Home About us Contact | |||
Compression Speed (compression + speed)
Selected AbstractsTEXTURE PROFILE ANALYSIS , HOW IMPORTANT ARE THE PARAMETERS?JOURNAL OF TEXTURE STUDIES, Issue 5 2010ANDREW J. ROSENTHAL ABSTRACT A starch-glycerol gel was subjected to a two-bite compression test using two sample-instrument geometries, various speeds of compression and strain levels, both with lubrication or not. Results were interpreted using the primary characteristic terminology previously defined in Texture Profile Analysis. Compression speeds from 0.1 to 10 m/s showed a logarithmic relationship with hardness, cohesiveness, corrected cohesiveness and adhesiveness. Gels survived compression to strains of 0.90 without failing, strain levels from 0.25 to 0.90 resulted in an exponential rise in hardness with increasing strain and linear reduction in corrected cohesiveness. Lubrication had no significant influence on any of the measured parameters and an application of force with different sample-instrument geometry revealed that parallel plates and plungers only had an influence on gel hardness. Caution is urged when researchers modify the test protocol from 75% deformation with parallel plates. A minimum crosshead speed of 2 mm/s is recommended. PRACTICAL APPLICATIONS Texture Profile Analysis has been widely applied to test solid and semisolid foods; however, some researchers deviate from the original test protocol. This article attempts to show how modifying the parameters in the test protocol can influence the apparent properties of the sample. [source] Relining of prosthesis with auto-polymerizing hard denture reline resins: effect of post-polymerization treatment on flexural strengthGERODONTOLOGY, Issue 3 2009Jessica Mie Ferreira Koyama Takahashi Background:, It has been suggested that microwave irradiation and prosthesis immersion in hot water after its polymerization may improve mechanical and viscoelastic properties of acrylic resins. Purpose:, This study was proposed to verify the influence of microwave post-polymerization (PP) treatment over the flexural strength of thermo-polymerizing acrylic resin specimens (QC-20) relined or not with two different composition hard chairside auto-polymerizing reliners [Kooliner (K) and New Truliner (NT)]. Materials and Methods:, For this study, 50 specimens of 64 × 10 × 3.3 mm were polymerized and distributed into five groups. G1 (control) specimens without relining and PP; G2 specimens relined with K, without PP; G3 specimens relined with NT, without PP; G4 specimens relined with K, with PP (microwave irradiation with 650 W for 5 min); G5 specimens relined with NT, with PP. Tests were performed on a universal testing machine Instron 4411 with compression speed of 5 mm/min. Results:, Specimens of K without PP did not show statistically different results (p < 0.05) when compared with control. However, when submitted to PP these specimens showed a significant increase in flexural strength. Specimens of NT showed the lowest flexural strength of all groups, with or without PP when compared with control and K groups. Conclusion:, Microwave PP (650 W for 5 min) proved to be an effective method of improving the flexural strength of K relined prosthesis. However, it did not seem to affect NT specimens. [source] Simulation of injection-compression molding process, Part 3: Effect of process conditions on part birefringenceADVANCES IN POLYMER TECHNOLOGY, Issue 3 2002Shia-Chung Chen Abstract Simulations of the injection-compression molding (ICM) process based on a Leonov viscoelastic fluid model has been employed to study the effects of processing conditions on the birefringence development and distribution in injection-compression molded parts. A numerical algorithm combined with a modified control-volume/finite-element method is developed to predict the melt front advancement and the distributions of pressure, temperature, and flow velocity dynamically during the injection melt-filling, compression melt-filling, and postfilling stages of the entire process. Part birefringence was then calculated from residual stresses following the thermal-mechanical history of the entire molding process. Simulations of a disk part under different process conditions including compression speed, switch time from injection to compression, compression stroke, packing pressure, and postfilling time were performed to understand their effects on birefringence variation. The simulated results were also compared with those required by conventional injection molding (CIM). It has been found that an ICM part shows a significant reduction of part birefringence near the gate area as compared with CIM parts. However, ICM parts exhibit higher birefringence values near the rim of the disk. The minimum birefringence occurs around the location where injection is switched over to compression. Although longer postfilling time and higher packing pressure result in higher birefringence values, their effects are not very significant. On the other hand, higher compression speed, larger compression stroke, and shorter switch time exhibit greater effects on the increase of part birefringence. Flow-induced residual stress is the major origin of birefringence formation in the present case. The simulated birefringence for both ICM and CIM parts show good coincidence with those obtained from measurements by using a digital photoelasticity technique. © 2002 Wiley Periodicals, Inc. Adv Polym Techn 21: 177,187, 2002; Published online in Wiley Interscience (www.interscience.wiley.com). DOI 10.1002/adv.10024 [source] Evaluation of a rotary tablet press simulator as a tool for the characterization of compaction properties of pharmaceutical productsJOURNAL OF PHARMACEUTICAL SCIENCES, Issue 6 2010F. Michaut Abstract The Stylcam 100R, a rotary press simulator, was designed to simulate speed profiles of rotary tablet presses. Such a simulator was qualified by numerous laboratories and, actually, its ability to be used for studying the behaviour of powders under pressure should be examined. Then, the purpose of this work was to investigate the performances of the Stylcam 100R for characterizing the compaction behaviour and the tabletting properties of pharmaceutical powders. The compressibility of three pharmaceutical excipients (microcrystalline cellulose, dicalcium phosphate dihydrate and ,-lactose monohydrate) was studied. Four compression speeds were used on the compaction simulator. Force,displacement cycles were associated with two energy parameters, the specific total energy (Estot) and the specific expansion energy (Esexp). The mean yield pressure was calculated from Heckel's plots obtained with the in-die method. The diametral tensile strength of compacts was measured in order to evaluate mechanical properties. To evaluate the accuracy of all these parameters, a comparative study was carried out on an eccentric instrumented press. The values of energy parameters and tensile strengths of tablets are close between the eccentric press and the compaction simulator, whatever the compression speed on the latter. The mean yield pressure values obtained using the two presses are different. Finally, the Stylcam 100R seems to be a good tool for characterising tabletting properties of powders, except for the Heckel's model probably due to an unadapted equation of deformation and a lack of accuracy of the displacement transducers. Future improvements should allow correcting these two points. © 2009 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 99: 2874,2885, 2010 [source] |