Use of Process Data To Assess Chromatographic Performance in Production-Scale Protein Purification Columns

BIOTECHNOLOGY PROGRESS, Issue 2 2003
Tina M. Larson
Transition analysis was performed on production-scale chromatography data in order to monitor column performance. Analysis of over 300 transitions from several different chromatography operations demonstrated the utility of the techniques presented. Several of the transitions analyzed occurred on columns with known integrity breaches. The techniques proved sensitive for detection of these breaches. Seven transition calculations are presented, which were combined to produce a single overall integrity value for each column. In addition, principal components analysis (PCA) was used to detect shifts in the transition pattern, including those attributed to integrity breaches. Besides detection of integrity breaches, transition analysis proved useful in monitoring column efficiency over multiple column uses. [source]


High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry

ELECTROPHORESIS, Issue 21 2003
Alexander R. Ivanov
Abstract High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 ,m inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n -propanol and formamide as porogens and azobisisobutyronitrile as initiator. N -Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300,000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method. [source]


Rapid screening and characterization of drug metabolites using a new quadrupole,linear ion trap mass spectrometer

JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 2 2003
Gérard Hopfgartner
Abstract The application of a new hybrid RF/DC quadrupole,linear ion trap mass spectrometer to support drug metabolism and pharmacokinetic studies is described. The instrument is based on a quadrupole ion path and is capable of conventional tandem mass spectrometry (MS/MS) as well as several high-sensitivity ion trap MS scans using the final quadrupole as a linear ion trap. Several pharmaceutical compounds, including trocade, remikiren and tolcapone, were used to evaluate the capabilities of the system with positive and negative turbo ionspray, using either information-dependent data acquisition (IDA) or targeted analysis for the screening, identification and quantification of metabolites. Owing to the MS/MS in-space configuration, quadrupole-like CID spectra with ion trap sensitivity can be obtained without the classical low mass cutoff of 3D ion traps. The system also has MS3 capability which allows fragmentation cascades to be followed. The combination of constant neutral loss or precursor ion scan with the enhanced product ion scan was found to be very selective for identifying metabolites at the picogram level in very complex matrices. Owing to the very high cycle time and, depending on the mass range, up to eight different MS experiments could be performed simultaneously without compromising chromatographic performance. Targeted product ion analysis was found to be complementary to IDA, in particular for very low concentrations. Comparable sensitivity was found in enhanced product ion scan and selected reaction monitoring modes. The instrument is particularly suitable for both qualitative and quantitative analysis. Copyright © 2003 John Wiley & Sons, Ltd. [source]


Mobile phase additives for enhancing the chromatographic performance of astaxanthin on nonendcapped polymeric C30 -bonded stationary phases

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 1 2009
Philipp Kaiser
Abstract Astaxanthin shows peak deformation and reduced peak area response when eluted with methanol and methyl tert -butyl ether on nonendcapped polymeric C30 -bonded HPLC phases. The present study tested different column manufacturers, column batches, and ten mobile phase additives including acids, bases, buffers, complexing and antioxidant agents for improvement of peak shape and peak area response. Concerning chromatographic benefits and feasibility, ammonium acetate was found to be the best additive followed by triethylamine for all columns tested. Variation of the mobile phase pH equivalent and the column temperature showed no synergistic effects on peak shape and peak area response. Results indicate that peak tailing and variation of peak area response are due to different on-column effects. Possible mechanisms of the observed phenomenon will be discussed. [source]


The application of small porous particles, high temperatures, and high pressures to generate very high resolution LC and LC/MS separations

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 8 2007
Robert Plumb
Abstract The effect of combining sub-2 ,m porous particles with elevated operating temperatures on chromatographic performance has been investigated in terms of chromatographic efficiency, productivity, peak elution order, and observed operating pressure. The use of elevated temperature in LC does not increase the obtainable performance but allows the same performance to be obtained in less time. Increasing the column temperature did allow the use of longer columns, generating column efficiencies in excess of 100 000 plates and gradient peak capacities approaching 1000. Raising the temperature increased the optimal mobile phase linear velocity, negating somewhat the pressure benefits observed by reducing the solvent viscosity. When operating at higher temperature the analyte retention is not only reduced, but the order of elution will also often change. High temperature separations allowed exotic organic modifiers such as isopropanol to be exploited for alternative selectivity and faster analysis. Finally, care must be taken when using high temperature separations to ensure that the narrow peak widths produced do not compromise the quality of data obtained from detectors such as high resolution mass spectrometers. [source]


The detection of phenotypic differences in the metabolic plasma profile of three strains of Zucker rats at 20 weeks of age using ultra-performance liquid chromatography/orthogonal acceleration time-of-flight mass spectrometry

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 19 2006
Robert S. Plumb
Analysis of biological fluids using ultra-performance liquid chromatography/mass spectrometry (UPLC/MS) (metabonomics) can allow new insights to be gained into disease processes, with advances in chromatographic techniques enabling the detection of thousands of metabolites. In this work metabonomics has been used to investigate the metabolic processes involved in type II diabetes in the Zucker obese rat. Plasma was analyzed from three different strains, the Zucker (fa/fa) obese, Zucker lean and the lean/(fa) obese cross. Using UPLC/MS, ca. 10,000 ions were detected due to the narrow peak widths and excellent peak shapes achieved with this technology. Confidence in the chromatographic performance was demonstrated by the use of quality control standards. The positive and negative ion total ion chromatograms obtained from the three strains were readily distinguishable using multivariate statistical analysis. The greatest difference was observed between the Zucker lean and Zucker lean/(fa) rats compared to the Zucker (fa/fa) obese rats. Positive ions m/z 220 (4.36,min), 282(3.78,min), 359 (5.33,min) and 405 (7.77,min) were elevated in the plasma derived from Zucker lean rats whilst ions m/z 385 (6.80,min) and 646 (4.36,min) were at a lower concentration compared to the plasma from the Zucker (fa/fa) obese animals. Negative ions elevated in the Zucker lean rats included m/z 212 (2.30,min), 514 (2.85,min), 295 (4.39,min), 329 (3.11,min), 343 (2.86,min) and 512 (2.86,min) with ions m/z 538 (4.18,min), 568 (4.18,min), 568 (5.09,min) and 612 (4.30,min) being raised in the samples derived from Zucker (fa/fa) obese animals. The ion m/z 514 (3.85,min) was found to correspond to taurocholate, providing further support for an involvement of taurine metabolism in diabetes. Copyright © 2006 John Wiley & Sons, Ltd. [source]


Fast analysis in liquid chromatography using small particle size and high pressure

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 12 2006
Dao T.-T.
Abstract In order to enhance chromatographic performances in terms of efficiency and rapidity, LC has recently evolved in the development of short columns packed with small particles (sub-2 ,m) working at high pressures (>400 bar). This approach has been described 30 years ago according to the fundamental chromatographic equations. However, systems and columns compatible with such high pressures have been introduced in the market in 2004 only. Advantages of small particles working at high pressure will be discussed in terms of sensitivity, efficiency, resolution, and analysis time. Potential problems encountered with high pressure in terms of frictional heating and solvent compressibility will also be discussed even if systems working at a maximum pressure of 1000 bar are not influenced by these parameters and give reliable and reproducible results. Several applications will highlight the potential and interest of this new technology. [source]