| |||
Acrylic Teeth (acrylic + tooth)
Selected AbstractsBonding acrylic teeth to acrylic resin denture bases: a reviewGERODONTOLOGY, Issue 3 2006S. B. Patil Partial or complete dentures are more commonly constructed for the elderly group of the population. Teeth debonding from the dentures can be frustrating to the patients as well as the dentist. Research has been carried out and is continuing to study the issue of bonding acrylic teeth to the denture base resin. The present review takes into account the majority of research papers published in the last five decades for determining the bond strength. Selection of more compatible combinations of denture base resins and acrylic teeth may reduce the number of prosthesis fractures and the resultant repairs. [source] Evaluation of the Bond Strength of Denture Base Resins to Acrylic Resin Teeth: Effect of ThermocyclingJOURNAL OF PROSTHODONTICS, Issue 5 2009Julię Marra DDS Abstract Purpose: The purpose of this study was to evaluate the thermocycling effects and shear bond strength of acrylic resin teeth to denture base resins. Materials and Methods: Three acrylic teeth (Biotone, Trilux, Ivoclar) were chosen for bonding to four denture base resins: microwave-polymerized (Acron MC), heat-polymerized (Lucitone 550 and QC-20), and light-polymerized (Versyo.bond). Twenty specimens were produced for each denture base/acrylic tooth combination and were divided into two groups (n = 10): without thermocycling (control groups) and thermocycled groups submitted to 5000 cycles between 4 and 60°C. Shear strength tests (MPa) were performed with a universal testing machine at a crosshead speed of 1 mm/min. Statistical analysis of the results was carried out with three-way ANOVA and Bonferroni's multiple comparisons post hoc analysis for test groups (,= 0.05). Results: The shear bond strengths of Lucitone/Biotone, Lucitone/Trilux, and Versyo/Ivoclar specimens were significantly decreased by thermocycling, compared with the corresponding control groups (p < 0.05). The means of Acron/Ivoclar and Lucitone/Ivoclar specimens increased after thermocycling (p < 0.05). The highest mean shear bond strength value was observed with Lucitone/Biotone in the control group (14.54 MPa) and the lowest with QC-20/Trilux in the thermocycled group (3.69 MPa). Conclusion: Some acrylic tooth/denture base resin combinations can be more affected by thermocycling; effects vary based upon the materials used. [source] Five-year results of fixed implant-supported rehabilitations with distal cantilevers for the edentulous mandibleCLINICAL ORAL IMPLANTS RESEARCH, Issue 6 2009German O. Gallucci Abstract Objectives: The purpose of this study was to evaluate the survival rate, success rate and primary complications associated with mandibular fixed implant-supported rehabilitations with distal cantilevers over 5 years of function. Material and methods: In this prospective multi-center trial, 45 fully edentulous patients were treated with implant-supported mandibular hybrid prostheses with distal extension cantilevers. Data were collected at numerous time points, including but not limited to: implant placement, abutment placement, final prosthesis delivery, 3 months and 5 years post-loading. Biological, implant and prosthetic parameters defining survival and success were evaluated for each implant including: sulcus bleeding ndex (SBI) at four sites per implant, width of facial and lingual keratinized gingiva (mm), peri-implant mucosal level (mid-facial from the top of the implant collar, measured in mm), modified plaque index (MPI) at four sites per implant, mobility and peri-implant radiolucency. Survival was defined as implants or prostheses that did not need to be replaced. Success rate was defined as meeting well-established criteria that were chosen to indicate healthy peri-implant mucosa osseointegration, prostheses success and complications. Results: A total of 237 implants in 45 completely edentulous patients were included in the study. In each patient, four to six implants were placed to support hybrid prostheses with distal cantilevers. Cantilevers ranged in length from 6 to 21 mm, with an average length of 15.6 mm. The ages of the patients ranged from 34 to 78 with a mean age of 59.5 years. The survival rate of implants was 100% (237/237) and for prostheses 95.5% (43/45). The overall treatment success rate was calculated as 86.7% (39/45). Of the six patients that have not met the criteria for success, two patients required replacement of the entire prosthesis and four patients presented >four complications events. Conclusion: Fixed implant-supported rehabilitation with distal cantilever resulted in a reliable treatment modality over the 5-year observation period. Although biological parameters of MPI, SBI, keratinized tissue and peri-implant mucosal levels showed statistically significant differences over time, the mean values for each patient remained within the normal limits of oral health. Complications were categorized as biological or technical. The majority of complications were technical complications (54/79) and of these most involved fracture of the acrylic teeth and base (20/54). While the survival rate was 100% for implants and 95.5% for prostheses, the application of strict criteria for treatment success resulted in an overall treatment success rate of 86.7%. [source] |