected AbstractsDetermination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyesOPHTHALMIC AND PHYSIOLOGICAL OPTICS, Issue 6 2009Alejandro Cerviño Abstract Purpose:, To describe a method to measure corneal volume from topography and pachymetry, and test its clinical use on a sample of healthy human subjects and a case of circumscribed posterior keratoconus. Methods:, Corneal curvature (PCT 200® corneal topography system; Optopol Technology SA, Zawiercie, Poland) and ultrasonic topographic pachometry on 25 points (Ophthasonic® A-Scan/Pachometer III; Teknar Inc., St Louis, MO, USA) were measured on each of 12 young healthy corneas and one cornea suffering from circumscribed posterior keratoconus. Topography and pachymetry data were used to calculate the coordinates for the corresponding points on the posterior surface of the cornea. TableCurve 3D software (Systat Software Inc., Chicago, IL, USA) was used to fit a surface to those points measured. Integration of the surface fitted to the data points, corresponding to the anterior and posterior corneal surfaces, was used to calculate the volume underneath each of them. Subtraction of volumes underneath anterior and posterior surfaces, taking into account an axial offset equal to the central corneal thickness, rendered corneal volume for the central 6 mm of the cornea. Results:, Central corneal thickness ranged from 520 to 630 ,m for the healthy corneas. Corneal volumes for this sample analyzed averaged 18.66 ± 1.15 mm3 (range 17.25,20.53 mm3). For the posterior keratoconic cornea, the affected area was located at about 1.5,2 mm from the corneal center on the 135° hemimeridian of the right eye, observed through topographic pachymetry. Calculated corneal volume for the central 6 mm was 16.072 mm3, noticeably lower than those found in the sample without pathology, but within the range for corneas presenting with keratoconus. Conclusions:, Corneal volume is a useful parameter for characterising dystrophic corneas and can aid in the detection of rare anomalies which are hardly detected with corneal topography and/or central corneal thickness evaluation. A potentially useful measure of corneal volume can be calculated from anterior corneal topography and topographic pachymetry data. Values obtained are in good agreement with previous studies using corneal tomography techniques. The methodology has been shown to have potential for retrospective analysis of data, or where no access is available to tomographical techniques. [source] Evaluation of anterior segment parameter changes using the Pentacam after uneventful phacoemulsificationACTA OPHTHALMOLOGICA, Issue 5 2010Selim Doganay Abstract. Purpose:, This study set out to evaluate the influences of uneventful phacoemulsification on the anterior segment parameters obtained with the Pentacam rotating Scheimpflug camera and intraocular pressure (IOP). Methods:, A total of 42 eyes of 34 patients (26 men, eight women) were evaluated preoperatively, and at 1, 3 and 6 months postoperatively with the Pentacam. Intraocular pressure was measured with the Goldmann applanation tonometer. The non-parametric paired t -test was used to compare preoperative and 1-, 3- and 6-month postoperative measurements of anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) width, central corneal thickness (CCT), the central 3-, 5- and 7-mm corneal volume (CV), pupil size, and IOP. Pearson's correlation test was used to evaluate the relationships between IOP and ACD, ACV and ACA width. Results:, The differences between ACD, ACV, ACA and IOP values taken preoperatively and those taken postoperatively at 1, 3 and 6 months were statistically significant (p < 0.05). The differences between CCT, central 3-, 5- and 7-mm CV, and pupil size measurements taken preoperatively and those taken postoperatively at 1, 3 and 6 months were not statistically significant (p > 0.05). The decrease in IOP was not correlated with the changes in ACD, ACV and ACA (p > 0.05). Conclusions:, Uneventful phacoemulsification significantly reduced IOP, increased ACD and ACV, and widened the ACA. However, alterations in CV, CCT and pupil size values were not statistically significant. Alterations in ACD, ACV, ACA and IOP remain stable after the first month of surgery. [source] |